PDX Series
PDX SERVICE PROCEDURE III
Pressure Switch Testing and
Replacement
Exhaust Pressure Switch |
| WARNING | |
Replacement |
| ||
| 120 volt potential exposure. Use caution | ||
Step 1. | Position gas control power switch |
| to avoid personal injury. |
| to “OFF” position. |
|
|
Step 2. | Remove the three screws (Phillips screw driver) from control access cover on blower assembly and | ||
| remove cover (see photo 3). |
|
|
Step 3. | Disconnect the tubing and wires from inlet pressure switch. | ||
|
|
| Pressure Switch |
Step 4. | Carefully remove pressure | 3 | 4 |
|
| ||
| switch from blower |
|
|
| housing (see photo 4) |
|
|
|
|
| Slide pressure switch in direction |
|
|
| of arrow while tilting slightly away |
|
|
| from blower housing. |
Step 5. | Disconnect tubing from | 5 | 6 |
|
| ||
| pressure switch. |
|
|
| (see photo 5) |
|
|
Step 6. | Disconnect yellow wires |
|
|
| from pressure switch |
|
|
| (see photo 6) |
|
|
Step 7. Reconnect wires from step 5 to new pressure switch. Step 8. Reconnect tubing to new pressure switch.
Step 9. Carefully position pressure switch into blower housing. Step 10. Reconnect wires and tubing to inlet pressure switch.
Step 11. Position gas control power switch to “ON” position and verify proper heater operation. Step 12. Replace control access cover from step 2.
Page 18
18