Hearth and Home Technologies PALOMA-BL, PALOMA-GR, PALOMA-BZ, PALOMA-GY flame has been lit, flame

Page 49

Intellifire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. (Continued) Pilot lights

c. Module is not grounded.

Verify that module is securely grounded to metal chassis

but continues to spark,

 

of appliance. Verify that wire harness is firmly connected to

and main burner will not

 

module.

ignite. (If the pilot contin-

 

 

d. Damaged pilot assembly or dirty sensor

Verify that ceramic insulator around the sensor rod is not

ues to spark after the pilot

rod.

cracked, damaged, or loose. Verify connection from sensor

flame has been lit, flame

 

rod to white sensor wire. Clean sensor rod with emery cloth

rectification has not oc-

 

 

to remove any contaminants that may have accumulated

curred.)

 

 

on sensor rod. Verify continuity with a multimeter with

 

 

 

 

ohms set at lowest range.

 

 

 

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF posi-

 

 

tion. Remove ignitor wire “I” from module. Place ON/OFF

 

 

Rocker switch or wall switch in ON position. Hold ground

 

 

wire about 3/16 inch away from “I” terminal on module. If

 

 

there is no spark at “I” terminal module must be replaced.

 

 

If there is a spark at “I” terminal, module is fine. Inspect

 

 

pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

4. Pilot sparks, but Pilot

a. Correct gas supply.

Verify that incoming gas line ball valve is “open”. Verify that

will not light.

 

inlet pressure reading is within acceptable limits, inlet pres-

 

 

sure must not exceed 14 in. W.C.

 

 

 

 

b. Ignitor gap is too large.

Verify that spark gap from ignitor to pilot hood is .17 in. or

 

 

1/8 in.

 

 

 

 

c. Module is not grounded.

Verify module is securely grounded to metal chassis of

 

 

appliance.

 

 

 

 

d. Module voltage output / Valve/Pilot

Verify battery voltage is at least 2.7 volts. Replace batteries

 

solenoid ohms readings.

if voltage is below 2.7.

 

 

 

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

49

Image 49
Contents What to do if you smell gas ModelsDo Discardnot Hot glass will cause burnsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Selecting Appliance Location Framing and ClearancesClearances to Combustibles ModelPaloma Surround Optional Stone Surround InstalledVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsSNKD, Horizontal Installation How to Use the Vent GraphVenting Guidelines Exception for Rear Vent KIT Snorkel Kit SLKFemale Locking Lugs Male Locking Horizontal Termination203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Gas Information Procedure for ConversionFuel Conversions Converting to LP GasReattach Pilot Shield Verify the performance of the ignition system Gas PressuresPressure Natural Gas Propane Check for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalRemove Shipping Materials Appliance SetupUnbolting Appliance from the Pallet Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentPositioning the Logs Installing the BaffleMineral Wool Installation precautionsOptional Blower Black Wires Recommended operating procedures Variable Installing flame control solenoid Remote ControlsRemote receiver RED Orange Blue Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationBefore Lighting Appliance Operating InstructionsControls On position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension Diagram Without Stone SurroundHearth Pad Location Inches MillimeterAppliance Dimensions with Stone Surround Appliance Dimension Diagram With Stone SurroundSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListService Parts Log Set AssemblyStocked Service Parts ListAt Depot Description Comments Part NumberStocked Paloma Bottom Plate AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information