•Installation •
IIIe Water piping — baseboard system
Figure 11a Baseboard system (finned tube or cast iron) — zone valve zoning
Zone 2
Zone 1
Baseboard system piping
Apply Figure 11a
The boiler internal “System circulator” can be used to circulate most
The boiler internal circulators must be left in the boiler. They cannot be removed for use a a zoning circulator. Provide a circulator for each zone when circulator zoning, and pipe the system as in Figure 11b.
Cold water fill
GV Boiler
85013a
Figure 11b Baseboard system (finned tube or cast iron) — circulator zoning
Zone 2
Zone 1 |
12" |
max |
Cold water
fill
Legend
1Boiler isolation valves
2Automatic air vent (with
3Diaphragm- or
4Zone valve
| 5 | Zone circulator |
| 6 | Flow/check valve |
GV Boiler | 7 | Hose bibb purge valve |
| ||
85017 | 8 | Boiler pressure/temperature gauge |