DSCover Satellite Products SCW904x manual Template Programming, Zone Definitions Options 1

Page 11

Section 3: Template Programming

Section 3: Template Programming

Template programming allows the Installer to quickly program the minimum functions required for basic operation. The installer is prompted to enter a 4-digit code that selects predefined zone definitions, reporting code formats, Troubles & Restorals, and DLS setup (see Digit 1 - 4 tables below). The Installer is then prompted to enter the Central Station Telephone Number & Account Code, DLS Access Code, Entry & Exit Delays and Installer Code (see entry 5-9 below).

Selecting [ ][8] [Installer Code] [899] displays the default settings for the first 4 options below.

Once this section has been entered, the Installer cannot exit until all sections are completed. Enter new data and/or Press # key to accept the displayed data and proceed to the next section.

Changing a single digit, then pressing the # key will advance to the next section but will not save the changed data. Enter all 4 digits or scroll to the end of template programming and exit to save data.

Digit 1 selects 1 of the following 6 options for Zone definitions for the first 8 zones. A ‘0’ in the digit 1 location

indicates that the default settings for the first 8 zones are in place unless overridden. See Section [001]-[002] on page 16 for defaults.

Option

Zn1

Zn2

Zn3

Zn4

Zn5

Zn6

Zn7

Zn8

 

 

 

 

 

 

 

 

 

1

1

3

3

3

4

4

4

4

 

 

 

 

 

 

 

 

 

2

1

3

3

5

5

5

5

88

 

 

 

 

 

 

 

 

 

3

1

3

3

5

5

5

5

87

 

 

 

 

 

 

 

 

 

4

1

1

3

3

3

3

3

3

 

 

 

 

 

 

 

 

 

5

1

3

3

6

5

5

5

5

 

 

 

 

 

 

 

 

 

6

1

3

3

6

5

5

5

88

 

 

 

 

 

 

 

 

 

Refer to Section 8 for zone definition details

Zone Definitions (Options 1- 6)

1 Delay 1

2 Delay 2

3Instant

4Interior

5Interior Stay/Away

6Delayed Stay/Away

87 Delayed 24Hr. Fire (Wireless)

88 Standard 24 Hr. Fire (Wireless)

Digit 2 selects 1 of the following 6 options for Reporting Codes

Opt#

Phone Line 1

Programming Section

Phone Line 2

Programming Section

 

 

 

 

 

 

1

Disabled

[380] Opt 1 OFF

Disabled

 

 

 

 

 

 

 

 

2

SIA automatic Reporting Codes enabled

[350] 1st Phone # [04]

SIA Automatic Reporting Codes

[350]

2nd Phone # [04]

 

 

[380]

Opt 1 ON

Enabled

 

 

 

 

[381]

Opt 3 OFF

 

 

 

 

 

 

 

 

 

3

Contact ID Reporting Codes enabled

[350] 1st Phone # [03]

SIA Automatic Reporting Codes

[350]

2nd Phone # [04]

 

 

[380]

Opt 1 ON

Enabled

[381]

Opt [03] OFF

 

 

[381]

Opt 7 OFF

 

 

 

 

 

 

 

 

 

4

SIA automatic Reporting Codes enabled

[350] 1st Phone #[04]

Residential Dial

[350]

2nd Phone # [06]

 

 

[380]

Opt 1 ON

Enabled

 

 

 

 

[381]

Opt 3 OFF

 

 

 

 

 

 

 

 

 

5

Contact ID Reporting Codes enabled

[350] 1st Phone # [03]

Residential Dial

[350]

2nd Phone # [06]

 

 

[380]

Opt 1

ON

Enabled

 

 

 

 

[381]

Opt 7

OFF

 

 

 

 

 

 

 

 

 

6

Contact ID Reporting Codes enabled

[350] 1st Phone # [03]

Contact ID Reporting Codes

[350]

2nd Phone # [03]

 

 

[380]

Opt 1

ON

Enabled

 

 

 

 

[381]

Opt 7

OFF

 

 

 

 

 

 

 

 

 

 

 

