Attach the ground clip to the control panel. Attach the ground wire extension to the ground clip. Attach the the blower ground wire to the ground wire extension.
Figure 8.28
Plug the blower cord into the FAN outlet on the junction box. Refer to Figure 8.29, on the next page.
Push excess wires neatly towards the rear of the appliance.
Slide the blower into the bracket as indicated. Ensure the blower is pushed back into the bracket to allow the replacement of the lower access door. The magnet strips located on the blower feet are designed to hold the blower in place. See Figure 8.28.
Figure 8.29
Reattach the switch bracket with the two screws previously removed.
Connect the variable speed control and the temperature sensor switch to the short lead wires of the junction box by plugging in the male and female connectors. See Figure 8.31, on the next page).
Plug appliance in. Turn the
Recommended operating procedures
Ignite the fire in the appliance with the variable speed control switch in an "ON" position. The fan will automati- cally turn on when the temperature sensor switch closes at approximately 110 degrees Fahrenheit. Heated air should be delivered at the outlet grille. The fan will con- tinue to operate after the appliance is turned OFF until the sensor switch opens.
Various conditions (such as appliance model, type of appliance installation, outside air temperature vs. inside air temperature) can contribute to the length of the time the blower remains on after the appliance is turned OFF. The blower can be turned off manually with the speed control switch.