A.O. Smith COF-199 manual Features and Specifications, Tank Approx, Capacity EFF

Page 2

FEATURES AND SPECIFICATIONS

TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY. PLEASE READ THOROUGHLY BEFORE USING APPLIANCE.

This is a typical Duraclad oil-fired heater for commercial water heating

applications. The principal components of the heater are shown and

identified here. The identification plate illustrations on page 4 interpret

certain markings into useful information. Use these references to identify

the heater and its components

FIGURE 1

TABLE 1 NOMINAL MODEL DIMENSIONS

 

 

Model

 

 

COF - 199

 

COF - 245

 

COF - 315/315A

 

COF - 385/385A

 

COF - 455/455A

 

COF - 700/700A

 

 

 

 

Dim.

 

Inches

mm

 

Inches

mm

 

Inches

 

mm

 

 

Inches

 

 

mm

 

Inches

 

 

mm

 

Inches

 

 

mm

 

 

 

 

 

A

 

74 1/2

1,892

 

74 1/2

1,892

 

74 1/2

 

1,892

 

73 3/4

 

 

1,873

 

73 3/4

 

1,873

 

73 3/4

 

1,873

 

 

 

 

B

 

36 3/4

933

 

36 3/4

933

 

 

36 3/4

 

933

 

36 3/4

 

 

933

 

36 3/4

 

 

933

 

36 3/4

 

933

 

 

 

 

 

C

 

27 3/4

705

 

27 3/4

705

 

 

27 3/4

 

705

 

27 3/4

 

 

705

 

27 3/4

 

 

705

 

27 3/4

 

705

 

 

 

 

 

D

 

2

51

 

2

51

 

 

 

2

 

 

51

 

2

 

 

51

 

 

2

 

 

51

 

2

 

51

 

 

 

 

 

 

E

 

 

3/4 NPT

 

3/4 NPT

 

 

 

3/4 NPT

 

 

3/4 NPT

 

 

 

3/4 NPT

 

3/4 NPT

 

 

 

 

 

F

 

8

203

 

8

203

 

 

 

8

 

 

203

 

8

 

 

203

 

 

8

 

 

203

 

10

 

254

 

 

 

 

 

G

 

26 5/8

676

 

26 5/8

676

 

 

26 5/8

 

676

 

24 3/4

 

 

629

 

24 3/4

 

 

629

 

30 3/16

 

767

 

 

 

 

 

H

 

74 1/2

1,892

 

74 1/2

1,892

 

74 1/2

 

1,892

 

73 3/4

 

 

1,873

 

73 3/4

 

1,873

 

79 3/16

 

2,011

 

 

 

 

J

 

1 1/2 NPT

 

1 1/2 NPT

 

 

1 1/2 NPT

 

 

1 1/2 NPT

 

 

1 1/2 NPT

 

1 1/2 NPT

 

 

 

 

 

K

 

1 1/2 NPT

 

1 1/2 NPT

 

 

1 1/2 NPT

 

 

1 1/2 NPT

 

 

1 1/2 NPT

 

1 1/2 NPT

 

 

 

 

 

L

 

22 3/4

578

 

22 3/4

578

 

 

22 3/4

 

578

 

23 7/16

 

595

 

23 7/16

 

 

595

 

28 7/8

 

733

 

 

 

 

Approx.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping

 

553

251

 

554

252

 

 

554

 

252

 

624

 

 

283

 

700

 

 

318

 

739

 

335

 

 

 

Weight STD.

 

Lbs

Kg.

 

Lbs.

Kg.

 

Lbs.

 

Kg.

 

 

Lbs.

 

 

Kg.

 

Lbs.

 

 

Kg.

 

Lbs.

 

 

Kg.

 

 

 

 

Approx.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping

 

 

 

 

 

 

 

 

 

 

657

 

298

 

742

 

 

337

 

747

 

 

339

 

822

 

373

 

 

 

Weight ASME

 

---

---

 

---

---

 

 

Lbs.

