Hearth and Home Technologies PALOMA-BL Requirements for the Commonwealth of Massachusetts

Page 5

Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H. Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equip- ment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure sep- arate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and

The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

Heat & Glo • Paloma • 7031-220 Rev. P • 10/08

5

Image 5
Contents What to do if you smell gas ModelsDo Discardnot Hot glass will cause burnsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Selecting Appliance Location Framing and ClearancesClearances to Combustibles ModelPaloma Surround Optional Stone Surround InstalledSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Venting Components Vent InformationUse of Elbows Measuring StandardsSNKD, Horizontal Installation How to Use the Vent GraphVenting Guidelines Exception for Rear Vent KIT Snorkel Kit SLKFemale Locking Lugs Male Locking Horizontal Termination203 mm 178 mm 152 mm Vinyl Siding Vertical Termination Hole as shown in Figure Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Existing Masonry ChimneyTo determine the length of flex needed, measure from Flex Liner Flex Coupler Sheet Metal Screws Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble FIG. C Minimum Clearance Gas Information Procedure for ConversionFuel Conversions Converting to LP GasReattach Pilot Shield Pressure Natural Gas Propane Gas PressuresVerify the performance of the ignition system Check for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireIntelliFire Ignition System Wiring Wire Size Max. LengthLoss of Power and Battery Backup Usage Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalUnbolting Appliance from the Pallet Appliance SetupRemove Shipping Materials Leveling and Lagging Down the Appliance AccessoriesTop to Rear Vent Conversion Installing the Vent Restrictor Shutter AdjustmentPositioning the Logs Installing the BaffleOptional Blower Installation precautionsMineral Wool Black Wires Recommended operating procedures Variable Remote receiver Remote ControlsInstalling flame control solenoid RED Orange Blue Wiring the flame control solenoidInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationControls Operating InstructionsBefore Lighting Appliance On position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action flame has been lit, flame Maintaining and Servicing Appliance Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension Diagram Without Stone SurroundHearth Pad Location Inches MillimeterAppliance Dimensions with Stone Surround Appliance Dimension Diagram With Stone SurroundSLP Series Vent Components Vent Components DiagramMiscellaneous Vent Components ListService Parts Log Set AssemblyStocked Service Parts ListAt Depot Description Comments Part NumberStocked Paloma Bottom Plate AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information