21.Place one piece grommet over pilot wires and supply tube. Slide and snap into mating rectangular slot. Make sure it fits securely. See Figure 6.6.
Figure 6.6
22.Light the pilot and burner and use a commercially available,
23.Reinstall the logs by following the log placement instructions.
24.Reinstall the inner glass door assembly and the front door assembly.
25.Turn on the appliance to check for proper burner flame pattern.
26.Verify that the signed and dated conversion plate has been added to the appliance.
Verify the performance of the ignition system:
1.Verify pilot sparks, pilot lights, pilot stops sparking, and the main burner turns "ON".
2.Turn the appliance "OFF". Verify that both the pilot and burner turn "OFF".
3.Repeat Step 1 above.
4.With the burner "ON", remove the green wire con- nected to the valve. The main burner should shut "OFF".
5.Reattach the green wire to the valve, and the main burner should turn back "ON".
6.With the main burner "ON", remove the orange wire connected to the valve. The pilot and burner should go out, and the pilot will start to spark.
7.Turn the appliance "OFF" and reattach the orange wire to the valve.
WARNING
Fire Risk. Explosion Risk.
• Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed.
WARNING
Fire Risk. Explosion Risk.
• If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
•The qualified service agency is responsible for the proper installation of this conversion kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
C.Gas Pressures
Proper input pressures are required for optimum appli- ance performance. Gas line sizing requirements need to be made following NFPA54.
WARNING
Fire Risk. Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.
•Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.
WARNING
Verify inlet pressures.
• High pressure may cause overfire condition.
• Low pressure may cause explosion.
•Verify minimum pressures when other household gas appliances are operating.
Install regulator upstream of valve if line pressure is greater than 1/2 psig.
Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other household gas appliances are operating.
Pressure | Natural Gas | Propane | |
Minimum inlet pressure | 5.0 inches | 11.0 inches | |
w.c. | w.c. | ||
| |||
Maximum inlet gas pressure | 7.0 inches | 14.0 inches | |
w.c. | w.c. | ||
| |||
Manifold pressure | 3.5 inches | 10.0 inches | |
w.c. | w.c. | ||
|
28 | Heat & Glo • Paloma • |