Section [074] First Keypad Options

Option Description

[1]Future Use

[2]ON: [A] Key Enabled. When the [A] key is pressed and held, the keypad will generate a [A]ux key alarm. The display will prompt the user to hold the key.

OFF: [A] Key Disabled. Prevents the keypad from requesting a [A]ux key alarm.

[3]ON: [P] Key Enabled. When the [P] key is pressed and held, the keypad will generate a [P]anic key alarm. The display will prompt

the user to hold the key, depending on the setting of Option 8 (in this section). OFF: [P] Key Disabled. Prevents the keypad from requesting a [P]anic key alarm.

[4]ON: Quick Arm Prompt is enabled. When in the Disarmed Star menu, the Quick Arm prompt will be displayed.

OFF: Quick Arm Prompt is disabled. The Quick Arm prompt is disabled.

[5]ON: Quick Exit Prompt is enabled. When in the Armed Star menu, the Quick Exit prompt will be displayed.

OFF: Quick Exit Prompt is disabled. The Quick Exit prompt is disabled.

[6]ON: Bypass Options Prompt is enabled. In the [*1] Bypass menu, the Bypass Options prompt will be displayed. This is a local

function prompt. When selected, the keypad will display the Bypass Options menu. OFF: Bypass Options Prompt and menu is disabled. Prompt and menu is disabled.

[7]ON: User Initiated Call-Up Prompt is enabled. In the [*6] User Functions menu, the User Initiated Call-up prompt will be Dis- played. When this prompt is selected, the keypad will send a [6] key.

OFF: User Initiated Call-Up Prompt is disabled. The prompt is not displayed.

[8]ON: Hold [P] Key Prompt is enabled. When holding the [P] key, the display will prompt the user to hold the [P] key to generate a

Panic alarm. This is a local prompt.OFF: Hold [P] Key Prompt is disabled. When holding the [P] key, the user will receive no feed- back that the key has been pressed. The display and backlighting will not change.

Section [075] Second Keypad Options

Option Description

[1]ON: Local Clock Enabled: When the keypad is not being used, the keypad will return to displaying the Time and Date until another

key is pressed. OFF: Local Clock Disabled

[2]ON: Local Clock Displays 24 Hour Time. When this feature is enabled, the time is displayed in 24 hour military format.

OFF: Local Clock Displays AM/PM Time. When this feature is enabled, the time is displayed in 12 hour format (AM/PM).

This option does not affect the time programming menu, which is always in 24-hour time format.

[3]ON: Auto Alarm Scroll Enabled. When the bell is active or when there is an alarm in memory while armed, the keypad will scroll automatically and display all alarms.

OFF: Auto Alarm Scroll Disabled. The keypad will not scroll automatically and display all alarms.

[4]ON: Language Selection Accessible from Any Menu. Pressing <> and holding for 2 seconds displays the language selection menu.

OFF: Language Selection Accessible from Installer’s Menu Only. Pressing <> and holding for 2 seconds generates an error tone.

[5]ON: Power LED is enabled. The LED functionality is defined by Option 6.

OFF: Power LED is disabled. Option 6 has no effect.

[6]ON: Power LED Indicates AC Present. If AC is present then the LED will be ON to indicate AC power is present. If AC is absent then the LED will be OFF indicating that the AC power is lost.

OFF: Power LED Indicates AC Absent. If AC is present then the LED will be OFF to indicate that the AC is present and there is no trouble. If the AC is absent then the LED will be ON steady to indicate that there is a problem with the AC power.

[7]ON: Alarms are Displayed while Armed. If any alarms occur while armed, the keypad will display the alarms by identifying the

zones.OFF: Alarms are Not Displayed while Armed. If any alarms occur while armed, the keypad will not show any indication that an alarm occurred on the system. When the system is disarmed, the keypad will still enter Alarm Memory to indicate which zones went into alarm during the alarm period.

[8]ON: Auto Scroll of Open Zones is enabled. When a zone is open, the keypad will scroll automatically and display all open zones.

