DSCover Satellite Products SCW904x manual Wireless Module Placement Test, Installer Lockout Enable

Page 48

Self Contained Wireless Alarm System v1.0

Sub Section [82]-[85] Wireless Zone Supervision (Zones 1 - 32)

Programming these sections determines whether or not the zone transmitter will be supervised.

Panic Pendants do not send Supervisory signals and cannot be supervised.

Sub Section [90] General Wireless Options (Zones 1 - 32)

Option Description

[1]-[6] Future Use

[7]ON: RF Jam Disabled.RF Jam is disabled. OFF: RF Jam Enabled. RF Jam is enabled.

[8]ON: Global Placement Test All placements (zones) tested. OFF: Individual Module Placement Test. Installer must enter zone number for placement test.

Section [898]: Wireless Device Enrollment - See Section 2 of this manual.

Section [899]: Template Programming - See Section 3 of this manual.

Section [900]: Panel Version Displayed

Section [900]: Display Panel Version. The system will display the version of the control panel (for example, [0100] indicates panel version 1.00).

Section [904]: Wireless Module Placement Test

Enter Section [904] followed by the 2-digit number of the wireless zone to test. When a wireless signal is received from the selected transmitter, the system will indicate the location as Good or Bad as follows:

Good: One bell squawk, keypad displays ‘GOOD’

Bad: Three bell squawks, keypad displays ‘BAD’

Press [#] to exit when testing is complete. Enter the 2-digit zone number for the next wireless device to test or press [#] to return to standard pro- gramming.

Section [990] Installer Lockout Enable

Enter Section [990][Installer Code][990] to enable the Installer Lockout feature. A hardware default cannot be performed when the Installer Lockout feature is ON. In addition, the system will chatter the line seizure relay 10 times if the panel is powered up to indicate the feature is ON.

Section [991] Installer Lockout Disable

Enter Section [991][Installer Code][991] to turn the Installer Lockout feature OFF.

Section [996] Restore Wireless Device Default Programming

Enter Section [996][Installer Code][996] to return wireless programming to factory defaults.

Section [998] Restore Control Panel Default Programming

Enter Section [998][Installer Code][998] to return control panel programming to factory defaults.

Wireless device programming and keypad programming are not defaulted

To default Labels see Section [996] Label Reset in Keypad Programming

To default Wireless Devices see Section [996] above

Section [999] Restore System Default Programming

Enter Section [999][Installer Code][999] to return system programming to factory defaults.

Except for Labels, All programming including wireless device programming and keypad programming will be returned to factory defaults. To default Labels see Section [996] Label Reset in Keypad Programming

Hardware Reset (Default) Main Control Panel

Perform the following to default the main control panel:

Power down the system completely.

Connect a short between I/O 1 and I/O 2 on the control panel (remove all other wires from these terminals).

Power up the control panel (AC power only) for 10 full seconds.

Power down the control panel, remove short between I/O 1 and I/O 2.

Power up the control panel.

44WWW.DIYALARMFORUM.COM

Image 48
Contents Installation Guide Before Installing The Equipment Selecting a Suitable Location For The Alarm ControllerSafety Precautions required during Installation Table of Contents Page Installation & Wiring Technical SummaryInstallation Ensure connector key is oriented correctlyWiring Burglary Zone Wiring ChartMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Wireless Device Enrollment Enter Wireless Enrollment ModeActivate Wireless Device Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Template Programming Zone Definitions Options 1Digit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out New Installations Refer to .1 Installation on Existing Installations Refer to .1 Installation onDLS Programming Local Programming with PC-LinkOperation Alarm Memory Display Door Chime Enable/DisableTrouble Display Program User Codes7x Command Outputs 1&2 Installer ProgrammingAdditional Keypad Functions 9User Code No-Entry ArmingAdvanced Programming Programming Work Sheets Index to Programming Work Sheets and DescriptionsProgramming Worksheets Function Key ProgrammingFunction Key Options Zone DefinitionsInstaller’s Code Master Code System Times009 I/O Programming Keypad Lockout OptionsSecond System Options Third System OptionsFourth System Options Tenth System OptionsZone Loop Response Options Zone Attributes Options 10-13 are reserved for Future UsePGM Output Timer Cross Zone/Police Code TimerNo Activity Arming Pre-alert Timer No Activity Arming TimerAlarm Reporting Codes, Zones Alarm Restoral Reporting Codes, ZonesMiscellaneous Alarm Reporting Codes Priority Alarm and Restoral Reporting CodesTamper Reporting Codes, Zones Tamper Restoral Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Tamper/Restore Communicator Call Directions Communicator Format OptionsOpening/Closing Communicator Call Directions System Maintenance Communicator Call Directions System Test Transmissions Communicator Call DirectionsCommunication Variables Test Transmission Time of DaySecond Communicator Options Third Communicator OptionsDownloading Options Number of Rings To Answer On Initiate PC-Link DownloadingPGM Output Attributes AttributeAutomatic Clock Adjust Delay Between Dialing Attempts600 2-way Audio Control Options Applies to SCW9047 only First International OptionsWireless programming Wireless Zone Programming Wireless Supervisory WindowGeneral Wireless Options Wireless Module Placement Test Installer Lockout EnableInstaller Lockout Disable Restore Wireless Device Default ProgrammingLocal Keypad Programming Label Programming ZoneFire Alarm Label Alarm When Armed Event MessageCommand Output #1 Label Command Output #2 LabelReset Programmable Labels to Factory Defaults First Keypad OptionsSecond Keypad Options Third Keypad OptionsProgramming Descriptions Keypad Function Key Programming002 Zone Definitions Installer Code System TimesMaster Code O Programming Zones/PGMsFirst System Options Second System OptionsThird System Options Fourth System Options Tenth System OptionsOFF Keypad Always Active. The keypad does not blank Zone Loop Response Options 134 Zone AttributesDaylight Saving Time Move Clock Ahead Standard Time Set Clock BackPGM Output Timer Cross Zone/Police Code TimerNo Activity Arm Timer Call Waiting Cancel StringCommunicator Variables Test Transmission TimeFirst Communicator Options OFF Closing Confirmation Disabled. The keypad does not beep Second Communicator OptionsThird Communicator Options First Downloading OptionsDownloading Access Code Downloading Computer Phone NumberPanel Identification Code Number of Rings to Answer OnAutomatic Clock Adjust Way Audio Control Options applies to SCW9047 onlyFollowing attributes are available for PGM Output Type Delay Between Dialing Attempts Wireless ProgrammingFirst International Options Second International OptionsWireless Module Placement Test Installer Lockout EnableInstaller Lockout Disable Restore Wireless Device Default ProgrammingFire Alarm Labels Alarm when Armed Event Message069 Command Output Label Keypad ProgrammingOFF Power LED is disabled. Option 6 has no effect First Keypad OptionsSecond Keypad Options Option Description Future UseLabel Reset Third Keypad OptionsProgrammed LCD Message Programmed LCD Message DurationTesting & Troubleshooting Trouble 4 Failure to Communicate Trouble 8 Loss of Clock/DateAppendix a Reporting Code Formats Contact IDContact ID Zone Alarm/Restoral Event Codes SIA Format Automatic Zone Alarm/Restoral CodesAppendix B Communicator Format Options Pager Residential DialAppendix C Regulatory Approvals Information North AmericaSIA False Alarm Reduction Installations EuropeNew Zealand Appendix D SIA False Alarm Reduction Exit TimeAppendix E 2-Way Audio Verification SCW9047 only Format Reporting Code/EventKey Command Description VOX SupportHang-up Auto-detection Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement