PDX Series
PDX SERVICE PROCEDURE III
Pressure Switch Testing and
Replacement
Inlet Pressure Switch
WARNING
Testing120 volt potential exposure. Use caution making voltage checks to avoid personal injury.
Step 1. Position power switch on gas control to the “OFF” position.
Step 2. Remove the three screws (Phillips screw driver) from control access cover on blower assembly and remove cover (see photo 7).
Step 3. Remove wires from inlet pressure switch.
Exhaust
pressure switch
With steps 1,2 & 3
complete.
Use a
Are switch contacts closed?
Y
Position gas valve power switch to the “ON” position and adjust thermostat
to call for heat, this will start the blower.
Check with
Y
7
Inlet pressure
switch
Check tubing and pressure
N tap on switch for blockage. Is there blockage?
|
|
|
|
|
| Y |
| |
|
|
|
|
|
|
|
| |
|
|
|
|
| Clear blockage |
| ||
|
| Y |
|
|
| |||
|
|
|
|
| Y |
| ||
|
|
|
|
|
| |||
| Check tubing and |
|
|
|
| |||
|
|
| Is vent |
| ||||
N | pressure tap on | N | N | |||||
system | ||||||||
| switch for blockage. |
|
|
|
Is there blockage? | blocked |
|
N | Replace switch |
| (see page 20) |
Is vent system length
within vent table Y specifications listed on page 7
N
Reconfigure vent
system to be
Inlet pressure
switch wire
leads (found inside cover)
Y
See blower testing
(page 21)
Is blower OK?
N
Correct blower
Switch contacts are OK. See exhaust pressure switch testing (page 17)
compliant with
vent tables.
problem.
Page 19
19