PDX Series
PDX SERVICE PROCEDURE III
Pressure Switch Testing and
Replacement
Inlet Pressure Switch | WARNING | ||
Replacement | |||
120 volt potential exposure. Use caution | |||
Step 1. | Position gas control power switch | to avoid personal injury. | |
| to “OFF” position. |
| |
Step 2. | Remove the three screws (Phillips screw driver) from control access cover on blower assembly and | ||
| remove cover (see photo 8). |
| |
Step 3. | Disconnect the tubing from the pressure switch (see photo 9). | ||
| 8 | 9 |
Step 4. Remove inlet pressure switch from blower access cover. (see photo 10).
Step 5. Disconnect yellow wires from pressure switch (see photo 11).
Step 6. Attach new inlet pressure switch to blower control access cover.
Remove screws |
|
|
to remove inlet | 10 |
|
pressure switch | 11 | |
|
|
Step 7. Reconnect wires from step 5 to new pressure switch. Step 8. Reconnect tubing to new pressure switch.
Step 9. Replace control access cover from step 2.
Step 10. Position gas control power switch to “ON” position and verify proper heater operation.