VIIf Start-upaltitude over 5,500 feet ONLY

Apply the following only when:

Altitude is over 5,500 feet above sea level.

You have obtained a high altitude kit (with tools needed) and installed high altitude air pressure switch per the instructions of manual Section IId.

Boiler has started correctly, following procedures on previous pages.

You will need the tools shown in Figure 20. Adjust the gas valve outlet pressure only if required as described in the following instructions.

Connect and adjust manometer

1.Remove boiler jacket top and front.

2.Close manual gas supply valve and turn off electrical power to boiler.

3.Using 3/16" allen wrench, remove outlet pressure tap plug from gas control and save plug (Figure 21).

4.Install 1/8" NPT-to-hose barb fitting in gas control outlet pressure tap as shown (Figure 21).

5.Position and zero manometer per manufacturer’s instructions.

Manometer must have at least 6" of tubing above the fluid level or fluid may be drawn into the gas control.

If manometer fluid is drawn into gas control body, gas control must be replaced. Fluid in valve will cause it to malfunction, possibly resulting in severe personal injury, death or substantial property damage.

6.Disconnect tube from hose barb on gas control vent tap. Connect tube end to tee hose fitting as shown in Figure 21. Then add length of hose from tee hose fitting to gas control vent tap.

7.Connect positive side manometer hose to top of the tee hose fitting (Figure 21).

8.Connect negative side manometer hose to hose barb fitting installed in gas control outlet pressure tap (Figure 21).

Check Gas Control Set Point

1.Open manual gas valve and turn on electrical power to boiler.

2.Start boiler and allow boiler to run for 5 minutes.

3.Read manometer. This is the gas control outlet pressure set point. If set point is between – 0.1" w.c. and – 0.3" w.c. go to step 7.

4.If gas control set point is not between – 0.1" w.c. and

0.3" w.c. remove cap on adjustment tower of gas control.

For White-Rodgers Model 36C valves, use

Figure 20 Tools required for gas valve outlet pressure measurement

85025

1U-tube manometer with tubing - Manometer provides a fine scale by slanting the manometer (Dwyer Model 1227 recommended).

2Tee hose fitting (provided in high altitude kit).

3³⁄₁₆" allen wrench.

4¹⁄₈" N.P.T.-to-hose barb fitting and wrench for same. (Fitting is provided in high altitude kit.)

5Phillips screwdriver.

6¹⁄₄" flat head screwdriver.

7Special tool for gas control adjustment cap removal for White-Rodgers 36C valves (provided in high altitude kit).

8Pliers.

pliers and special tool provided (Figure 20, items 7 and 8).

5.Turn gas control adjustment screw counter clockwise

to lower gas control set point to – 0.2" w.c.

6.Reinstall cap to gas control adjustment tower (with special tool for 36C valves).

7.Cycle boiler off and on several times to verify gas control set point. If set point does not remain between - 0.1" w.c. and – 0.3" w.c., readjust as necessary.

8.Close manual gas supply valve and turn off electrical power to boiler.

9.Remove 1/8" NPT-to-hose barb fitting in outlet pressure tap of gas control.

10.Apply pipe sealant to outlet pressure tap plug and reinstall using 3/16" allen wrench.

11.Remove tee hose fitting and added tube.

12.Reinstall hose on gas control vent tap hose barb.

13.Open manual gas supply valve and turn on electrical power to boiler.

