Self Contained Wireless Alarm System v1.0
4.Initiating, Control and Termination of the Session: The Operator controls the session the using the following Audio Control Telephone Key Functions.To select the following commands, Press [*][0] followed by the key number(s) indicated below
Key | Command | Description |
|
|
|
0 | Future Use |
|
|
|
|
1/4 | Talk to Speaker | Connects the monitoring station to the speaker . |
|
|
|
2 | VOX Mode | Connects the monitoring station to the system in VOX Mode (See VOX Sup- |
|
| port below) |
|
|
|
3/6 | Listen to Microphone | Connects the monitoring station to the microphone. |
|
|
|
4 | Connects the monitoring station to the speaker at the low volume output | |
|
| level. |
|
|
|
5 | Future Use |
|
|
|
|
6 | Connects the monitoring station to the microphone at the low gain input | |
| phone | level. |
|
|
|
7 | Extend Time | Restarts the session timer (90 seconds) to prevent timeout. To extend the |
|
| time and take no other action use this function. Pressing any key |
|
| automatically extends the time. |
|
|
|
88 | Future Use |
|
|
|
|
99 | Disconnect | Disconnects the session. The second ‘9’ must be pressed within 1 second of |
|
| pressing the first ‘9’. Use the “Disconnect” key sequence before hang- |
|
| ing up during a Talk / |
|
|
|
VOX Support
When in VOX mode the SCW9047 automatically switch between the phone line and internal mic/speakers being active depending on which one is loudest. Push to Talk overrides VOX – this is performed by switching into a talk mode at the monitoring station .
Hang-up Auto-detection
The SCW9047 automatically disconnects if the central station receiver disconnects before the operator picks up the line. The SCW9047 will consider five seconds of continuous dial tone, or busy tone to be a disconnect condition.
Bell/Buzzer Silent During 2-Way Audio
When the panel has an audible alarm, the bell can be programmed to remain active until the