10.DIPSWITCH

DIP switch A

SW No.

When ON

A-5

After sewing is completed, work clamp does not automatically rise (only in split mode)

 

 

A-6

Clamping force output is produced (Inner clamping device available as an option)

ASingle-pedal operation using the starting switch; when the starting switch is pressed, the work clamp

-7

drops, and when it is released, sewing starts.

A-8

Thread breakage detector device is activated (available as an option)

DIP switch B

SW No.

When ON

B-1

Single split mode activated

 

 

B-2

BAS-311F-L: The sewing area in the X direction is extended to 230 mm from 220 mm.*

 

 

B-3

Needle cooler output is produced.

 

 

B-4

Thread is not trimmed after an emergency stop.

 

 

B-5

When a rotating-type thread breakage detector device is used, detection precision is increased from 8 to 14.

When a fiber-type thread breakage detector device is used, detection precision is increased from 5 to 10.

 

 

 

B-6

Fiber-type thread breakage detector device is ON, and DIP switch A - 8 is ON (available as an option)

 

 

B-7

When using a 3-stage pedal

If DIP switch A -2 is ON at the same time, the presser foot will drop at the same time that both work clamps

 

drop.

B-8

Feeding speed is switched to high speed.

* <BAS-311F-L only>

If using the work clamp and sewing data for the older BAS-311EL model, set DIP switch B -2 ON. The BAS-311 L-type has a defferent length for the sewing area in the X derection (X=220 mm).

Old BAS-311EL X -100 mm

+120 mm

New BAS-311F-L X -110 mm

+110 mm

Note

The break of the sewing pattern is apt to occur in the extended sewing area.

BAS-311F-0, 311F-L, 326F-0

55

Image 62
Contents BAS-326F-0 Safety Instructions Safety indications and their meaningsInstallation Environmental requirementsMaintenace and inspection CleaningSewing Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts Specifications BAS-311F-L *3 a BAS-326F-0 *4 aInstallation Table processing diagram PositioningInstalling the control box Installing the rubber cushions Installing the oil panInstalling the cushions Installing the switching plateInstalling the machine head Tilting the sewing machine head 1170S Connecting the ground wire Connecting the cords Installing the operation panelBAS-311F-0 Solenoid type only ORG Installing the spool stand Installing the belt coverInstalling the foot switch Installing the eye guard Installing the programmer option Installing the feed base cover supports BAS-311F-L, 326F-0 Installing the X feed base cover BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to the underside of the work table When installing to a beamBAS-326F-0 LubricationLubrication points Selecting the needle and thread Installing the needleCorrect Operation Threading the upper thread Winding the lower thread Replacing the bobbin case and threading the thread Sewing conditions and thread tensionLower thread tension Using the Operation Panel Explanation of panel110 Using the floppy disk Compatible types of floppy diskSetting the floppy disk How to use the cleaning diskClearing the error Using the program R/W Read/Write switchIf an error message is displayed To Read a pattern to memoryUsing the Test switch Checking the sewing pattern Resuming operation from a stopping poingUsing the emergency stop switch Continuing sewing from a stopping pointAdjusting the sewing Speed control Changing the X-SCALE and Y-SCALE settingsUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Sewing operation SewingBefore starting sewing 1230S Lubrication Cleaning and InspectionCleaning the rotary hook Draining the oilCleaning the eye guard Cleaning the control box air inlet portCleaning the air holes of belt cover and frame side cover Checking the needleAdjusting the needle bar lift amount Standard AdjustmentsAdjusting the needle bar height Adjusting the shuttle race thread guide Adjusting the needle clearanceAdjusting the driver needle guard Adjusting the movable knife Replacing the movable and fixed knives AbcdAdjusting the presser foot Changing the presser foot lift Adjusting presser foot lift to 3 5mmAdjusting presser foot lift to 5 8 mm Standard presser foot lift is 3 mm max mmAdjusting the wiper For vertical wiper standardAdjusting the two-step work clamp lift amount BAS-311F-0 Solenoid typeBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Clearing all memory settings Checking the input voltageDIP Switch Panel DIP switch functionsDipswitch BAS-311F-L onlyDIP switches inside the control box DIP Switch CDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection Options WP stitch device Automatic bobbin changerPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone