Bradford-White Corp PDX75S70F(B, CX) VAC Circuit Trace, Shown in photo, Across black & white Y

Page 31

PDX Series

PDX SERVICE PROCEDURE IX

120 VAC Trace

120 VAC Circuit Trace

WARNING

120 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

Step 1. Verify 120VAC and proper polarity at wall outlet.

Step 2. With unit plugged in and control power switch in the “ON” position verify LED status.

LED status

LED status

None, Control LED not

Short flash, once every

on or flashing.

four seconds.

 

 

 

 

 

 

 

 

 

Waiting for

 

 

call for heat.

 

 

29

Disconnect cord set as

 

 

shown in photo 29

 

 

Using a volt meter set

 

 

 

to volts AC, is there

N

 

 

120VAC across

 

 

 

 

 

terminals shown in

 

 

 

photo 30 ?

 

 

 

 

Y

 

 

 

 

 

 

 

Is there 120VAC

Y

Reconnect cord set

across terminals

 

shown in photo 29.

shown in photo 31 ?

 

 

 

 

 

N

 

 

 

 

 

 

 

 

Disconnect wire harness

 

 

 

Incorrect supply

 

 

from gas control

voltage polarity

 

(see photo 32).

Locate black & white wires at

connector, It may be necessary to pull back wire sheath to identify wire colors.

(see photo 33)

Is there 120VAC

 

across black & white Y

Replace gas

wires as shown in

 

control.

photo 33?

 

 

N

 

 

 

 

 

 

Call for technical

 

support.

 

LED status

LED status

“Heartbeat”, alternates

Various flashing error

bright/dim.

codes.

 

 

 

 

 

 

 

Thermostat calling

Verify error code as

for heat

listed on page 12

30

31

Check for damage to Y

Repair damage

AC supply power cord.

 

 

 

N

 

 

 

Replace Blower

 

32

Wire harness

33

Wire sheath pulled back to

identify wire colors

Check for 120VAC between black & white wires.

-NOTE-

Electronic meter probes required. Use care not to

damage connector during this check.

Page 31

31

Image 31
Contents Denotes Warranty Years Service ManualTable of Contents PDX Series Introduction How to Use This Manual Tools Required for ServiceSpecifications PDX Series Control Timings Sequence of Operation Power up SequenceAbnormal Operation Pressure Switch/Blower Temperature Fault LED Status TroubleshootingProbable Cause Service Status Procedure Green LED IndicatorTroubleshooting LED Status Cast Iron Burner Air Shutter Adjustment Burner Inspection and Air Shutter AdjustmentAir Shutter Nut Burner Surface area Feedline nut Pilot tubing nut Port area Burner CleaningOrifice Pilot Inspection, Testing and ReplacementIgniter/flame Sense wire Feedline nut Pilot tubing nut FerruleVolt potential exposure. Use caution Exhaust Pressure Switch TestingMaking voltage checks to avoid personal injury To avoid personal injury Exhaust Pressure Switch ReplacementSlide pressure switch in direction From blower housingSee Inlet Pressure SwitchSwitch for blockage Is there blockage? To call for heat, this will start the blowerRemove screws Inlet Pressure Switch ReplacementVolt potential exposure. Use caution when Blower TestingBlower Cord Sets Blower Mounting Screws Blower InstallationBlower removal Remove exhaustBlower Temperature Switch Testing Blower Temperature Switch Replacement Thermal Well Testing Gas Control TestingIf Control has gone into TCO lockout due to Sensor Resistance at Various Temperatures Determine Water Temperature Inside TankGas Control Removal From Thermal Well Gas Control & Thermal Well Removal From Water HeaterGas Control Assembly to Thermal Well Flammable Vapor Device Testing Safety Circuit Voltage Trace Across black & white Y Wires as shown ControlVAC Circuit Trace Shown in photoDip Tube Inspection and Replacement Anode Inspection and Replacement Flue baffle Inner Door Removal Procedure Installation of Inner Door With Gasket Installation of inner door with gasket from Glossary of Terms Parts List Parts@bradfordwhite.com Techserv@bradfordwhite.com