DSCover Satellite Products SCW904x Programming Descriptions, Keypad Function Key Programming

Page 37

Section 8: Programming Descriptions

Section 8: Programming Descriptions

The following is a brief description of the features and options available in the control panel.

Section [000] Keypad Function Key Programming

The five function keys can be reprogrammed with following functions. See Keypad Function Key Programming on page 16 for defaults

Option

Description

 

Option

Description

[00]

Null Key: Program non functioning keys with this option

[14]

Command Output #2: See [ ][7][1] on page 13

[03]

Stay Arm: See Stay Arm on page 11

[16]

Quick Exit: See [ ][0] on page 13

[04]

Away Arm: See Away Arm on page 11

[17]

Reactivate Stay/Away Zones: See [ ][1] on page 11

[05]

No Entry Arm: See [

][9] on page 13

*[27]

Disarm: See Disarm on page 11

[06]

Chime On/Off: See [

][4] on page 12

*[29]

[A]ux Alarm: Same as [A] key

[08]

Bypass: See [ ][1] on page 11

*[30]

[P]anic: Same as [P] key.

[13]

Command Output #1: See [ ][7][1] on page 13

*Applies to Key Fobs only (See Section [804] Subsection [61]-[76]

Section [001]-[002] Zone Definitions

Option Description

[00]Null Zone: Zone not used

[01]Delay 1: When armed, provides entry delay when violated (follows Entry Delay 1)

[02]Delay 2: When armed, provides entry delay when violated (follows Entry Delay 2)

[03]Instant: When armed, instant alarm when violated

[04]Interior: When armed, instant alarm if the zone is violated first, will follow entry delay if entry delay is active

[05]Interior Stay/Away: Similar to ‘Interior’ except panel will auto-bypass the zone if armed in the Stay mode

[06]Delay Stay/Away: Similar to ‘Delay 1’ except panel will auto-bypass the zone if armed in the Stay mode

[07]-[08]

Future Use

[09]24-Hour Supervisory (Hardwired): Instant Alarm, silent at default.

[10]24-Hour Supervisory Buzzer: Instant alarm, panel will activate keypad buzzer instead of bell output

[11]24-Hour Burglary: Instant alarm when violated, audible alarm at default.

[12]Future Use

[13]24-Hour Gas: Instant alarm when violated, audible alarm at default.

[14]24-Hour Heat: Instant alarm when violated, audible alarm at default (also known as high-temp).

[15]24-Hour Medical: Instant alarm when violated, audible alarm at default.

[16]24-Hour Panic: Instant alarm when violated, audible alarm at default.

[17]24-Hour Emergency: Instant alarm when violated, audible alarm at default.

[18]Future Use

[19]24-Hour Water: Instant alarm when violated, audible alarm at default (also known as flood).

[20]24-Hour Freeze: Instant alarm when violated, audible alarm at default (also known as low-temp).

[21]Future Use

[22]Momentary Keyswitch Arm: Arms or disarms the system when violated

[23]Maintained Keyswitch Arm: Arms system when violated, disarms system when restored

[24]For Future Use

[25]Interior/Delay: Function as an Interior zone when armed in Away mode, and as a Delay zone when armed in the Stay mode

[26]24-HourNon-Alarm:Zone will NOT create an alarm. Can be used with chime to identify a specific event.

[27]-[31]

Future Use:

[32]Instant Stay/Away: Similar to ‘Instant’ except panel will auto-bypass the zone if armed in the Stay mode

[33]-[35]

Future Use

[36]24-HourNon-Latching Tamper: Instant tamper condition when violated. Active in armed and disarmed state.

WWW.DIYALARMFORUM.COM33

Image 37
Contents Installation Guide Selecting a Suitable Location For The Alarm Controller Before Installing The EquipmentSafety Precautions required during Installation Table of Contents Page Technical Summary Installation & WiringEnsure connector key is oriented correctly InstallationBurglary Zone Wiring Chart WiringMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Enter Wireless Enrollment Mode Wireless Device EnrollmentActivate Wireless Device Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Zone Definitions Options 1 Template ProgrammingDigit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out Existing Installations Refer to .1 Installation on New Installations Refer to .1 Installation onDLS Programming Local Programming with PC-LinkOperation Door Chime Enable/Disable Alarm Memory DisplayTrouble Display Program User CodesInstaller Programming 7x Command Outputs 1&2Additional Keypad Functions 9User Code No-Entry ArmingAdvanced Programming Index to Programming Work Sheets and Descriptions Programming Work SheetsFunction Key Programming Programming WorksheetsFunction Key Options Zone DefinitionsSystem Times Installer’s Code Master Code009 I/O Programming Keypad Lockout OptionsThird System Options Second System OptionsFourth System Options Tenth System OptionsZone Attributes Options 10-13 are reserved for Future Use Zone Loop Response OptionsCross Zone/Police Code Timer PGM Output TimerNo Activity Arming Pre-alert Timer No Activity Arming TimerAlarm Restoral Reporting Codes, Zones Alarm Reporting Codes, ZonesMiscellaneous Alarm Reporting Codes Priority Alarm and Restoral Reporting CodesTamper Restoral Reporting Codes, Zones Tamper Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Communicator Format Options Tamper/Restore Communicator Call DirectionsOpening/Closing Communicator Call Directions System Test Transmissions Communicator Call Directions System Maintenance Communicator Call DirectionsCommunication Variables Test Transmission Time of DayThird Communicator Options Second Communicator OptionsDownloading Options Initiate PC-Link Downloading Number of Rings To Answer OnPGM Output Attributes AttributeDelay Between Dialing Attempts Automatic Clock Adjust600 2-way Audio Control Options Applies to SCW9047 only First International OptionsWireless Supervisory Window Wireless programming Wireless Zone ProgrammingWireless Module Placement Test Installer Lockout Enable General Wireless OptionsInstaller Lockout Disable Restore Wireless Device Default ProgrammingLabel Programming Zone Local Keypad ProgrammingAlarm When Armed Event Message Fire Alarm LabelCommand Output #1 Label Command Output #2 LabelFirst Keypad Options Reset Programmable Labels to Factory DefaultsSecond Keypad Options Third Keypad OptionsKeypad Function Key Programming Programming Descriptions002 Zone Definitions System Times Installer CodeMaster Code O Programming Zones/PGMsSecond System Options First System OptionsThird System Options Tenth System Options Fourth System OptionsOFF Keypad Always Active. The keypad does not blank 134 Zone Attributes Zone Loop Response OptionsDaylight Saving Time Move Clock Ahead Standard Time Set Clock BackCross Zone/Police Code Timer PGM Output TimerNo Activity Arm Timer Call Waiting Cancel StringTest Transmission Time Communicator VariablesFirst Communicator Options Second Communicator Options OFF Closing Confirmation Disabled. The keypad does not beepThird Communicator Options First Downloading OptionsDownloading Computer Phone Number Downloading Access CodePanel Identification Code Number of Rings to Answer OnWay Audio Control Options applies to SCW9047 only Automatic Clock AdjustFollowing attributes are available for PGM Output Type Wireless Programming Delay Between Dialing AttemptsFirst International Options Second International OptionsInstaller Lockout Enable Wireless Module Placement TestInstaller Lockout Disable Restore Wireless Device Default ProgrammingAlarm when Armed Event Message Fire Alarm Labels069 Command Output Label Keypad ProgrammingFirst Keypad Options OFF Power LED is disabled. Option 6 has no effectSecond Keypad Options Option Description Future UseThird Keypad Options Label ResetProgrammed LCD Message Programmed LCD Message DurationTesting & Troubleshooting Trouble 8 Loss of Clock/Date Trouble 4 Failure to CommunicateContact ID Appendix a Reporting Code FormatsSIA Format Automatic Zone Alarm/Restoral Codes Contact ID Zone Alarm/Restoral Event CodesAppendix B Communicator Format Options Residential Dial PagerNorth America Appendix C Regulatory Approvals InformationEurope SIA False Alarm Reduction InstallationsNew Zealand Exit Time Appendix D SIA False Alarm ReductionFormat Reporting Code/Event Appendix E 2-Way Audio Verification SCW9047 onlyVOX Support Key Command DescriptionHang-up Auto-detection Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement