PDX SERVICE PROCEDURE VIII
Safety Circuit Voltage Trace
Safety Circuit Voltage Trace
NOTE: This procedure assumes a cool tank.
WARNING
120 volt potential exposure. Use caution
making voltage checks to avoid personal injury.
27
Step 2. Remove three screws (Phillips Screw driver) from control access cover on blower and remove cover (see photo 26).
Position gas control switch to the “ON” |
|
|
| ||
position and adjust thermostat dial to call |
|
|
| ||
for heat, Is there 10 to 13 VAC between | Is LED on gas valve flashing |
| |||
red wire leading to blower temperature N | Y | ||||
|
|
| the “heartbeat” code |
| |
switch and green ground wire? |
| ||||
(alternating bright/dim) |
| ||||
Blower must be running during this |
| ||||
|
|
| |||
voltage check. |
| N |
| ||
|
| ||||
(see photo 28) |
|
| |||
|
|
| |||
| Y | Verify 120VAC to gas |
| ||
|
| ||||
|
|
|
| ||
|
|
| control (see page 30) |
| |
|
|
|
|
|
|
No voltage from gas control,
call for technical support.
Is there 10 to 13 VAC between yellow | Is there continuity |
| Check for loose or | |||
wire leading from pressure switch and N | through blower | Y | broken wire | |||
green ground wire? |
| temperature switch? |
| connection at switch | ||
(see photo 28) | (see page 21) |
| terminals | |||
| Y |
| N |
|
| |
|
|
|
| |||
|
|
| Determine cause of blower |
| ||
|
| Correct igniter/ | temperature switch |
|
| |
|
| sensor problem. | activation and correct. |
|
| |
|
|
|
|
|
|
|
Do you hear or can you N see the igniter sparking?
Y
Safety circuit voltage is OK.
If burner does not light, observe LED flash code on gas valve and refer to troubleshooting section on page 12
Check igniter/sensor | Y | Faulty cord set or | |
(see page 16) | |||
| gas control. | ||
is igniter/sensor OK? |
| ||
| Green ground wire | ||
|
| ||
28 |
|
| |
|
| Red wire leading to | |
|
| blower temp. switch |
Yellow wire leading from pressure switch
Page 30