WWW.DIYALARMFORUM.COM7

Image 11
Contents Installation Guide Safety Precautions required during Installation Before Installing The EquipmentSelecting a Suitable Location For The Alarm Controller Table of Contents Page Technical Summary Installation & WiringEnsure connector key is oriented correctly InstallationMax wire Length to End-of-line Resistor WiringBurglary Zone Wiring Chart Self Contained Wireless Alarm System Verify Device Electronic Serial Number ESN Wireless Device EnrollmentEnter Wireless Enrollment Mode Activate Wireless DeviceZone Dependant Devices Detectors Zone Definitions Options 1 Template ProgrammingDigit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out Local Programming with PC-Link New Installations Refer to .1 Installation onExisting Installations Refer to .1 Installation on DLS ProgrammingOperation Program User Codes Alarm Memory DisplayDoor Chime Enable/Disable Trouble Display9User Code No-Entry Arming 7x Command Outputs 1&2Installer Programming Additional Keypad FunctionsAdvanced Programming Index to Programming Work Sheets and Descriptions Programming Work SheetsZone Definitions Programming WorksheetsFunction Key Programming Function Key OptionsKeypad Lockout Options Installer’s Code Master CodeSystem Times 009 I/O ProgrammingTenth System Options Second System OptionsThird System Options Fourth System OptionsZone Attributes Options 10-13 are reserved for Future Use Zone Loop Response OptionsNo Activity Arming Timer PGM Output TimerCross Zone/Police Code Timer No Activity Arming Pre-alert TimerPriority Alarm and Restoral Reporting Codes Alarm Reporting Codes, ZonesAlarm Restoral Reporting Codes, Zones Miscellaneous Alarm Reporting CodesMiscellaneous Opening Disarming Reporting Codes Tamper Reporting Codes, ZonesTamper Restoral Reporting Codes, Zones Opening/Closing Communicator Call Directions Tamper/Restore Communicator Call DirectionsCommunicator Format Options Test Transmission Time of Day System Maintenance Communicator Call DirectionsSystem Test Transmissions Communicator Call Directions Communication VariablesDownloading Options Second Communicator OptionsThird Communicator Options Attribute Number of Rings To Answer OnInitiate PC-Link Downloading PGM Output AttributesFirst International Options Automatic Clock AdjustDelay Between Dialing Attempts 600 2-way Audio Control Options Applies to SCW9047 onlyWireless Supervisory Window Wireless programming Wireless Zone ProgrammingRestore Wireless Device Default Programming General Wireless OptionsWireless Module Placement Test Installer Lockout Enable Installer Lockout DisableLabel Programming Zone Local Keypad ProgrammingCommand Output #2 Label Fire Alarm LabelAlarm When Armed Event Message Command Output #1 LabelThird Keypad Options Reset Programmable Labels to Factory DefaultsFirst Keypad Options Second Keypad Options002 Zone Definitions Programming DescriptionsKeypad Function Key Programming O Programming Zones/PGMs Installer CodeSystem Times Master CodeThird System Options First System OptionsSecond System Options OFF Keypad Always Active. The keypad does not blank Fourth System OptionsTenth System Options Standard Time Set Clock Back Zone Loop Response Options134 Zone Attributes Daylight Saving Time Move Clock AheadCall Waiting Cancel String PGM Output TimerCross Zone/Police Code Timer No Activity Arm TimerFirst Communicator Options Communicator VariablesTest Transmission Time First Downloading Options OFF Closing Confirmation Disabled. The keypad does not beepSecond Communicator Options Third Communicator OptionsNumber of Rings to Answer On Downloading Access CodeDownloading Computer Phone Number Panel Identification CodeFollowing attributes are available for PGM Output Type Automatic Clock AdjustWay Audio Control Options applies to SCW9047 only Second International Options Delay Between Dialing AttemptsWireless Programming First International OptionsRestore Wireless Device Default Programming Wireless Module Placement TestInstaller Lockout Enable Installer Lockout DisableKeypad Programming Fire Alarm LabelsAlarm when Armed Event Message 069 Command Output LabelOption Description Future Use OFF Power LED is disabled. Option 6 has no effectFirst Keypad Options Second Keypad OptionsProgrammed LCD Message Duration Label ResetThird Keypad Options Programmed LCD MessageTesting & Troubleshooting Trouble 8 Loss of Clock/Date Trouble 4 Failure to CommunicateContact ID Appendix a Reporting Code FormatsSIA Format Automatic Zone Alarm/Restoral Codes Contact ID Zone Alarm/Restoral Event CodesAppendix B Communicator Format Options Residential Dial PagerNorth America Appendix C Regulatory Approvals InformationNew Zealand SIA False Alarm Reduction InstallationsEurope Exit Time Appendix D SIA False Alarm ReductionFormat Reporting Code/Event Appendix E 2-Way Audio Verification SCW9047 onlyBell/Buzzer Silent During 2-Way Audio Key Command DescriptionVOX Support Hang-up Auto-detectionPage FCC Compliance Statement