Self Contained Wireless Alarm System v1.0
The following attributes are available for PGM Output Type [09]
[1]ON: PGM output activates if a Service Required trouble condition is present.
[2]ON: PGM output activates if an AC trouble condition is present.
[3]ON: PGM output activates if a Telephone Line trouble condition is present.
[4]ON: PGM output activates if a Failure to Communicate trouble condition is present.
[5]ON: PGM output activates if a Zone Fault condition is present.
[6]ON: PGM output activates if a Zone Tamper condition is present.
[7]ON: PGM output will activates if a Wireless Low Battery trouble condition is present.
[8]ON: PGM output will activates if a Loss of Clock trouble condition is present.
The following attributes are available for PGM Output Type [10]
[1]ON: PGM output activates if a Burglary Alarm occurs.
[2]ON: PGM output activates if a Fire Alarm occurs.
[3]ON: PGM output activates if a Panic Alarm occurs.
[4]ON: PGM output activates if a Medical Alarm occurs.
[5]ON: PGM output activates if a Supervisory Alarm occurs.
[6]ON: PGM output activates if a Priority Alarm occurs.
[7]ON: PGM output will activates if a
[8]ON: the PGM output activates for the time programmed for the PGM Output Timer.
OFF: the PGM output will latch until a valid user code is entered.
Section [600] 2-way Audio Control Options (applies to SCW9047 only)
Option Description
[1]ON: Tampers Enabled. The
OFF: Tampers Disabled.
[2]ON: Openings and Closings Enabled. The
OFF: Openings and Closings Disabled.
[3]ON: [A] Key Alarm Enabled. The
OFF: [A] Key Alarm Disabled.
[4]ON: [P] Key Alarm Enabled. The
OFF: [P] Key Alarm Disabled.
[5]ON: Duress Alarm Enabled (Listen). The
OFF: Duress Alarm Disabled.
[6]ON: Opening after Alarm Enabled. The
OFF: Opening after Alarm Disabled.
[7]ON: Bell Active during
alarm is present OFF: Bell Silent during
This option must be ON for UL Listed Installations.
[8]Future Use
Section [700] Automatic Clock Adjust
Program the number of seconds for the last minute of the day. This can be used to make minor corrections to the clock if the AC frequency is not reliable. Valid entries are [01] to [99].
42WWW.DIYALARMFORUM.COM