 

Kg.

 

 

Lbs.

 

 

Kg.

 

Lbs.

 

 

Kg.

 

Lbs.

 

 

Kg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL DIMENSIONS IN INCHES/mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Model numbers followed by the suffix "A" indicates the optional A.S.M.E. tank construction.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 2 RECOVERY CAPACITIES, based on 80% efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK

APPROX

 

 

 

 

 

 

 

 

 

 

 

U.S Gallons/Hr. and Litres/Hr at TEMPERATURE RISE INDICATED

Model

 

 

 

 

CAPACITY

EFF.

 

 

40F°

 

50F°

 

60F°

 

70F°

 

 

 

80F°

 

90F°

 

100F°

 

110F°

120F°

130F°

 

140F°

 

Btuh

 

KW

U.S.Gal.

Litres

%

 

22.2C°

 

27.7C°

33.3C°

 

38.8C°

 

44.4C°

 

50C°

 

55.5C°

 

61.1C°

66.6C°

72.2C°

 

77.7C°

COF

 

199,000

 

 

86

 

 

 

80

GPH

 

477

 

381

 

 

318

 

 

272

 

238

212

 

191

 

 

173

 

159

147

 

136

199

 

 

58

 

 

326

 

 

LPH

 

1804

 

1443

 

1203

 

 

1031

 

902

802

 

722

 

 

656

 

601

555

 

516

COF

 

245,000

 

 

86

 

 

 

80

GPH

 

587

 

469

 

 

391

 

 

335

 

293

261

 

235

 

 

213

 

196

181

 

168

245

 

 

72

 

 

326

 

 

LPH

 

2221

 

1777

 

1481

 

 

1269

 

1111

987

 

889

 

 

808

 

740

683

 

635

COF

 

315,000

 

 

84

 

 

 

80

GPH

 

754

 

604

 

 

503

 

 

431

 

377

335

 

302

 

 

274

 

251

232

 

216

315/315A

 

92

 

 

318

 

 

LPH

 

2856

 

2285

 

1904

 

1632

 

1428

1269

 

1142

 

1039

 

952

879

 

816

COF

 

385,000

 

 

75

 

 

 

80

GPH

 

922

 

738

 

 

615

 

 

527

 

461

410

 

369

 

 

335

 

307

284

 

263

385/385A

 

113

 

 

284

 

 

LPH

 

3491

 

2793

 

2327

 

 

1995

 

1745

1551

 

1396

 

1269

 

1164

1074

 

997

COF

 

455,000

 

 

75

 

 

 

80

GPH

 

1090

 

872

 

 

727

 

 

623

 

545

484

 

436

 

 

396

 

363

335

 

311

455/455A

 

133

 

 

284

 

 

LPH

 

4125

 

3300

 

2750

 

 

2357

 

2063

1833

 

1650

 

1500

 

1375

1269

 

1179

COF

 

700,000

 

 

69

 

 

 

80

GPH

 

1677

 

1341

 

1118

 

 

958

 

838

745

 

671

 

 

610

 

559

516

 

479

700/700A

 

205

 

 

261

 

 

LPH

 

6347

 

5077

 

4231

 

 

3627

 

3173

2821

 

2539

 

2308

 

2116

1953

 

1813

*All tanks are tested at 320 psig working pressure.

**Based on No. 2 fuel oil with a heat content of 140,000 Btu's per gallon at 80% thermal efficiency. Above 2,000 altitude, input ratings should be reduced 4% for each 1000' above sea level.

