1.2 Wiring
1.2 Wiring
1. Zone Wiring
Zones can be wired for Normally Open, Normally Closed Contacts with Single-
•For UL/ULC listed installations use SEOL or DEOL only.
•Minimum 22 AWG wire, maximum 18 AWG
•Do NOT use shielded wire
•Wire run resistance shall not exceed 100Ω. Refer to the chart below.
| Burglary Zone Wiring Chart |
Wire | Max wire Length to |
Gauge | (feet/meters) |
|
|
22 | 3000 / 914 |
|
|
20 | 4900 / 1493 |
|
|
19 | 6200 / 1889 |
|
|
18 | 7800 / 2377 |
|
|
Figures are based on maximum wiring resistance of 100Ω
•Section [009] Selects Hardwired Zone Definition
•Sections [133], [134] Opt [14] selects Normally Closed
•Sections [133], [134] Opt [15] selects SEOL resistors
•Sections [133], [134] Opt [16] selects DEOL resistors.
Zone Status - Loop Resistance/Loop Status
•Fault - 0Ω (shorted wire/loop)
•Secure - 5600Ω (contact closed)
•Tamper - infinite (broken wire, open)
•Violated - 11,200Ω (contact open)
Normally Closed Loops - Do NOT use for UL Installations
Single
Double
2. PGM/Aux Power Wiring
PGMs switch to ground when activated by control panel.
Connect the plus side of the device to be activated to the AUX+ Terminal. Con- nect the minus terminal to the PGM. Each PGM can provide 50mA output.
NOTE: The control panel can provide a maximum of 100mA of AUX current for PGMs, relays, LED’s etc. Min/Max operating voltages for PGMs, relays and modules is 10.2VDC - 13.75VDC
NOTE: Battery Voltage
LED output with
I/O | I/O | current limiting |
resistor and optional Relay driver output
3. Telephone Line Wiring
Wire the telephone connection terminals (TIP, Ring,
For connection of multiple devices to the telephone line, wire in the sequence indicated.
Communication format is programmed in section [350]. Telephone Call Directions are programmed in section
TIP
RING
BRN |
|
GRA |
|
GRN |
|
RED | |
|
Note: For UL Listed Installations,the Installer must verify the communication format with the supervising station at the time of the installation.
4. Battery | 5. AC Wiring |
A 1500 mAHr
NOTE: UL/ULC Residential Burglary installations require 4 Hr. power standby time plus 4 minutes alarm annunciation.
NOTE: UL/ULC Residential Fire installations require 24 Hr. power standby plus 5 minutes alarm annunciation
NOTE: Battery life is
AC Transformer Requirements:
Primary:120VAC, 50/60Hz., 0.33A
240VAC, 50/60Hz., 0.165A Secondary: 16.5VAC/20VA
The following Transformers shall be used:
UL Listed Installations - PTD1620U, PTD1640U (60Hz.) ULC Listed installations - PTD1620, PTD1640 (60Hz.) EU Installations -
WWW.DIYALARMFORUM.COM3