DSCover Satellite Products SCW904x manual First System Options, Second System Options

Page 39

Section 8: Programming Descriptions

Section [013] First System Options

Option Description

[1]ON: Hardwired Zone 33 enabled. OFF: PGM1 Output enabled. Program Zone Definition or PGM option in Section [009]

[2]ON: Hardwired Zone 34 enabled. OFF: PGM2 Output enabled. Program Zone Definition or PGM option in Section [009]

[3]-[5] Future Use

[6]ON: Audible Exit Fault Enabled. If a delay zone is not secured correctly and not force-armed, at the end of the exit delay, the

system will go into entry delay and turn ON the bell output. OFF: Audible Exit Fault Disabled. The keypad will sound the entry delay through the keypad.

[7]ON: Event Buffer Follows Swinger Shutdown. The system will NOT log additional alarms for a zone that has reached the swinger

shutdown threshold. OFF: Event Buffer Logs Past Shutdown. All zone alarms will be logged.

[8]ON: Temporal Three Fire Signal Enabled. Temporal Three Fire Signal is used to annunciate fire alarms

(½ second ON, ½ second OFF, ½ second ON, ½ second OFF, ½ second ON, 1 ½ seconds OFF). OFF: Standard Pulsed Fire Signal. The system will pulse the bell output

(1 second ON, 1 second OFF).

Section [014] Second System Options

Option Description

[1]ON: Arm/Disarm Bell Squawk Enabled. The system squawks the bell output once when the system is armed, twice when disarmed

and 3 times when disarming with alarms in memory. OFF: Arm/Disarm Bell Squawk Disabled. The bell output does not activate.

[2]Future Use:

[3]ON: RF Jam Logs after 5 Minutes. The system logs an RF Jam trouble condition if the condition is present for 5 minutes. OFF: RF Jam Logs after 20 Seconds. The system logs the trouble condition after 20 seconds.

[4]ON: Aux Boost Enabled: When the system is in Power Save mode (AC Trouble) Aux+ output voltage is regulated 12VDC.

OFF: Aux Boost Disabled: Aux+ output voltage is not regulated.

[5]Future Use

[6]ON: Audible Exit with Urgency. The system will beep the keypad once every second, and 3 times a second during the last 10 seconds, during exit delay when the system is armed with a user code or armed in the Away mode.

OFF: Silent Exit Delay. The keypad will not beep.

[7]Future Use:

[8]ON: Fire Bell is Continuous. The bell output will not time out if a fire alarm occurs. The User must turn off the bell by entering a valid user code.

OFF: Fire Bell follows Bell Cut-off.The bell output will time out normally.

Section [015] Third System Options

Option Description

[1]ON: [F] Key Enabled. The keypad [F] fire emergency key will be enabled.

OFF: [F] Key Disabled. The keypad [F] fire emergency key will be disabled.

[2]ON: [P] Key Audible (Bell/Beeps). The keypad [P] panic emergency will generate 3 ack beeps and the bell will activate for the duration of the BTO or until a code is entered. (The keypad will display “system in alarm”.)

OFF: [P] Key Silent. The keypad [P] emergency key generate a silent panic alarm. The bell will not sound and the keypad will not display “system in alarm”.

[3]ON: Quick Exit Enabled. the Quick Exit feature will be enabled.

OFF: Quick Exit Disabled. the Quick Exit feature will be disabled.

[4]

ON: Quick Arming Enabled. The Quick Arming [ ][0] feature will be enabled.

 

OFF: Quick Arming Disabled. Quick Arming [ ][0] feature will be disabled.

If this feature is disabled, a valid user code must be entered after the Stay or Away function buttons are pressed.

[5]

ON: Code Required for Bypassing. A valid user code must be entered after pressing [ ][1] to access the Bypass feature.

 

OFF: No Code Required. A user code is not required for bypassing.

[6]Future Use

[7]ON: TLM Enabled. The system supervises the telephone line and displays a trouble if disconnected.

OFF: TLM Disabled. The telephone line is not supervised.

WWW.DIYALARMFORUM.COM35

Image 39
Contents Installation Guide Before Installing The Equipment Selecting a Suitable Location For The Alarm ControllerSafety Precautions required during Installation Table of Contents Page Technical Summary Installation & WiringEnsure connector key is oriented correctly InstallationWiring Burglary Zone Wiring ChartMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Verify Device Electronic Serial Number ESN Wireless Device EnrollmentEnter Wireless Enrollment Mode Activate Wireless DeviceZone Dependant Devices Detectors Zone Definitions Options 1 Template ProgrammingDigit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out Local Programming with PC-Link New Installations Refer to .1 Installation onExisting Installations Refer to .1 Installation on DLS ProgrammingOperation Program User Codes Alarm Memory DisplayDoor Chime Enable/Disable Trouble Display9User Code No-Entry Arming 7x Command Outputs 1&2Installer Programming Additional Keypad FunctionsAdvanced Programming Index to Programming Work Sheets and Descriptions Programming Work SheetsZone Definitions Programming WorksheetsFunction Key Programming Function Key OptionsKeypad Lockout Options Installer’s Code Master CodeSystem Times 009 I/O ProgrammingTenth System Options Second System OptionsThird System Options Fourth System OptionsZone Attributes Options 10-13 are reserved for Future Use Zone Loop Response OptionsNo Activity Arming Timer PGM Output TimerCross Zone/Police Code Timer No Activity Arming Pre-alert TimerPriority Alarm and Restoral Reporting Codes Alarm Reporting Codes, ZonesAlarm Restoral Reporting Codes, Zones Miscellaneous Alarm Reporting CodesTamper Reporting Codes, Zones Tamper Restoral Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Tamper/Restore Communicator Call Directions Communicator Format OptionsOpening/Closing Communicator Call Directions Test Transmission Time of Day System Maintenance Communicator Call DirectionsSystem Test Transmissions Communicator Call Directions Communication VariablesSecond Communicator Options Third Communicator OptionsDownloading Options Attribute Number of Rings To Answer OnInitiate PC-Link Downloading PGM Output AttributesFirst International Options Automatic Clock AdjustDelay Between Dialing Attempts 600 2-way Audio Control Options Applies to SCW9047 onlyWireless Supervisory Window Wireless programming Wireless Zone ProgrammingRestore Wireless Device Default Programming General Wireless OptionsWireless Module Placement Test Installer Lockout Enable Installer Lockout DisableLabel Programming Zone Local Keypad ProgrammingCommand Output #2 Label Fire Alarm LabelAlarm When Armed Event Message Command Output #1 LabelThird Keypad Options Reset Programmable Labels to Factory DefaultsFirst Keypad Options Second Keypad OptionsProgramming Descriptions Keypad Function Key Programming002 Zone Definitions O Programming Zones/PGMs Installer CodeSystem Times Master CodeFirst System Options Second System OptionsThird System Options Fourth System Options Tenth System OptionsOFF Keypad Always Active. The keypad does not blank Standard Time Set Clock Back Zone Loop Response Options134 Zone Attributes Daylight Saving Time Move Clock AheadCall Waiting Cancel String PGM Output TimerCross Zone/Police Code Timer No Activity Arm TimerCommunicator Variables Test Transmission TimeFirst Communicator Options First Downloading Options OFF Closing Confirmation Disabled. The keypad does not beepSecond Communicator Options Third Communicator OptionsNumber of Rings to Answer On Downloading Access CodeDownloading Computer Phone Number Panel Identification CodeAutomatic Clock Adjust Way Audio Control Options applies to SCW9047 onlyFollowing attributes are available for PGM Output Type Second International Options Delay Between Dialing AttemptsWireless Programming First International OptionsRestore Wireless Device Default Programming Wireless Module Placement TestInstaller Lockout Enable Installer Lockout DisableKeypad Programming Fire Alarm LabelsAlarm when Armed Event Message 069 Command Output LabelOption Description Future Use OFF Power LED is disabled. Option 6 has no effectFirst Keypad Options Second Keypad OptionsProgrammed LCD Message Duration Label ResetThird Keypad Options Programmed LCD MessageTesting & Troubleshooting Trouble 8 Loss of Clock/Date Trouble 4 Failure to CommunicateContact ID Appendix a Reporting Code FormatsSIA Format Automatic Zone Alarm/Restoral Codes Contact ID Zone Alarm/Restoral Event CodesAppendix B Communicator Format Options Residential Dial PagerNorth America Appendix C Regulatory Approvals InformationSIA False Alarm Reduction Installations EuropeNew Zealand Exit Time Appendix D SIA False Alarm ReductionFormat Reporting Code/Event Appendix E 2-Way Audio Verification SCW9047 onlyBell/Buzzer Silent During 2-Way Audio Key Command DescriptionVOX Support Hang-up Auto-detectionPage FCC Compliance Statement