Hearth and Home Technologies PALOMA-GY, PALOMA-GR, PALOMA-BL, PALOMA-BZ Top to Rear Vent Conversion

Page 35

E. Top to Rear Vent Conversion

Note: When installing this appliance in a rear vent configura- tion with no vertical rise, a Snorkel Kit must be used.

Kit Contents: Top cover (no hole); Back panel (with hole).

Tools Required: Power drill; #2 Phillips bit; 5/32 in. (4 mm) Allen wrench; 5/8 in. (16 mm) open end wrench; high-temp silicone sealant (optional).

1.Remove the front door assembly by lifting it off of the spring-loaded latches on top of the appliance. Remove the inner glass door by disengaging the spring-loaded latches at the bottom of the appliance and lifting it off of the two spring loaded latches at the top of the appli- ance.

2.Remove the top plate with hole and discard. (Figure 8.8).

Figure 8.8

3.Remove and retain the Allen head screws that hold the solid back panel in place. (Figure 8.9) Remove and discard the solid back panel.

PILOT ASSEMBLY

Figure 8.9

4.Remove the four screws from the DV adapter collar. (Figure 8.10) Set aside DV adapter collar and screws.

5.Remove the inner extension starter collar (Shown in Figure 8.10) and set aside.

INNER EXTENSION COLLAR

DV ADAPTER

Figure 8.10

6.Remove the four screws from the cover plate on rear of appliance. Retain screws. (see Figure 8.11).

Figure 8.11

7.Install the outer collar with gasket to the rear of appli- ance with screws previously removed. Install the inner extension starter collar. (Figure 8.12).

8.Install the new back panel (with hole) to the rear of appliance. Replace the allen head screws removed in Step 3 to hold the back panel in place. (Figure 8.12).

Figure 8.12

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

35

Image 35
Contents Hot glass will cause burns ModelsWhat to do if you smell gas Do DiscardnotHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Model Framing and ClearancesSelecting Appliance Location Clearances to CombustiblesPaloma Surround Optional Stone Surround InstalledSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsException for Rear Vent KIT Snorkel Kit SLK How to Use the Vent GraphSNKD, Horizontal Installation Venting GuidelinesFemale Locking Lugs Male Locking Horizontal Termination203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble FIG. C Minimum Clearance Converting to LP Gas Procedure for ConversionGas Information Fuel ConversionsReattach Pilot Shield Pressure Natural Gas Propane Gas PressuresVerify the performance of the ignition system Check for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance IntelliFire Ignition System WiringLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalUnbolting Appliance from the Pallet Appliance SetupRemove Shipping Materials Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentPositioning the Logs Installing the BaffleOptional Blower Installation precautionsMineral Wool Black Wires Recommended operating procedures Variable Remote receiver Remote ControlsInstalling flame control solenoid RED Orange Blue Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationControls Operating InstructionsBefore Lighting Appliance Final inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Appliance IPI IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksLocation Inches Millimeter Appliance Dimension Diagram Without Stone SurroundReference Materials Hearth PadAppliance Dimensions with Stone Surround Appliance Dimension Diagram With Stone SurroundSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListService Parts Log Set AssemblyDescription Comments Part Number Service Parts ListStocked At DepotStocked Paloma Bottom Plate AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information