Hearth and Home Technologies PALOMA-GY, PALOMA-GR, PALOMA-BL, PALOMA-BZ Table of Contents

Page 3

Table of Contents

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Glass Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 4 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 4 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 H. Requirements for the Commonwealth of Massachusetts. . 5

2 Getting Started

A. Design and Installation Considerations . . . . . . . . . . . . . . . 6

B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 6

C. Inspect Appliance and Components. . . . . . . . . . . . . . . . . . 6

3 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . . 7 B. Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . 7 C. Optional Stone Surround Installed . . . . . . . . . . . . . . . . . . . 8

4 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . . 9

5 Vent Information

A. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 B. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 C. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 D. How to Use the Vent Graph . . . . . . . . . . . . . . . . . . . . . . . 12 E. Venting Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 F. Horizontal Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 G. Vertical Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 H. Cathedral Ceiling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 I. Class A Metal Chimney . . . . . . . . . . . . . . . . . . . . . . . . . . 20 J. Existing Masonry Chimney. . . . . . . . . . . . . . . . . . . . . . . . 21 K. Slim Line Wall Thimble . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

6 Gas Information

A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 B. Converting to LP Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 C. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 D. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

7 Electrical Information

A. Recommendation for Wire . . . . . . . . . . . . . . . . . . . . . . . . 30 B. Connecting to the Appliance. . . . . . . . . . . . . . . . . . . . . . . 30 C. IntelliFire® Ignition System Wiring . . . . . . . . . . . . . . . . . . 30 D. Loss of Power and Battery Backup Usage. . . . . . . . . . . . 31 E. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 32

8 Appliance Setup

A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 33 B. Unbolting Appliance from the Pallet . . . . . . . . . . . . . . . . . 33 C. Leveling and Lagging Down the Appliance . . . . . . . . . . . 34 D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 E. Top to Rear Vent Conversion . . . . . . . . . . . . . . . . . . . . . . 35 F. Shutter Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 G. Installing the Vent Restrictor. . . . . . . . . . . . . . . . . . . . . . . 36 H. Installing the Baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 I. Positioning the Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 J. Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 K. Optional Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 L. Remote Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 M. Front Door Glass Assembly Installation . . . . . . . . . . . . . . 44 N. Inner Glass Door Assembly Replacement . . . . . . . . . . . . 44

9 Operating Instructions

A. Before Lighting Appliance. . . . . . . . . . . . . . . . . . . . . . . . . 45 B. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 C. Lighting Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 D. After Appliance is Lit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 E. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 47

10 Troubleshooting

A. Intellifire Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . 48

11 Maintaining and Servicing Appliance

A. Maintenance Tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

12 Reference Materials

A. Appliance Dimension Diagram Without Stone Surround . 52

B. Appliance Dimension Diagram With Stone Surround. . . . 53

C. Vent Components Diagram . . . . . . . . . . . . . . . . . . . . . . . 54

D. Vent Components List . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

E. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

F. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . 60

G. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

= Contains updated information.

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

3

Image 3
Contents Hot glass will cause burns ModelsWhat to do if you smell gas Do DiscardnotHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Model Framing and ClearancesSelecting Appliance Location Clearances to CombustiblesPaloma Surround Optional Stone Surround InstalledTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsException for Rear Vent KIT Snorkel Kit SLK How to Use the Vent GraphSNKD, Horizontal Installation Venting GuidelinesFemale Locking Lugs Male Locking Horizontal Termination203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Converting to LP Gas Procedure for ConversionGas Information Fuel ConversionsReattach Pilot Shield Gas Pressures Verify the performance of the ignition systemPressure Natural Gas Propane Check for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance IntelliFire Ignition System WiringLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalAppliance Setup Remove Shipping MaterialsUnbolting Appliance from the Pallet Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentPositioning the Logs Installing the BaffleInstallation precautions Mineral WoolOptional Blower Black Wires Recommended operating procedures Variable Remote Controls Installing flame control solenoidRemote receiver RED Orange Blue Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationOperating Instructions Before Lighting ApplianceControls Final inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Appliance IPI IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksLocation Inches Millimeter Appliance Dimension Diagram Without Stone SurroundReference Materials Hearth PadAppliance Dimensions with Stone Surround Appliance Dimension Diagram With Stone SurroundSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListService Parts Log Set AssemblyDescription Comments Part Number Service Parts ListStocked At DepotStocked Paloma Bottom Plate AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information