Hearth and Home Technologies PALOMA-GR, PALOMA-BL, PALOMA-BZ, PALOMA-GY Listing and Code Approvals

Page 4

1 Listing and Code Approvals

A. Appliance Certification

MODELS: Paloma

LABORATORY: Omni Test Laboratories, Inc.

TYPE: Vented Gas Fireplace Heater

STANDARD: ANSI Z21.88B-2003 • CSA 2.33-2003 • UL307B

CAN/CBA 2.17-M91

This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.

When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

D. High Altitude Installations

Omni-Test Laboratories, Inc. listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750ºC, shall be considered non-combustible materials.

B. Glass Specifications

This appliance is equipped with 5 mm ceramic glass behind the curved glass. Replace glass only with 5 mm ceramic glass. Please contact your dealer for replace- ment glass.

Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

C. BTU Specifications

Model

Maximum

Minimum

Orifice

*Steady

**P.4

(US or Canada)

Input

Input

Size

State

%

 

BTU/h

BTU/h

(DMS)

Efficiency %

 

Paloma (NG)

30,000

22,500

36

82.5

69

Paloma (LP)

28,000

22,650

52

81

71

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ig- nite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA

C22.1.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

*Maximum Vent Blower On **Canada Only

4

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

Image 4
Contents Models What to do if you smell gasDo Discardnot Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Framing and Clearances Selecting Appliance LocationClearances to Combustibles ModelOptional Stone Surround Installed Paloma SurroundVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph SNKD, Horizontal InstallationVenting Guidelines Exception for Rear Vent KIT Snorkel Kit SLKHorizontal Termination Female Locking Lugs Male Locking203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type aTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Slim Line Wall Thimble Installing Slim Line Trim Ring and Heat ShieldAssembling Slim Line Trim Ring and Heat Shield FIG. C Minimum Clearance Procedure for Conversion Gas InformationFuel Conversions Converting to LP GasReattach Pilot Shield Verify the performance of the ignition system Gas PressuresPressure Natural Gas Propane Gas Connection Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Wall Switch Installation for Fan Optional Junction Box Wired to Wall SwitchRemove Shipping Materials Appliance SetupUnbolting Appliance from the Pallet Accessories Leveling and Lagging Down the ApplianceTop to Rear Vent Conversion Shutter Adjustment Installing the Vent RestrictorInstalling the Baffle Positioning the LogsMineral Wool Installation precautionsOptional Blower Black Wires Recommended operating procedures Variable Installing flame control solenoid Remote ControlsRemote receiver Wiring the flame control solenoid RED Orange BlueFront Door Glass Assembly Installation Inner Glass Door Assembly ReplacementBefore Lighting Appliance Operating InstructionsControls Turn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance Tasks Inspect Maintenance TasksAppliance Dimension Diagram Without Stone Surround Reference MaterialsHearth Pad Location Inches MillimeterAppliance Dimension Diagram With Stone Surround Appliance Dimensions with Stone SurroundVent Components Diagram SLP Series Vent ComponentsVent Components List MiscellaneousLog Set Assembly Service PartsService Parts List StockedAt Depot Description Comments Part NumberStocked Bottom Plate Assembly PalomaCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information