Brother BAS-326F-0, BAS-311F-L Checking the input voltage, Clearing all memory settings

Page 60

9. STANDARD ADJUSTMENTS

9-13. Checking the input voltage

1.Turn on the power switch.

2.Press the menu switch (1) until the X-SCALE indicator (2) illuminates.

1275S

(1)

(2)

1276S

 

3. While pressing the TEST switch (3), press the R/W switch (4)

 

(3)

 

 

(4)

 

 

 

1277S

 

 

1278S

4. If the input voltage is normal, the input voltage conditions will be shown in the display as indicated at right.

200-V specifications

090 - 110

"100" is displayed when the input voltage is 200 V.

 

 

200-V specifications

100 - 120

 

 

 

 

200-V specifications

105 - 125

"110" is displayed when the input voltage is 100 V (for

 

 

100-V specs.), 380 V (for 380-V specs.).

100-V, 380-V, 400-V

100 - 120

 

5. Press the TEST switch (3) once more to return the display to the normal condition.

9-14. Clearing all memory settings

If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been made by means of the memory switch, for instance. In such cases, carry out the following procedure to clear the memory, and also check the DIP switch settings.

While pressing the R/W switch (1), turn on the power. This will clear all of the memory setting.

Note

This operation causes memory switch settings to be returned to their initial settings, and also clears all contents of the memory such as sewing datas.

(1)

1279S

1278S

BAS-311F-0, 311F-L, 326F-0

53

Image 60
Contents BAS-326F-0 Safety Instructions Safety indications and their meaningsInstallation Environmental requirementsCleaning SewingMaintenace and inspection Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts Specifications BAS-311F-L *3 a BAS-326F-0 *4 aInstallation Table processing diagram PositioningInstalling the control box Installing the rubber cushions Installing the oil panInstalling the cushions Installing the switching plateInstalling the machine head Tilting the sewing machine head 1170S Connecting the ground wire Connecting the cords Installing the operation panelBAS-311F-0 Solenoid type only ORG Installing the belt cover Installing the foot switchInstalling the spool stand Installing the eye guard Installing the programmer option Installing the feed base cover supports BAS-311F-L, 326F-0 Installing the X feed base cover BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to the underside of the work table When installing to a beamLubrication Lubrication pointsBAS-326F-0 Installing the needle Correct OperationSelecting the needle and thread Threading the upper thread Winding the lower thread Replacing the bobbin case and threading the thread Sewing conditions and thread tensionLower thread tension Using the Operation Panel Explanation of panel110 Using the floppy disk Compatible types of floppy diskSetting the floppy disk How to use the cleaning diskUsing the program R/W Read/Write switch If an error message is displayedClearing the error To Read a pattern to memoryUsing the Test switch Checking the sewing pattern Resuming operation from a stopping poingUsing the emergency stop switch Continuing sewing from a stopping pointAdjusting the sewing Speed control Changing the X-SCALE and Y-SCALE settingsUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Sewing Before starting sewingSewing operation 1230S Cleaning and Inspection Cleaning the rotary hookLubrication Draining the oilCleaning the control box air inlet port Cleaning the air holes of belt cover and frame side coverCleaning the eye guard Checking the needleStandard Adjustments Adjusting the needle bar heightAdjusting the needle bar lift amount Adjusting the needle clearance Adjusting the driver needle guardAdjusting the shuttle race thread guide Adjusting the movable knife Replacing the movable and fixed knives AbcdAdjusting the presser foot Adjusting presser foot lift to 3 5mm Adjusting presser foot lift to 5 8 mmChanging the presser foot lift Standard presser foot lift is 3 mm max mmAdjusting the wiper For vertical wiper standardAdjusting the two-step work clamp lift amount BAS-311F-0 Solenoid typeBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Clearing all memory settings Checking the input voltageDIP Switch Panel DIP switch functionsDipswitch BAS-311F-L onlyDIP switches inside the control box DIP Switch CDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection Options WP stitch device Automatic bobbin changerPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone