Hearth and Home Technologies PALOMA-BL, PALOMA-GR Appliance Dimension Diagram With Stone Surround

Page 53

B. Appliance Dimension Diagram With Stone Surround

A

 

 

 

 

 

B

 

 

 

 

 

 

 

D

 

 

 

 

E

 

 

F

 

C

 

 

 

 

 

 

 

 

 

Hearth Pad

 

 

 

 

 

 

 

 

 

Height includes 3/8 in (9.53 mm) hearth pad

 

 

 

 

G

 

 

Height includes 3/8 in (9.53 mm) hearth pad

 

Location

Inches

Millimeter

Location

Inches

Millimeter

A

29-5/8

753

E

16-7/8

428

B

24-3/8

620

F

34-5/8

879

C

30-1/4

768

G

44-5/16

1126

D

3-1/4

83

 

 

 

Figure 12.2 Appliance Dimensions with Stone Surround

 

 

 

 

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

53

Image 53
Contents What to do if you smell gas ModelsDo Discardnot Hot glass will cause burnsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Selecting Appliance Location Framing and ClearancesClearances to Combustibles ModelPaloma Surround Optional Stone Surround InstalledSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsSNKD, Horizontal Installation How to Use the Vent GraphVenting Guidelines Exception for Rear Vent KIT Snorkel Kit SLKFemale Locking Lugs Male Locking Horizontal Termination203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble FIG. C Minimum Clearance Gas Information Procedure for ConversionFuel Conversions Converting to LP GasReattach Pilot Shield Pressure Natural Gas Propane Gas PressuresVerify the performance of the ignition system Check for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalUnbolting Appliance from the Pallet Appliance SetupRemove Shipping Materials Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentPositioning the Logs Installing the BaffleOptional Blower Installation precautionsMineral Wool Black Wires Recommended operating procedures Variable Remote receiver Remote ControlsInstalling flame control solenoid RED Orange Blue Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationControls Operating InstructionsBefore Lighting Appliance On position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension Diagram Without Stone SurroundHearth Pad Location Inches MillimeterAppliance Dimensions with Stone Surround Appliance Dimension Diagram With Stone SurroundSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListService Parts Log Set AssemblyStocked Service Parts ListAt Depot Description Comments Part NumberStocked Paloma Bottom Plate AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information