PDX Series
PDX SERVICE PROCEDURE VII
Flammable Vapors Sensor Testing
Flammable Vapor Device Testing
Step 1. Position power switch on gas control to the “OFF” position.
Step 2. Disconnect flammable vapor sensor from gas control.
Step 3. Using a
Resistance must be within 3,000 ohms and 48,000 ohms. If outside of this range replace flammable vapor sensor.
Electronic “pin type” Meter Probes
Flammable Vapor
Sensor
CAUTION |
DO NOT use standard multimeter probes for this test. |
Doing so will damage connector. Use special electronic |
“pin type” probes or small diameter wire pins inserted |
into connector. |
Flammable Vapor
Sensor