46

Part number 550-141-850/0699

Image 46
Contents Gold GV How it works Gold GV Water boiler Series Hazard definitions Installer User Please read before proceedingBoiler operation When servicing boilerBoiler water Contents Contents Ia Prepare boiler location overview Overview of this sectionInstallations must follow these codes Ib Prepare boiler location codes & altitudeLarge space Ic Prepare boiler location clearancesClearance options Small spaceFlooring and foundation Residential garage installationPrecautions FlooringRemoving from existing vent Id Prepare boiler location vent systemGV special vent system Ie Prepare boiler location contamination Air contaminationIf Prepare boiler location air openings Special considerations GV in small space less than aloneIIa Prepare boiler overview IIb Prepare boiler vent starter tee & drainScrew hole Base rail Insert Cpvc elbow Natural gas Plate installationIIc Prepare boiler orifice plate PropaneBottom side of boiler front section When required IId Prepare boiler high altitude kitAltitudes above 5,500 feet only White Hose RedIIe Prepare boiler place in position Rotate Prepare boiler for test Fig IIf Prepare boiler pressure testPerform hydrostatic pressure test Fill and pressure testPiping connections for hydrostatic test IIIa Water piping overview For heating system with See pages 27 30Install relief valve IIIb Water piping relief valveAir separator IIIc Water piping boiler connectionsSupply & return connections Expansion tankPiping closed IIId Water piping all systems Zoning with circulatorsIIIe Water piping baseboard system Baseboard system pipingIIIf Water piping radiator system Radiator system pipingIIIg Water piping single-zone radiant or heat pump system IIIh Water piping multi-zone radiant system Outdoor reset controlMulti-zone radiant heating system piping IIIi Water piping snow melt system Manual bypass valves for fixed temp operation onlyIIIj Water piping water chiller systems Water chiller systemsIV Venting and combustion air Gas piping Connecting gas supply piping to boilerPropane Gas Feet Wiring connections VI Field wiringElectrical installation must comply with ThermostatsField wiring Factory wiring VIIb Start-up preparation Freeze protection when usedVIIa Start-up overview Verify water chemistryCheck for gas leaks VIIb Start-up preparationVerify gas/air orifice plate Fill the system with waterPerform final checks before starting boiler VIIc Start-up read SectionVIId Start-up to operate boiler Start the boilerVIId Start-up operate boiler VIIe Start-up if boiler doesn’t startVIIf Start-up altitude over 5,500 feet only Connect and adjust manometerCheck Gas Control Set Point At Least Inches VIIIa Check-out procedure overview Check-out procedure checklistVIIIb Check-out procedure checklist Shows the ladder wiring diagram for the GV series 3 boiler IXa Operation overviewIXb Operation sequence StepsIXb Operation wiring diagrams Ladder diagram legendGCM For Your Safety Read Before Operating IXc Operation lighting instructionsWhite-Rodgers gas valve model 36E Xa Service and maintenance overview Xb Service and maintenance schedule Service technicianXc Service & maintenance annual start-up Annual start-up only by qualified service technicianStart-up Xc Service & maint. annual start-upcont Annual start-up check/testGauges Expansion tankIgniter Boiler relief valve Annual start-up owner reviewReview with owner Condensate drain line Check valve assembly To remove the blower assembly Igniter XIa Troubleshooting overview Before troubleshooting XIb Troubleshooting proceduresCheck the following XIc Troubleshooting air pressure switch Checking the air pressure switchIgniter XId Troubleshooting servicing tipsBlower Housing Gas ValveXIe Troubleshooting control module Control ModulePower XIf Troubleshooting common problems Symptom Common Causes Possible CorrectionsSymptom Common Causes Possible Corrections XIg Troubleshooting GCM lights Chart 1 Troubleshooting Power light statusChart 2 Tstat Circ & Power lights flashing Chart 3 Limit & Power lights flashing Chart 4 Pres Switch & Power lights flashing Chart 5 Flame & Power lights flashing Chart 6 Tstat Circ light flashing and Power light on steady Chart 7 Limit light flashing and Power light on steady Is thermostat circuit closed continuity across wires? XIIa Replacement parts overview XIIb Replacement parts accessory bag Water trim bag assembly #1XIIc Replacement parts section assembly Description Model Weil-McLain Number Part number85041 XIId Replacement parts jacket assembly 422-200-22885042 XIIe Replacement parts Blower assembly 382-200-340Vent starter tee not included XIIf Replacement parts trim assembly Description Weil-McLain Number Part number85048 XIIg Replacement parts interior panel Interior panel Xiii Dimensions and ratings NumberDOE Gold GV Water boiler Series