PDX Series
PDX SERVICE PROCEDURE III
Pressure Switch Testing and
Replacement
Exhaust Pressure Switch | WARNING | ||
Testing | |||
120 volt potential exposure. Use caution | |||
Step 1. | Position power switch on gas control | making voltage checks to avoid personal injury. | |
| to the “OFF” position. |
| |
Step 2. | Remove the three screws (Phillips screw driver) from control access cover on blower assembly and | ||
| remove cover (see photo 1). |
| |
Step 3. | Remove tubing and wires from inlet pressure switch. | ||
Step 4. | Carefully remove pressure switch from blower housing (see photo 2) |
Exhaust |
|
pressure switch | 1 |
Inlet pressure switch
Pressure switch
wire leads
With steps 1,2,3 & 4
complete,
disconnect wire leads from
pressure switch.
Use a |
|
|
|
|
|
|
|
|
|
| ||
ohms setting. With blower off, |
|
|
|
|
| Check tubing and pressure | ||||||
check across pressure |
| N |
|
|
| |||||||
|
|
|
|
| tap on switch for blockage. | |||||||
switch terminals. |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| Is there blockage? | |||||
Are switch contacts open? |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
(no electrical continuity) |
|
|
|
|
|
|
|
| Y |
| ||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||
| Y |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Clear blockage |
| ||||
|
|
|
|
|
|
|
|
|
| |||
Position gas valve power |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
switch to the “ON” position |
|
|
| Y |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||||
and adjust thermostat |
|
|
|
|
|
| Y |
| ||||
|
|
|
|
|
|
|
|
| ||||
to call for heat, |
|
| Check tubing and |
|
|
|
| |||||
|
|
|
| Is vent |
| |||||||
this will start the blower. | N | pressure tap on | N | N | ||||||||
system | ||||||||||||
Check with |
|
| switch for blockage. |
|
|
| ||||||
|
|
|
| blocked |
| |||||||
pressure switch contacts |
|
| Is there blockage? |
|
|
| ||||||
|
|
|
|
|
|
|
close with blower running
with the switch in the
vertical postition?
Y
Switch contacts are OK. See safety circuit trace (page 30)
2
Pressure Switch
Slide pressure switch in direction of arrow while tilting slightly away from blower housing.
N | Replace switch |
| (see page 18) |
Is vent system length |
|
| Y | ||
| See blower testing | ||||
within vent table | Y | ||||
(page 21) | |||||
specifications |
| ||||
| Is blower OK? | ||||
listed on page 7 |
| ||||
|
| N | |||
|
| ||||
| N |
|
| ||
|
|
| |||
|
|
|
| ||
|
|
|
|
| |
Reconfigure vent |
| Correct blower | |||
system to be |
| ||||
compliant with |
| problem. | |||
vent tables. |
|
|
|
Page 17
17