Appendix C: Regulatory Approvals Information
SIA False Alarm Reduction Installations
For a list of the defaults value programmed when the unit is shipped from the factory and for any other programming information refer to Appendix D: False Alarm Reduction.
Caution
Call Waiting Cancel (Section [382], Option 4) feature on a
Fire Alarm Verification feature (Auto Verified Fire Zone type [89]) is supported on the DSC Wireless Smoke Detector, Model WS4916. The fire alarm delay is 40s.
Notes
Programming at installation may be subordinate to other UL requirements for the intended application Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap) Cross zoning is not recommended for line security Installations nor is to be implemented on exit/entry zones.
There is a communication delay of 30 seconds in this control panel. It can be removed, or it can be increased up to 45 seconds at the option of the end user by consulting with the installer.
Do not duplicate any reporting codes. This applies for all communication formats other than SIA or CID sending automatic programmed reporting codes. The security system shall be installed with the sounding device activated and the communicator enabled for transmission using SIA or CID format.
Europe
This product is in conformity with:
EMC Directive 89/336/EEC based on results using harmonized stan- dards in accordance with article 10(5),
R&TTE Directive 1999/5/EC based on following Annex III of the direc- tive and
LVD Directive 73/23/EEC as amended by 93/68/EEC based on results using harmonized standards.
The product is labeled with the CE mark as proof of compliance with the above mentioned European Directives. Also a CE declaration of confor- mity (DoC) for this product can be found at www.dsc.com under Agency Listings section.
New Zealand
This DSC
PTC XXX / XX / XXX
This DSC
PTC XXX / XX / XXX
RN = X.X RN = X.X
The following is a list of warnings applicable when this equipment is connected to the New Zealand Telecom Network.
General Warning
The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum con- ditions for connection to its network. It indicates no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model, nor does it imply that any product is compatible with all of Telecom's network services.
Reverse Numbering (decadic signalling)
Decadic signalling should not be used as it is being progressively phased out of the network. DTMF dialling is 100% available and it should always be used.
Line Grabbing Equipment
This equipment is set up to carry out test calls at
The timing set for test calls from this equipment may be subject to 'drift'. If this proves to be inconvenient and your calls are interrupted, then the problem of timing should be discussed with the equipment installer. The matter should NOT be reported as a fault to Telecom Faults Service.
D.C. Line Feed to Other Devices
During dialling, this device unit does not provide DC voltage to the series port connection and this may cause loss of memory functions for the terminal devices (local telephone) connected to
General Operation (ringer sensitivity and loading)
This device only responds to Distinctive Alert cadences DA1 and DA2.