Wiring the flame control solenoid:
Connect the two leads from the flame control solenoid to the orange leads from the receiver. See Figure 8.33.
REMOTE RECEIVER
IGNITION MODULE | INTERMITTENT |
3 VAC | PILOT IGNITOR |
NGEORA | NGEORA |
|
| I |
RED | RED | S |
TEIH
W
REMOTE
RECEIVER
TRANSFORMER
3 VAC
ORANGE
RED
ORANGE
BLUE
PLUG
IN
BLACK | RED |
BATTERY PACK
BRN | GROUND TO |
| |
FIREPLACE CHASSIS |
| ||
| BRN |
|
|
RED | RED JUMPER |
|
|
RED |
|
| |
WIRE TO | ORANGE | GREEN | |
REDRED BRN | BROWN | ||
|
|
| |
|
| VALVE |
|
PIGGYBACK |
|
| |
ON/OFF SWITCH |
|
|
JAM NUT
REGULATOR
TOWER
PLUNGER
| FLAME |
| CONTROL |
| SOLENOID |
ORANGE | ORANGE |
ORANGE
ORANGE
Figure 8.34 Remote Control IPI Wiring Diagram
Figure 8.33 Remote Receiver / Control Solenoid
Install a manometer into the pressure tap. Plug the remote receiver into the
Light the appliance as directed in Section 9 of this manual. Set the manifold pressure on the gas valve by rotating the flame control solenoid. Adjust until the reading on the manometer is 3.5 in. W.C. for natural gas or 10 in. W.C. for LP.
Tighten the jam nut to the face of the variable regulator body. See Figure 33 Turn the main gas knob on the gas valve OFF. Remove the manometer from the pressure tap and screw the tap closed.
Follow the instructions from the remote control kit to operate and program the remote control.