Open zones also override the local clock display. OFF: Auto Scroll of Open Zones is disabled. Open zones are not displayed

46WWW.DIYALARMFORUM.COM

Image 50
Contents Installation Guide Safety Precautions required during Installation Before Installing The EquipmentSelecting a Suitable Location For The Alarm Controller Table of Contents Page Installation & Wiring Technical SummaryInstallation Ensure connector key is oriented correctlyMax wire Length to End-of-line Resistor WiringBurglary Zone Wiring Chart Self Contained Wireless Alarm System Activate Wireless Device Wireless Device EnrollmentEnter Wireless Enrollment Mode Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Template Programming Zone Definitions Options 1Digit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out DLS Programming New Installations Refer to .1 Installation onExisting Installations Refer to .1 Installation on Local Programming with PC-LinkOperation Trouble Display Alarm Memory DisplayDoor Chime Enable/Disable Program User CodesAdditional Keypad Functions 7x Command Outputs 1&2Installer Programming 9User Code No-Entry ArmingAdvanced Programming Programming Work Sheets Index to Programming Work Sheets and DescriptionsFunction Key Options Programming WorksheetsFunction Key Programming Zone Definitions009 I/O Programming Installer’s Code Master CodeSystem Times Keypad Lockout OptionsFourth System Options Second System OptionsThird System Options Tenth System OptionsZone Loop Response Options Zone Attributes Options 10-13 are reserved for Future UseNo Activity Arming Pre-alert Timer PGM Output TimerCross Zone/Police Code Timer No Activity Arming TimerMiscellaneous Alarm Reporting Codes Alarm Reporting Codes, ZonesAlarm Restoral Reporting Codes, Zones Priority Alarm and Restoral Reporting CodesMiscellaneous Opening Disarming Reporting Codes Tamper Reporting Codes, ZonesTamper Restoral Reporting Codes, Zones Opening/Closing Communicator Call Directions Tamper/Restore Communicator Call DirectionsCommunicator Format Options Communication Variables System Maintenance Communicator Call DirectionsSystem Test Transmissions Communicator Call Directions Test Transmission Time of DayDownloading Options Second Communicator OptionsThird Communicator Options PGM Output Attributes Number of Rings To Answer OnInitiate PC-Link Downloading Attribute600 2-way Audio Control Options Applies to SCW9047 only Automatic Clock AdjustDelay Between Dialing Attempts First International OptionsWireless programming Wireless Zone Programming Wireless Supervisory WindowInstaller Lockout Disable General Wireless OptionsWireless Module Placement Test Installer Lockout Enable Restore Wireless Device Default ProgrammingLocal Keypad Programming Label Programming ZoneCommand Output #1 Label Fire Alarm LabelAlarm When Armed Event Message Command Output #2 LabelSecond Keypad Options Reset Programmable Labels to Factory DefaultsFirst Keypad Options Third Keypad Options002 Zone Definitions Programming DescriptionsKeypad Function Key Programming Master Code Installer CodeSystem Times O Programming Zones/PGMsThird System Options First System OptionsSecond System Options OFF Keypad Always Active. The keypad does not blank Fourth System OptionsTenth System Options Daylight Saving Time Move Clock Ahead Zone Loop Response Options134 Zone Attributes Standard Time Set Clock BackNo Activity Arm Timer PGM Output TimerCross Zone/Police Code Timer Call Waiting Cancel StringFirst Communicator Options Communicator VariablesTest Transmission Time Third Communicator Options OFF Closing Confirmation Disabled. The keypad does not beepSecond Communicator Options First Downloading OptionsPanel Identification Code Downloading Access CodeDownloading Computer Phone Number Number of Rings to Answer OnFollowing attributes are available for PGM Output Type Automatic Clock AdjustWay Audio Control Options applies to SCW9047 only First International Options Delay Between Dialing AttemptsWireless Programming Second International OptionsInstaller Lockout Disable Wireless Module Placement TestInstaller Lockout Enable Restore Wireless Device Default Programming069 Command Output Label Fire Alarm LabelsAlarm when Armed Event Message Keypad ProgrammingSecond Keypad Options OFF Power LED is disabled. Option 6 has no effectFirst Keypad Options Option Description Future UseProgrammed LCD Message Label ResetThird Keypad Options Programmed LCD Message DurationTesting & Troubleshooting Trouble 4 Failure to Communicate Trouble 8 Loss of Clock/DateAppendix a Reporting Code Formats Contact IDContact ID Zone Alarm/Restoral Event Codes SIA Format Automatic Zone Alarm/Restoral CodesAppendix B Communicator Format Options Pager Residential DialAppendix C Regulatory Approvals Information North AmericaNew Zealand SIA False Alarm Reduction InstallationsEurope Appendix D SIA False Alarm Reduction Exit TimeAppendix E 2-Way Audio Verification SCW9047 only Format Reporting Code/EventHang-up Auto-detection Key Command DescriptionVOX Support Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement