DSCover Satellite Products SCW904x Downloading Computer Phone Number, Downloading Access Code

Page 45

 

Section 8: Programming Descriptions

[4]

ON: User Initiated Call-up Enabled. The user can initiate a downloading session using the [ ][6] command. OFF: User Initiated

 

Call-up Disabled. The user cannot initiate a downloading session.

[5]Future Use

[6]ON: 300 Baud Panel Call-Up.When the user initiates a DLS connection, the panel will connect and send the initial header at 300

baud. OFF: 110 Baud Panel Call-Up.When the user initiates a DLS connection, the panel will connect and send the initial header at 110 baud. The panel will then switch to 300 baud in order to receive the response from the DLS computer.

[7]-[8] Future Use

Section [402] Downloading Computer Phone Number

The Downloading Computer Telephone Number is used for Call Back and User Initiated DLS functions. Program the phone number as required. HEX digits can be included for special applications:

HEX [A]

Not used

HEX [B]

Simulates a [ ] key press

HEX [C]

Simulates a [#] key press

HEX [D]

Additional dial tone search

HEX [E]

2-second pause

HEX [F]

End of phone number marker

Section [403] Downloading Access Code

Program the 6-digit Downloading Access Code. Upon connection, the system will only connect to the downloading computer if the Downloading Access Code programmed matches the Downloading Access Code programmed in the computer file.

Section [404] Panel Identification Code

Program the 6-digit Panel Identification Code. This code is used by the downloading computer to verify the correct account is calling back (Call Back feature) or to identify which customer account file should be used (User Initiated DLS features).

Section [406] Number of Rings to Answer On

The value in this section determine how many rings that the panel will automatically pick up on in order to establish a DLS connection. Default value is 000 rings. Valid entries are [000]-[009].

If Section [401] Option 1 and Section [406] are both enabled, either one will work depending on how the installer calls the premises.

Section [499] Initiate PC-Link Downloading

Enter the following command to initiate downloading via PC-Link – Section [499] [Installer Code] [499]. Plugging in the PC-Link connec- tor will automatically initiate the connection if DLS is initiated before connecting the PC-Link Header. The session will NOT be automati- cally initiated if the system is in installer mode.

Section [501]-[502] PGM 1 & 2 Output Attributes

Allows the user to customize PGM1 and PGM2 Attributes. The following attributes can be enabled or disabled for each PGM output. When a PGM option is changed, the corresponding PGM’s attributes are defaulted.

The following attributes are available for PGM Output Types [01], [05]-[08] and [17]-[20]. Option Description

[1]-[2] Not Used

[3]ON: True Output. Output will activate (switch to ground) when the event occurs.

OFF: Inverted Output. Output will de-activate (switch to open) when the event occurs.

This attribute is also available for PGM Output Types [11] and [12].

[4]ON: Output Pulsed. The output will activate for the duration programmed in the PGM Output Timer, Section [170].

OFF: Output On/Off. The output will toggle between on and off when the corresponding [*][7] command is entered.

This attribute is available only for PGM Output Types [11] and [19]-[20].

[5]ON: Access Code Required for Activation. OFF: No Access Code Required for Activation.

This attribute is available only for PGM Output Types [19]-[20].

WWW.DIYALARMFORUM.COM41

Image 45
Contents Installation Guide Before Installing The Equipment Selecting a Suitable Location For The Alarm ControllerSafety Precautions required during Installation Table of Contents Page Technical Summary Installation & WiringEnsure connector key is oriented correctly InstallationWiring Burglary Zone Wiring ChartMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Enter Wireless Enrollment Mode Wireless Device EnrollmentActivate Wireless Device Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Zone Definitions Options 1 Template ProgrammingDigit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out Existing Installations Refer to .1 Installation on New Installations Refer to .1 Installation onDLS Programming Local Programming with PC-LinkOperation Door Chime Enable/Disable Alarm Memory DisplayTrouble Display Program User CodesInstaller Programming 7x Command Outputs 1&2Additional Keypad Functions 9User Code No-Entry ArmingAdvanced Programming Index to Programming Work Sheets and Descriptions Programming Work SheetsFunction Key Programming Programming WorksheetsFunction Key Options Zone DefinitionsSystem Times Installer’s Code Master Code009 I/O Programming Keypad Lockout OptionsThird System Options Second System OptionsFourth System Options Tenth System OptionsZone Attributes Options 10-13 are reserved for Future Use Zone Loop Response OptionsCross Zone/Police Code Timer PGM Output TimerNo Activity Arming Pre-alert Timer No Activity Arming TimerAlarm Restoral Reporting Codes, Zones Alarm Reporting Codes, ZonesMiscellaneous Alarm Reporting Codes Priority Alarm and Restoral Reporting CodesTamper Reporting Codes, Zones Tamper Restoral Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Tamper/Restore Communicator Call Directions Communicator Format OptionsOpening/Closing Communicator Call Directions System Test Transmissions Communicator Call Directions System Maintenance Communicator Call DirectionsCommunication Variables Test Transmission Time of DaySecond Communicator Options Third Communicator OptionsDownloading Options Initiate PC-Link Downloading Number of Rings To Answer OnPGM Output Attributes AttributeDelay Between Dialing Attempts Automatic Clock Adjust600 2-way Audio Control Options Applies to SCW9047 only First International OptionsWireless Supervisory Window Wireless programming Wireless Zone ProgrammingWireless Module Placement Test Installer Lockout Enable General Wireless OptionsInstaller Lockout Disable Restore Wireless Device Default ProgrammingLabel Programming Zone Local Keypad ProgrammingAlarm When Armed Event Message Fire Alarm LabelCommand Output #1 Label Command Output #2 LabelFirst Keypad Options Reset Programmable Labels to Factory DefaultsSecond Keypad Options Third Keypad OptionsProgramming Descriptions Keypad Function Key Programming002 Zone Definitions System Times Installer CodeMaster Code O Programming Zones/PGMsFirst System Options Second System OptionsThird System Options Fourth System Options Tenth System OptionsOFF Keypad Always Active. The keypad does not blank 134 Zone Attributes Zone Loop Response OptionsDaylight Saving Time Move Clock Ahead Standard Time Set Clock BackCross Zone/Police Code Timer PGM Output TimerNo Activity Arm Timer Call Waiting Cancel StringCommunicator Variables Test Transmission TimeFirst Communicator Options Second Communicator Options OFF Closing Confirmation Disabled. The keypad does not beepThird Communicator Options First Downloading OptionsDownloading Computer Phone Number Downloading Access CodePanel Identification Code Number of Rings to Answer OnAutomatic Clock Adjust Way Audio Control Options applies to SCW9047 onlyFollowing attributes are available for PGM Output Type Wireless Programming Delay Between Dialing AttemptsFirst International Options Second International OptionsInstaller Lockout Enable Wireless Module Placement TestInstaller Lockout Disable Restore Wireless Device Default ProgrammingAlarm when Armed Event Message Fire Alarm Labels069 Command Output Label Keypad ProgrammingFirst Keypad Options OFF Power LED is disabled. Option 6 has no effectSecond Keypad Options Option Description Future UseThird Keypad Options Label ResetProgrammed LCD Message Programmed LCD Message DurationTesting & Troubleshooting Trouble 8 Loss of Clock/Date Trouble 4 Failure to CommunicateContact ID Appendix a Reporting Code FormatsSIA Format Automatic Zone Alarm/Restoral Codes Contact ID Zone Alarm/Restoral Event CodesAppendix B Communicator Format Options Residential Dial PagerNorth America Appendix C Regulatory Approvals InformationSIA False Alarm Reduction Installations EuropeNew Zealand Exit Time Appendix D SIA False Alarm ReductionFormat Reporting Code/Event Appendix E 2-Way Audio Verification SCW9047 onlyVOX Support Key Command DescriptionHang-up Auto-detection Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement