Self Contained Wireless Alarm System v1.0
Appendix D: SIA False Alarm Reduction
SIA Feature | Comments | Range/Default | Require- |
Programming Section |
|
| ment |
|
|
|
|
Exit Time | Access to Entry and Exit delays and Bell Time Out for the system | Range:45- 255 seconds | Required |
[005], 3rd entry |
| Default: 60 sec. | (programmable) |
|
|
|
|
Progress Annunciation/ | Enables audible exit beeps from the keypad for the duration of exit delay | Keypads may be disabled | Allowed |
Disable - for Silent Exit |
| Default: Enabled |
|
[014], Option 6 ON |
|
|
|
|
|
|
|
Exit Time Restart | Enables the exit delay restart feature | Default: Enabled | Required |
[014], Option 2 ON |
|
|
|
|
|
|
|
Auto Stay Arm on | Function Key: Stay Arming. All Stay/Away type zones (05, 06) will be automatically | If no exit after full arm | Required |
Unvacated Premises | bypassed | Default: Enabled |
|
|
|
| |
|
|
|
|
Exit Time and Progress | System Times and Audible Exit beeps can be disabled when using the Key fob to arm | Default: Enabled | Allowed |
Annunciation/Disable | away the system |
|
|
or Remote Arming |
|
|
|
[005] and [014] bit 6 |
|
|
|
|
|
|
|
Entry delay(s) | Access to Entry and Exit delays and Bell Time Out for the system | Range: 30 sec. to 4 min. | Required |
[005], 1st and 2nd entry | Note: Combined Entry delay and Communications Delay (Abort Window) shall not | Default: 30 sees | (programmable) |
| exceed 60s |
|
|
|
|
|
|
Abort Window | Access to zone attributes, i.e, swinger shutdown, transmission delay and cross zone. | May be disabled | Required |
for | Individual zones attribute bit 6 (Transmission delay) is by default ON | by zone or zone type |
|
| Default: Enabled |
| |
|
|
|
|
Abort Window - for | Access to the programmable delay before communicating alarms | Range: 15 - 45 sec. | Required |
Note: Combined Entry delay and Communications Delay (Abort Window) shall not | Default: 30 sees | (programmable) | |
[377], 4th entry | exceed 60s |
|
|
|
|
|
|
Abort Annunciation | Enables the “Communication Cancelled” message display on keypad | Annunciate that no | Required |
[382], Option 3 ON |
| alarm was transmitted |
|
|
| Default: Enabled |
|
|
|
|
|
Cancel Annunciation | Access to the reporting code for Alarm Cancelled | Annunciate that a | Required |
[328], 8th entry |
| Cancel was transmitted |
|
|
| Default: Enabled |
|
|
|
|
|
Duress Feature | Do not derive code from an existing Master/User code (e.g., Master code is 1234, the | No 1+/- derivative of another | Allowed |
[*][5] Master Code | duress code should not be 1233 or 1235) | user code. No duplicates with |
|
Option 2 ON |
| other user codes |
|
|
| Default: disabled |
|
|
|
|
|
Cross Zoning | This option enables Cross Zoning for entire system. Individual zones can be enabled | Programming required | Required |
[016] Option 1 | for Cross zoning via Zone attribute bit 8 in sections [101] - [134] | Default: Disabled |
|
|
|
| |
|
|
|
|
Cross Zone Timer | Access to the programmable Cross Zone timer | May program | Allowed |
[176] |
| Range: |
|
|
| Default: 60 secs |
|
|
|
|
|
Swinger Shutdown for Alarms | Access to the swinger shutdown limit for zone alarms | For all | Required |
[377] 1st entry |
| shut down at 1 or 2 trips | (programmable) |
|
| Default: 1 Trip |
|
|
|
|
|
Swinger Shutdown Enable | Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone. | For | Allowed |
[101] - [134] bit 6 ON | Individual zones attribute bit 6 (Swinger shutdown enabled) is by default ON | response zones |
|
|
| Default: Enabled |
|
|
|
|
|
Access to | Activates If a restoral is Not | Required | |
(Wireless) Zone type [89] |
| received within the specified |
|
|
| time |
|
|
| Default: disabled |
|
|
|
|
|
Call Waiting Cancel Dial String | Access to the dialing sequence used to disable call waiting | Dependant on user phone | Required |
[304], [382], Option 4 OFF |
| line |
|
|
| Default: disabled |
|
|
|
|
|
| Testing |
|
|
|
|
|
|
System Test: | The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on. |
| |
[*][6] Master Code, Option 4 | Refer to the User Manual (part no. 29007326). |
|
|
|
|
|
|
Walk Test Mode: | This mode is used to test each zone on the system for proper functionality. |
|
|
[*][6] Opt 8 |
|
|
|
|
|
|
|
Alarm Communications | Enables Communication of zone alarms while Walk Test is active. |
|
|
During Walk Test |
|
|
|
[382] Option 2: |
|
|
|
|
|
|
|
Walk Test End and Begin | Access to the reporting codes for Walk Test Begin and Walk Test End. |
|
|
Reporting Codes |
|
|
|
[348], 1st and 2nd Entries |
|
|
|