Brother BAS-311F-L, BAS-326F-0, BAS-311F-0 Adjusting the wiper, For vertical wiper standard

Page 55

9. STANDARD ADJUSTMENTS

9-9. Adjusting the wiper

<For vertical wiper (standard)>

(4)

(3)

 

 

 

(1)

 

 

 

 

 

(2)

 

 

 

 

 

 

 

(2)

(6)

(5)

 

 

approx. 2 mm

 

 

approx.

 

 

 

 

112 mm

15 mm

 

 

 

1257S

1258S

 

1259S

 

 

 

 

 

1.When the thread wiper solenoid plunger (1) is driven to the full stroke, the wiper (2) should be 15 mm in front of the needle center. Loosen screws (3) and shift the entire solenoid bracket (4)up or down to adjust.

The standard height from the solenoid bracket (4) bottom to the needle plate top is approximately 112 mm.

2.When the wiper (2) is operated and aligned with the center of the needle bar, the distance from the wiper (2) to needle tip should be approximately 2 mm. Loosen screw (5) and move the wiper (2) in or out to adjust. As shown in Fig. A,

make sure the wiper (2) does not strike the presser foot (6) or needle.

Note

Check that the wiper (2) is not touching the finger guard.

<For vertical wiper (standard)>

1261S

(3) (6)

(4)

(5)

15mm - 16mm

(1)

 

 

 

 

 

 

(2) 25 mm

25 mm 35 mm

35 mm

 

 

 

1260S

 

1262S

1263S

1.Loosen the set screw (2) and move the wiper arm support (3) up or down to adjust so that there is a clearance of 15 - 16 mm between the bottom of the thread wiper and the tip (1) of the needle when the thread wiper is aligned with the center of the needle bar.

2.After the thread wiper has wiped the thread, loosen the bolt (5) and move the whole solenoid fixing plate (6) up or down to adjust so that the distance is approximately 25 mm.

48

BAS-311F-0, 311F-L, 326F-0

Image 55
Contents BAS-326F-0 Safety indications and their meanings Safety InstructionsEnvironmental requirements InstallationSewing CleaningMaintenace and inspection Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts BAS-311F-L *3 a BAS-326F-0 *4 a SpecificationsInstallation Positioning Table processing diagramInstalling the control box Installing the oil pan Installing the rubber cushionsInstalling the switching plate Installing the cushionsInstalling the machine head Tilting the sewing machine head 1170S Connecting the cords Installing the operation panel Connecting the ground wireBAS-311F-0 Solenoid type only ORG Installing the foot switch Installing the belt coverInstalling the spool stand Installing the eye guard Installing the programmer option Installing the X feed base cover BAS-311F-L, 326F-0 Installing the feed base cover supports BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to a beam When installing to the underside of the work tableLubrication points LubricationBAS-326F-0 Correct Operation Installing the needleSelecting the needle and thread Threading the upper thread Winding the lower thread Sewing conditions and thread tension Replacing the bobbin case and threading the threadLower thread tension Explanation of panel Using the Operation Panel110 Compatible types of floppy disk Using the floppy diskHow to use the cleaning disk Setting the floppy diskTo Read a pattern to memory Using the program R/W Read/Write switchIf an error message is displayed Clearing the errorResuming operation from a stopping poing Using the Test switch Checking the sewing patternContinuing sewing from a stopping point Using the emergency stop switchChanging the X-SCALE and Y-SCALE settings Adjusting the sewing Speed controlUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Before starting sewing SewingSewing operation 1230S Draining the oil Cleaning and InspectionCleaning the rotary hook LubricationChecking the needle Cleaning the control box air inlet portCleaning the air holes of belt cover and frame side cover Cleaning the eye guardAdjusting the needle bar height Standard AdjustmentsAdjusting the needle bar lift amount Adjusting the driver needle guard Adjusting the needle clearanceAdjusting the shuttle race thread guide Adjusting the movable knife Abcd Replacing the movable and fixed knivesAdjusting the presser foot Standard presser foot lift is 3 mm max mm Adjusting presser foot lift to 3 5mmAdjusting presser foot lift to 5 8 mm Changing the presser foot liftFor vertical wiper standard Adjusting the wiperBAS-311F-0 Solenoid type Adjusting the two-step work clamp lift amountBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Checking the input voltage Clearing all memory settingsPanel DIP switch functions DIP SwitchBAS-311F-L only DipswitchDIP Switch C DIP switches inside the control boxDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection WP stitch device Automatic bobbin changer OptionsPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone