Bradford-White Corp PDX250T6*F(BN, PDX75S70F(B, CX) Installation of Inner Door With Gasket

Page 36

PDX Series

PDX SERVICE PROCEDURE XIII

Inner Door/Gasket Removal, Inspection

Replacement and Reinstallation

Installation of Inner Door With Gasket.

Step 7. Clean any residual gasket residue or other debris from combustion chamber surface before installing the inner door/gasket assembly.

Step 8. Place the left side inner door into position first. Firmly position the radiused channel of the inner door aroundthe feedline. Using the 1/4” hex drive screws from step 3d, secure left side inner door in place. DO NOT OVER TIGHTEN SCREWS.

Step 9 Position thermocouple, pilot tube and Piezo wire against left side inner door flange gasket. DO

NOT ROUTE THROUGH RADIUSED

CHANNEL WITH FEEDLINE.

WARNING

Stripped fastener connections may allow

for seal breach of inner door. A seal breach may result in a fire or explosion causing property damage, personal injury or death. Do not over tighten screws in steps 8, 10 and 11.

If a fastener connection is stripped, contact the manufacturer listed on the water heater rating plate.

Igniter wire and pilot tube shown in proper position.

Radiused Channel

for Feedline

Page 36

36

Image 36
Contents Service Manual Denotes Warranty YearsTable of Contents PDX Series Introduction Tools Required for Service How to Use This ManualSpecifications PDX Series Control Timings Power up Sequence Sequence of OperationAbnormal Operation Pressure Switch/Blower Temperature Fault Troubleshooting Probable Cause Service Status ProcedureGreen LED Indicator LED StatusTroubleshooting LED Status Burner Inspection and Air Shutter Adjustment Cast Iron Burner Air Shutter AdjustmentAir Shutter Nut Burner Cleaning Burner Surface area Feedline nut Pilot tubing nut Port areaPilot Inspection, Testing and Replacement Igniter/flame Sense wireFeedline nut Pilot tubing nut Ferrule OrificeExhaust Pressure Switch Testing Volt potential exposure. Use cautionMaking voltage checks to avoid personal injury Exhaust Pressure Switch Replacement Slide pressure switch in directionFrom blower housing To avoid personal injuryInlet Pressure Switch Switch for blockage Is there blockage?To call for heat, this will start the blower SeeInlet Pressure Switch Replacement Remove screwsBlower Testing Volt potential exposure. Use caution whenBlower Installation Blower removalRemove exhaust Blower Cord Sets Blower Mounting ScrewsBlower Temperature Switch Testing Blower Temperature Switch Replacement Gas Control Testing Thermal Well TestingIf Control has gone into TCO lockout due to Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Removal From Thermal WellGas Control Assembly to Thermal Well Flammable Vapor Device Testing Safety Circuit Voltage Trace Wires as shown Control VAC Circuit TraceShown in photo Across black & white YDip Tube Inspection and Replacement Anode Inspection and Replacement Flue baffle Inner Door Removal Procedure Installation of Inner Door With Gasket Installation of inner door with gasket from Glossary of Terms Parts List Parts@bradfordwhite.com Techserv@bradfordwhite.com