Hearth and Home Technologies PALOMA-GR, PALOMA-BL Front Door Glass Assembly Installation

Page 44

M. Front Door Glass Assembly Installation

Remove the front door assembly by pulling bottom of front away from appliance and lifting it off of the spring-loaded latches on top of the appliance (see Figure 8.35).

Figure 8.35

Position the four flat 1/4 in. (6 mm) spacer washers on the front door so that the four mounting screws pass through them. Position the glass over the front door.

Install the four protective barrels into the glass and the four nylon washers on top of the glass.

From inside the door front, pass the screws through to the outside and thread on the caps until tight. See Figure 8.36.

CAP AND BARREL FASTENER SYSTEM

 

Nylon washer on back

Screw

and front of glass

 

 

Finishing Cap

 

Protective barrel sleeve

 

through hole in the glass

of side Back door front

Figure 8.36

N. Inner Glass Door Assembly Replacement

Turn the appliance OFF and let it cool down before replac- ing the inner glass door assembly.

With the front door assembly removed from the appliance, remove the inner glass door assembly by disengaging the spring-loaded latches at the bottom of the appliance and lifting off of the two spring-loaded latches at the top of the appliance.

Replace with a new inner glass door assembly.

Figure 8.37 Complete Assembly

WARNING

Handle glass doors with care.

• Inspect the gasket to ensure it is undamaged.

• Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass door assembly as a complete appliance.

44

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

Image 44
Contents Models What to do if you smell gasDo Discardnot Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Framing and Clearances Selecting Appliance LocationClearances to Combustibles ModelOptional Stone Surround Installed Paloma SurroundSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph SNKD, Horizontal InstallationVenting Guidelines Exception for Rear Vent KIT Snorkel Kit SLKHorizontal Termination Female Locking Lugs Male Locking203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type aTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble FIG. C Minimum Clearance Procedure for Conversion Gas InformationFuel Conversions Converting to LP GasReattach Pilot Shield Pressure Natural Gas Propane Gas PressuresVerify the performance of the ignition system Gas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Wall Switch Installation for Fan Optional Junction Box Wired to Wall SwitchUnbolting Appliance from the Pallet Appliance SetupRemove Shipping Materials Accessories Leveling and Lagging Down the ApplianceTop to Rear Vent Conversion Shutter Adjustment Installing the Vent RestrictorInstalling the Baffle Positioning the LogsOptional Blower Installation precautionsMineral Wool Black Wires Recommended operating procedures Variable Remote receiver Remote ControlsInstalling flame control solenoid Wiring the flame control solenoid RED Orange BlueFront Door Glass Assembly Installation Inner Glass Door Assembly ReplacementControls Operating InstructionsBefore Lighting Appliance Turn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action flame has been lit, flame Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Without Stone Surround Reference MaterialsHearth Pad Location Inches MillimeterAppliance Dimension Diagram With Stone Surround Appliance Dimensions with Stone SurroundVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousLog Set Assembly Service PartsService Parts List StockedAt Depot Description Comments Part NumberStocked Bottom Plate Assembly PalomaCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information