DSCover Satellite Products SCW904x manual Operation

Page 15

Section 5: Operation

Section 5: Operation

The LCD keypad displays the description and status indicator lights represent alarm functions and status. This section describes basic keypad commands. Refer to the User Guide for detailed descriptions of all keypad commands.

Press the [#] key to reset the keypad if an error has been made entering user codes or keypad commands

5.1 – Away Arming

The Ready light must be ON to arm the system. If the Ready light is OFF, ensure all protected doors and windows are secure or bypassed. To arm the system in the Away mode, either press and hold the Away function button for 2 seconds or enter a valid user code and leave the premises through a door programmed as Delay. Upon pressing a function key or entering an access code, the Armed light will turn ON. If the Audible Exit Delay option is enabled, the keypad will beep once every second during the exit delay (and three times a second during the last 10 seconds) to alert the user to leave. The Ready light will turn off when the Exit Delay ends.

5.2 – Stay Arming

The Ready light must be ON to arm the system. If the Ready light is OFF ensure all protected doors and windows are secure or bypassed. To arm the system in the Stay mode, either press and hold the Stay function button for 2 seconds or enter a valid user code and stay within the premises (do NOT violate a door programmed as Delay). Upon pressing a function key or entering an access code, the Armed light will turn ON. If the Stay function button is used, the keypad will not beep during the exit delay to avoid annoying the person staying in the premises. If a user code was used, the keypad will beep if the Audible Exit Delay option is enabled. The Ready light will turn off when the Exit Delay ends.

5.3 – Disarming

The user must enter through a door programmed as Delay. Upon entering, the keypad will emit a steady tone (and emit a pulsing tone during the last 10 seconds of entry delay) to alert the user to disarm the system. Enter a valid user code to disarm the system. If an alarm occurred while the panel was armed, the keypad will display ‘Alarm in Memory’. Press the [#] key to return the keypad to the Ready state.

5.4 – [

] Commands

 

The following is a list of the [

] commands available and a description of each:

[

][1]

Bypass (disarmed state)/Reactivate Stay/Away Zones (armed state)

[

][2]

Display Trouble Conditions

[

][3]

Display Alarm Memory

[

][4]

Door Chime Enable/Disable

[

][5]

User Code Programming

[

][6]

User Commands

[

][7][x]

Command Functions 1 – 2

[

][8]

Installer Programming

[

][9][code]

No-Entry Arming

[

][0]

Quick Arm (disarmed state)/Quick Exit (armed state)

[ ][1] – Bypass/Re-activate Stay/Away and Night Zones

Press [ ][1] to enter the bypass mode. If the Code Required for Bypass option is enabled, enter a valid user code. The keypad will display ‘Scroll to View Zones’. The keypad will display the programmed zone labels for the zones and include the letter ‘O’ in the bottom, right corner if the zone is violated or the letter ‘B’ if the zone is bypassed. Scroll to the appropriate zone and press the [ ] key to change the bypass status (or enter the 2-digit zone number). Once the correct zones are bypassed, press [#] to exit.

Additional Bypass Commands:

Bypass Recall: Press [99]. The keypad will recall the last group of zones that were bypassed

Clear Bypass: Press [00]. The keypad will clear the bypass on all zones.

Save Bypass: Press [95]. The keypad will save which zones are manually bypassed.

Recall Save: Press [91]. The keypad will recall the bypassed zones that were saved.

Re-activate Stay/Away and Night Zones:

Press [ ][1] when the system is armed in the Stay mode to change the armed status to Away mode or Night mode. The system will add the Stay/ Away zones back into the system after the exit delay time expires.

If any zones are programmed as Night Zones (zone definition 37) pressing [ ][1] will activate the Night mode instead of Away mode.

WWW.DIYALARMFORUM.COM11

Image 15
Contents Installation Guide Before Installing The Equipment Selecting a Suitable Location For The Alarm ControllerSafety Precautions required during Installation Table of Contents Page Technical Summary Installation & WiringEnsure connector key is oriented correctly InstallationWiring Burglary Zone Wiring ChartMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Verify Device Electronic Serial Number ESN Wireless Device EnrollmentEnter Wireless Enrollment Mode Activate Wireless DeviceZone Dependant Devices Detectors Zone Definitions Options 1 Template ProgrammingDigit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out Local Programming with PC-Link New Installations Refer to .1 Installation onExisting Installations Refer to .1 Installation on DLS ProgrammingOperation Program User Codes Alarm Memory DisplayDoor Chime Enable/Disable Trouble Display9User Code No-Entry Arming 7x Command Outputs 1&2Installer Programming Additional Keypad FunctionsAdvanced Programming Index to Programming Work Sheets and Descriptions Programming Work SheetsZone Definitions Programming WorksheetsFunction Key Programming Function Key OptionsKeypad Lockout Options Installer’s Code Master CodeSystem Times 009 I/O ProgrammingTenth System Options Second System OptionsThird System Options Fourth System OptionsZone Attributes Options 10-13 are reserved for Future Use Zone Loop Response OptionsNo Activity Arming Timer PGM Output TimerCross Zone/Police Code Timer No Activity Arming Pre-alert TimerPriority Alarm and Restoral Reporting Codes Alarm Reporting Codes, ZonesAlarm Restoral Reporting Codes, Zones Miscellaneous Alarm Reporting CodesTamper Reporting Codes, Zones Tamper Restoral Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Tamper/Restore Communicator Call Directions Communicator Format OptionsOpening/Closing Communicator Call Directions Test Transmission Time of Day System Maintenance Communicator Call DirectionsSystem Test Transmissions Communicator Call Directions Communication VariablesSecond Communicator Options Third Communicator OptionsDownloading Options Attribute Number of Rings To Answer OnInitiate PC-Link Downloading PGM Output AttributesFirst International Options Automatic Clock AdjustDelay Between Dialing Attempts 600 2-way Audio Control Options Applies to SCW9047 onlyWireless Supervisory Window Wireless programming Wireless Zone ProgrammingRestore Wireless Device Default Programming General Wireless OptionsWireless Module Placement Test Installer Lockout Enable Installer Lockout DisableLabel Programming Zone Local Keypad ProgrammingCommand Output #2 Label Fire Alarm LabelAlarm When Armed Event Message Command Output #1 LabelThird Keypad Options Reset Programmable Labels to Factory DefaultsFirst Keypad Options Second Keypad OptionsProgramming Descriptions Keypad Function Key Programming002 Zone Definitions O Programming Zones/PGMs Installer CodeSystem Times Master CodeFirst System Options Second System OptionsThird System Options Fourth System Options Tenth System OptionsOFF Keypad Always Active. The keypad does not blank Standard Time Set Clock Back Zone Loop Response Options134 Zone Attributes Daylight Saving Time Move Clock AheadCall Waiting Cancel String PGM Output TimerCross Zone/Police Code Timer No Activity Arm TimerCommunicator Variables Test Transmission TimeFirst Communicator Options First Downloading Options OFF Closing Confirmation Disabled. The keypad does not beepSecond Communicator Options Third Communicator OptionsNumber of Rings to Answer On Downloading Access CodeDownloading Computer Phone Number Panel Identification CodeAutomatic Clock Adjust Way Audio Control Options applies to SCW9047 onlyFollowing attributes are available for PGM Output Type Second International Options Delay Between Dialing AttemptsWireless Programming First International OptionsRestore Wireless Device Default Programming Wireless Module Placement TestInstaller Lockout Enable Installer Lockout DisableKeypad Programming Fire Alarm LabelsAlarm when Armed Event Message 069 Command Output LabelOption Description Future Use OFF Power LED is disabled. Option 6 has no effectFirst Keypad Options Second Keypad OptionsProgrammed LCD Message Duration Label ResetThird Keypad Options Programmed LCD MessageTesting & Troubleshooting Trouble 8 Loss of Clock/Date Trouble 4 Failure to CommunicateContact ID Appendix a Reporting Code FormatsSIA Format Automatic Zone Alarm/Restoral Codes Contact ID Zone Alarm/Restoral Event CodesAppendix B Communicator Format Options Residential Dial PagerNorth America Appendix C Regulatory Approvals InformationSIA False Alarm Reduction Installations EuropeNew Zealand Exit Time Appendix D SIA False Alarm ReductionFormat Reporting Code/Event Appendix E 2-Way Audio Verification SCW9047 onlyBell/Buzzer Silent During 2-Way Audio Key Command DescriptionVOX Support Hang-up Auto-detectionPage FCC Compliance Statement