Hearth and Home Technologies PALOMA-GY, PALOMA-GR Loss of Power and Battery Backup Usage

Page 31

 

PLUG-IN 3V

 

 

TRANSFORMER

FLAME

 

 

ON/OFF

SPARKER/SENSOR

WALL

 

SWITCH

 

 

IGNITION

 

 

MODULE

 

 

(3V)

 

 

VALVE

BATTERY

 

PACK

 

 

REMOTE

NEUTRAL

GROUND

CONTROL HOT

 

 

TRANSFORMER

3 VAC

PLUG IN

JUNCTION BOX

Figure 7.2

IGNITION MODULE

3 VAC

IINTERMITTENT PILOT IGNITOR

S

 

WHT

 

BLACK

ORG

 

GROUND TO

 

APPLIANCE CHASSIS

 

RED

*

 

 

 

BRN

BRN

 

 

ORG

GRN

 

 

PIGGYBACK

 

ON/OFF SWITCH

 

VALVE

NOTE: Appliance will not operate unless properly grounded.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

D. Loss of Power and Battery Backup Usage

1.

Disconnect the power supply.

 

Unplug when

 

2.

Remove the front door assembly and lower access

 

using batteries

 

 

panel.

 

 

 

 

 

 

3.

Place two "D" cell batteries into

the battery holder.

 

 

 

(Figure 7.3)

 

 

 

4.

Turn on appliance and verify it is operational.

 

 

5.

Replace lower access panel and front door assembly.

 

 

 

CAUTION

 

 

 

If IPI battery back-up is installed:

 

 

 

• Do not install batteries if the backup mode may not be used

 

 

 

for extended time.

 

 

 

Batteries may leak.

 

 

 

Install batteries only when needed for power outage.

 

 

 

 

 

BATTERY LOCATION

 

 

 

 

Figure 7.3

 

 

 

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

31

Image 31
Contents Hot glass will cause burns ModelsWhat to do if you smell gas Do DiscardnotHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Model Framing and ClearancesSelecting Appliance Location Clearances to CombustiblesPaloma Surround Optional Stone Surround InstalledVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsException for Rear Vent KIT Snorkel Kit SLK How to Use the Vent GraphSNKD, Horizontal Installation Venting GuidelinesFemale Locking Lugs Male Locking Horizontal Termination203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Converting to LP Gas Procedure for ConversionGas Information Fuel ConversionsReattach Pilot Shield Verify the performance of the ignition system Gas PressuresPressure Natural Gas Propane Check for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance IntelliFire Ignition System WiringLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalRemove Shipping Materials Appliance SetupUnbolting Appliance from the Pallet Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentPositioning the Logs Installing the BaffleMineral Wool Installation precautionsOptional Blower Black Wires Recommended operating procedures Variable Installing flame control solenoid Remote ControlsRemote receiver RED Orange Blue Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationBefore Lighting Appliance Operating InstructionsControls Final inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Appliance IPI IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksLocation Inches Millimeter Appliance Dimension Diagram Without Stone SurroundReference Materials Hearth PadAppliance Dimensions with Stone Surround Appliance Dimension Diagram With Stone SurroundSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListService Parts Log Set AssemblyDescription Comments Part Number Service Parts ListStocked At DepotStocked Paloma Bottom Plate AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information