11.Using a 3/8 in. (10 mm) nut driver or wrench, remove the NG orifice and replace it with the LP orifice pro- vided in this kit (see Figure 6.3).
Figure 6.3
12.Unscrew the pilot tube fitting on the pilot and replace the orifice spud with the one included in the conver- sion kit (see Figure 6.4).
ORIFICE SPUD
PILOT TUBE
ASSEMBLY
Figure 6.4
13.Place the round LP label on the bottom base pan. Place the propane conversion plate adjacent to the existing rating plate.
Note: The qualified service agency installing this conversion MUST enter the day, month, and year, and sign the propane conversion plate added to the appliance.
14.Reinstall the bottom plate and valve assembly into the appliance. Reinstall the six hold down screws.
15.Reconnect the inlet gas line to the valve assembly and turn on the gas line valve. Check the incoming line for leaks.
16.Reconnect the electrical power supply.
17.Reconnect the orange wire to the valve assembly. This will allow for the pilot to turn on with the control switch in the "ON" position. Check all pilot line con- nections for leaks. (See Figure 6.4)
18.Use a commercially available,
WARNING
Shock or burn risk.
•Disconnect green wire from gas valve.
Failure to disconnect green wire could result in severe burns.
19.Reinstall the green wire on the valve.
20.Before reinstalling the burner, ensure that the shutter setting is fully open. Reattach pilot to pilot shield to burner (see Figure 6.5). Retighten the screw.
REATTACH
PILOT SHIELD
Figure 6.5