DSCover Satellite Products SCW904x Trouble Display, Alarm Memory Display, Program User Codes

Page 16

Self Contained Wireless Alarm System v1.0

[ ][2] – Trouble Display

Refer to Appendix E: Troubleshooting Guide, for troubleshooting assistance and a detailed description of all trouble conditions.

[ ][3] – Alarm Memory Display

Pressing the scroll <> keys will display an “Alarms in Memory” message if an alarm occurred during the last armed period. Pressing [ ][3] will display the message “Scroll to view Alarms”. Scrolling will display the zones that went into alarm. To clear the Memory, arm then disarm the system.

[ ][4] – Door Chime Enable/Disable

Press [ ][4]. The keypad will emit 3 rapid beeps to indicate that the door chime feature is now enabled and a steady 2-second tone if it is now dis- abled. The same function can be performed by pressing and holding the Chime function button for 2 seconds.

[ ][5] – Program User Codes

The following table identifies available user codes:

Code

Type

Function

 

 

 

[01] – [16]

General User Codes

Arm, disarm, attribute functions

[40]

Master Code

All functions, arm, disarm, program user codes

 

 

 

Programming User Codes:

Press [ ][5] followed by the Master Code. The keypad will display the first user (user 01) and include the letter ‘P’ if the user code is pro- grammed. Scroll to the appropriate user and press the [ ] key to program the user (or enter the 2-digit user number). Enter a new 4 or 6-digit user code or press [ ] to delete the user code. After the user code is programmed or deleted, scroll to another user or press [#] to exit.

Programming User Attributes:

Press [ ][5] followed by the Master Code or Supervisor Code. Press [9] followed by the 2-digit user to change to the user attributes.

[1]Supervisor’s Code

This attribute makes the code valid when entering the [ ][5] User Code Programming section and [ ][6] User Functions. Note, these codes can only program codes which have equal or lesser attributes. This attribute will also allow this user to create bypass groups if an access code is required to enter into [ ][1] Bypassing.

[2]Duress Code

Duress codes are standard user codes that will transmit the Duress Reporting Code whenever the code is entered to perform any function on the system.

[3]User can manually bypass zones if Bypassing requires an access code.

[4]-[6]

Future Use

[7]The panel will squawk the bell output when the user arms or disarms when in Away Armed mode.

[8]One-time Use Code

The One-time-use Code allows unlimited arming but only permits a single disarming once a day. The Disarm function is restored at midnight.

To change the user attributes, press the number corresponding to the attribute or scroll to the desired attribute and press [ ]. When the correct attributes are assigned to the user, press [#] to exit. To change the user attributes for another user, press [9] followed by the 2-digit user number. When finished, press [#] to exit.

These attributes affect the operation of wireless keys

Duress codes are not valid when entering [*][5], [*][6] or [*][8] sections and will transmit a duress alarm. Duplicate codes and codes that are +/- 1 of an existing code can not be programmed.

[ ][6] – User Functions

Press [

][6] followed by the Master Code, then press the number corresponding to the following functions or scroll to the desired option, then

press [

].

[1]Program Time and Date: Enter the time and date using the following format [HH:MM] [MM/DD/YY]. Program the time using military standard (e.g., 8:00 pm = 20:00 hours).

