Bradford-White Corp PDX250T6*F(BN, PDX75S70F(B, CX) Determine Water Temperature Inside Tank

Page 26

PDX Series

PDX SERVICE PROCEDURE VI

Gas Control/Thermal Well Testing and

Replacement

WARNING

Stored water may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

Determine Water Temperature Inside Tank

Note: It is important to understand once the resistance for the thermal well is determined from page 25, water flow through the heater should not occur. Prior to performing the steps below, turn off the cold water supply to the water heater. This will prevent cold water flow into the tank affecting the resistance value of thermal well.

Step 1. Position gas control power switch to “OFF” position.

Step 2. Draw approximately 4 gallons of water from drain valve into a container and discard. Draw an additional gallon and immediately measure water temperature using an accurate thermometer. It may be necessary to open a hot water faucet to allow heater to drain.

Step 3. Using the chart below, determine correct resistance value for the water temperature from step 2.

Example:

If temperature of water is 84°F, then the resistance through the sensor would be

 

8449 (see shaded area). NOTE: Sensor resistance increases as the temperature

 

falls.

 

 

 

 

 

 

 

 

 

 

 

Sensor Resistance at Various Temperatures

 

 

 

 

 

 

 

In Degrees F

 

 

 

 

°F

0

1

2

3

4

5

6

7

8

9

40

26109

25400

24712

24045

23399

22771

22163

21573

21000

20445

50

19906

19383

18876

18383

17905

17440

16990

16553

16128

15715

60

15314

14925

14548

14180

13823

13477

13140

12812

12494

12185

70

11884

11592

11308

11032

10763

10502

10248

1000

9760

9526

80

9299

9078

8862

8653

8449

8250

8057

7869

7685

7507

90

7333

7165

7000

6839

6683

6531

6383

6238

6098

5961

100

5827

5697

5570

5446

5326

5208

5094

4982

4873

4767

110

4663

4562

4464

4368

4274

4183

4094

4006

3922

3839

120

3758

3679

3602

3527

3453

3382

3312

3244

3177

3112

130

3048

2986

2925

2866

2808

2752

2697

2643

2590

2538

140

2488

2439

2391

2344

2298

2253

2209

2166

2124

2083

150

2043

2004

1966

1928

1891

1856

1820

1786

1753

1720

160

1688

1656

1625

1595

1566

1537

1509

1481

1454

1427

170

1402

1376

1351

1327

1303

1280

1257

1235

1213

1191

180

1170

1150

1129

1110

1090

1071

1953

1035

1017

999

190

982

965

949

933

917

901

886

871

857

842

200

828

814

801

788

775

762

749

737

725

713

Page 26

26

Image 26
Contents Service Manual Denotes Warranty YearsTable of Contents PDX Series Introduction Tools Required for Service How to Use This ManualSpecifications PDX Series Control Timings Power up Sequence Sequence of OperationAbnormal Operation Pressure Switch/Blower Temperature Fault Green LED Indicator TroubleshootingProbable Cause Service Status Procedure LED StatusTroubleshooting LED Status Air Shutter Nut Burner Inspection and Air Shutter AdjustmentCast Iron Burner Air Shutter Adjustment Burner Cleaning Burner Surface area Feedline nut Pilot tubing nut Port areaFeedline nut Pilot tubing nut Ferrule Pilot Inspection, Testing and ReplacementIgniter/flame Sense wire OrificeMaking voltage checks to avoid personal injury Exhaust Pressure Switch TestingVolt potential exposure. Use caution From blower housing Exhaust Pressure Switch ReplacementSlide pressure switch in direction To avoid personal injuryTo call for heat, this will start the blower Inlet Pressure SwitchSwitch for blockage Is there blockage? SeeInlet Pressure Switch Replacement Remove screwsBlower Testing Volt potential exposure. Use caution whenRemove exhaust Blower InstallationBlower removal Blower Cord Sets Blower Mounting ScrewsBlower Temperature Switch Testing Blower Temperature Switch Replacement If Control has gone into TCO lockout due to Gas Control TestingThermal Well Testing Determine Water Temperature Inside Tank Sensor Resistance at Various TemperaturesGas Control & Thermal Well Removal From Water Heater Gas Control Removal From Thermal WellGas Control Assembly to Thermal Well Flammable Vapor Device Testing Safety Circuit Voltage Trace Shown in photo Wires as shown ControlVAC Circuit Trace Across black & white YDip Tube Inspection and Replacement Anode Inspection and Replacement Flue baffle Inner Door Removal Procedure Installation of Inner Door With Gasket Installation of inner door with gasket from Glossary of Terms Parts List Parts@bradfordwhite.com Techserv@bradfordwhite.com