2

Image 2
Contents Place These Instructions Adjacent to Heater Notify Owner to Keep for Future ReferenceCapacity EFF Features and SpecificationsTank Approx Table of Contents ApprovalsSafety InstallationCombustion and Ventilation AIR Proper Installation on Combustible FlooringClearances Chemical Vapor CorrosionVent Connector and Draft Regulator Flue GAS VentingFuel Systems Water PipingClosed Water System Gravity FEED, Supply Line ONLY, Installation Burner InstallationTypical Heater Installation Figure System TypesFuel Pump OIL Pump & Nozzle SpecificationsAssembly of the OIL Burner to the Heater BurnerSTART-UP OperationFilling SELF-CLEANING Eliminator Water Temperature ControlHigh Limit Switch E.C.O Burner Certificate Combustion TestMaintenance Flo-jug Method of Deliming Deliming the COF Water HeaterVent System Circulating PumpSoot Removal Typical Heater Flueway and Flue BaffleInset B Installation DiagramsInstall in Accordance with Local Codes Inset aSingle Temperature or Booster Pipe to Open DrainInset B Install in Accordance with Local Codes Inset a Not Enough or no HOT Water Check List and Service InformationElectrical Wiring Replacement Water Heater Makes Sounds Burner STARTS-WONT OperateWater is TOO HOT Water Leakage is SuspectedSafety Primary Control Combustion Test SpecificationsNormal START, but Locks OUT on Safety ProcedureTrouble Cause Remedy TroubleshootingOIL Burner Troubleshooting Tank Service and Repair ExpensesClaim Procedure ALL Other PartsCommercial Water Heater Parts List Smith Water Products CO., INCLabels Cleanout Assembly+WIRE Page Page Asme Impriméaux É.-UPoids approx Lexpédition Dimensions COFCaractéristiques ET Données Techniques StandardIdentification Table DES MatièresHomologations COF 455 940 CO5MOO6721Installation SécuritéAIR DE Combustion ET DE Ventilation Installation Correcte SUR UN Plancher CombustibleDégagement À Prévoir Corrosion DUE AUX Vapeurs ChimiquesÉvacuation DES GAZ DE Combustion Tableau 4 Dimensions Suggérées Pour LES Raccords D’ÉVENTInstallation Appropriée DU Raccord D’ÉVENT Cheminée Raccord D’ÉVENT ET Régulateur DE TirageRobinet DE Vidange ET Panneaux D’ACCÈS Tuyauterie D’EAUSystème EN Circuit Fermé Systèmes D’ALIMENTATION EN CombustibleTableau Installation DU BrûleurInstallation Type DE CHAUFFE-EAU Figure Types DE SystèmesMontage DU Brûleur SUR LE CHAUFFE-EAU Pompe À MazoutBrûleur Tableau 8 Caractéristiques DES Pompes ET DES Buses À MazoutMise EN Marche Initiale Mise EN Marche ET UtilisationRemplissage Certificat DU Brûleur Test DE Combustion Réglage DE LA Température DE L’EAULimiteur DE Température Système Autonettoyant EliminatorEntretien Méthode de détartrage Flo-Jug Détartrage DU CHAUFFE-EAU COFConduit DE Fumée ET Chicane D’UN CHAUFFE-EAU Type Pompe DE CirculationEnlèvement DE LA Suie Encadré B Schémas D’INSTALLATIONInstaller Conformément AUX Codes Locaux Encadré aSystème À UNE Seule Température OU Surchauffeur Encadré B Installer Conformément AUX Codes Locaux Encadré B Insuffisance OU Absence D’EAU Chaude Liste DE Contrôle ET Renseignements SUR LE ServiceRemplacement DU Câblage Électrique Ensemble DE Collecteur Pour Trois AppareilsBruits EN Provenance DU CHAUFFE-EAU LE Brûleur Démarre Mais NE Fonctionne PASEAU Trop Chaude Fuite D’EAU SoupçonnéeDémarrage Normal Suivi ’UN Verrouillage DE Sécurité Commande Primaire DE SécuritéSpécifications Pour LE Test DE Combustion Perte DE LA Flamme Après UN Allumage NormalTableau 10 Dépannage DU Brûleur À Mazout DépannageProblème Cause Mesure Corrective Modèles COF Garantie Limitée Autres PiècesSmith Water Products CO., INC COF Article Description