[2]-[3] Future Use

12WWW.DIYALARMFORUM.COM

Image 16
Contents Installation Guide Selecting a Suitable Location For The Alarm Controller Before Installing The EquipmentSafety Precautions required during Installation Table of Contents Page Installation & Wiring Technical SummaryInstallation Ensure connector key is oriented correctlyBurglary Zone Wiring Chart WiringMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Wireless Device Enrollment Enter Wireless Enrollment ModeActivate Wireless Device Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Template Programming Zone Definitions Options 1Digit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out New Installations Refer to .1 Installation on Existing Installations Refer to .1 Installation onDLS Programming Local Programming with PC-LinkOperation Alarm Memory Display Door Chime Enable/DisableTrouble Display Program User Codes7x Command Outputs 1&2 Installer ProgrammingAdditional Keypad Functions 9User Code No-Entry ArmingAdvanced Programming Programming Work Sheets Index to Programming Work Sheets and DescriptionsProgramming Worksheets Function Key ProgrammingFunction Key Options Zone DefinitionsInstaller’s Code Master Code System Times009 I/O Programming Keypad Lockout OptionsSecond System Options Third System OptionsFourth System Options Tenth System OptionsZone Loop Response Options Zone Attributes Options 10-13 are reserved for Future UsePGM Output Timer Cross Zone/Police Code TimerNo Activity Arming Pre-alert Timer No Activity Arming TimerAlarm Reporting Codes, Zones Alarm Restoral Reporting Codes, ZonesMiscellaneous Alarm Reporting Codes Priority Alarm and Restoral Reporting CodesTamper Restoral Reporting Codes, Zones Tamper Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Communicator Format Options Tamper/Restore Communicator Call DirectionsOpening/Closing Communicator Call Directions System Maintenance Communicator Call Directions System Test Transmissions Communicator Call DirectionsCommunication Variables Test Transmission Time of DayThird Communicator Options Second Communicator OptionsDownloading Options Number of Rings To Answer On Initiate PC-Link DownloadingPGM Output Attributes AttributeAutomatic Clock Adjust Delay Between Dialing Attempts600 2-way Audio Control Options Applies to SCW9047 only First International OptionsWireless programming Wireless Zone Programming Wireless Supervisory WindowGeneral Wireless Options Wireless Module Placement Test Installer Lockout EnableInstaller Lockout Disable Restore Wireless Device Default ProgrammingLocal Keypad Programming Label Programming ZoneFire Alarm Label Alarm When Armed Event MessageCommand Output #1 Label Command Output #2 LabelReset Programmable Labels to Factory Defaults First Keypad OptionsSecond Keypad Options Third Keypad OptionsKeypad Function Key Programming Programming Descriptions002 Zone Definitions Installer Code System TimesMaster Code O Programming Zones/PGMsSecond System Options First System OptionsThird System Options Tenth System Options Fourth System OptionsOFF Keypad Always Active. The keypad does not blank Zone Loop Response Options 134 Zone AttributesDaylight Saving Time Move Clock Ahead Standard Time Set Clock BackPGM Output Timer Cross Zone/Police Code TimerNo Activity Arm Timer Call Waiting Cancel StringTest Transmission Time Communicator VariablesFirst Communicator Options OFF Closing Confirmation Disabled. The keypad does not beep Second Communicator OptionsThird Communicator Options First Downloading OptionsDownloading Access Code Downloading Computer Phone NumberPanel Identification Code Number of Rings to Answer OnWay Audio Control Options applies to SCW9047 only Automatic Clock AdjustFollowing attributes are available for PGM Output Type Delay Between Dialing Attempts Wireless ProgrammingFirst International Options Second International OptionsWireless Module Placement Test Installer Lockout EnableInstaller Lockout Disable Restore Wireless Device Default ProgrammingFire Alarm Labels Alarm when Armed Event Message069 Command Output Label Keypad ProgrammingOFF Power LED is disabled. Option 6 has no effect First Keypad OptionsSecond Keypad Options Option Description Future UseLabel Reset Third Keypad OptionsProgrammed LCD Message Programmed LCD Message DurationTesting & Troubleshooting Trouble 4 Failure to Communicate Trouble 8 Loss of Clock/DateAppendix a Reporting Code Formats Contact IDContact ID Zone Alarm/Restoral Event Codes SIA Format Automatic Zone Alarm/Restoral CodesAppendix B Communicator Format Options Pager Residential DialAppendix C Regulatory Approvals Information North AmericaEurope SIA False Alarm Reduction InstallationsNew Zealand Appendix D SIA False Alarm Reduction Exit TimeAppendix E 2-Way Audio Verification SCW9047 only Format Reporting Code/EventKey Command Description VOX SupportHang-up Auto-detection Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement