Brother BAS-326F-0 Changing the presser foot lift, Standard presser foot lift is 3 mm max mm

Page 54

9. STANDARD ADJUSTMENTS

9-8. Changing the presser foot lift

<Standard presser foot lift is 3 mm (max. 8 mm). >

(3)

(9)

3 - 5 mm

(8)

 

 

 

 

(6)

(4)

(5)

(2)

(7)

0.5 - 1 mm

 

1252S

 

1253S

 

1254S

Adjusting presser foot lift to 3 - 5mm

1.Loosen the screw (2) and open the intermittent cover (3).

2.Loosen the nut (4) and adjust the intermittent presser connecting rod (5) position.

(When the intermittent presser connecting rod is raised, the lift will increase. When lowered, the lift will decrese.)

Adjusting presser foot lift to 5 - 8 mm

1.Turn the upper shaft to set the presser foot to its lowest point. Loosen the screw (9) of intermittent presser arm (R) (8). Adjust the clearance between the presser lifter (6) and the presser bar bush (7) to 0.5 - 1 mm.

2.Loosen the nut (4) and adjust the intermittent presser connecting rod (5) position.

(When the intermittent presser connecting rod is raised, the lift will increase. When lowered, the lift will decrese.)

(14)

(13)

(11)

(12)

(10)

1255S

1256S

If vertical movement of the presser foot is not required

1.Remove the face plate (10).

2.Remove the stud screw (11) and re-attach the intermitte connecting rod (12) to the upper screw hole (14) of the intermittent presser arm F (13).

BAS-311F-0, 311F-L, 326F-0

47

Image 54
Contents BAS-326F-0 Safety Instructions Safety indications and their meaningsInstallation Environmental requirementsCleaning SewingMaintenace and inspection Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts Specifications BAS-311F-L *3 a BAS-326F-0 *4 aInstallation Table processing diagram PositioningInstalling the control box Installing the rubber cushions Installing the oil panInstalling the cushions Installing the switching plateInstalling the machine head Tilting the sewing machine head 1170S Connecting the ground wire Connecting the cords Installing the operation panelBAS-311F-0 Solenoid type only ORG Installing the belt cover Installing the foot switchInstalling the spool stand Installing the eye guard Installing the programmer option Installing the feed base cover supports BAS-311F-L, 326F-0 Installing the X feed base cover BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to the underside of the work table When installing to a beamLubrication Lubrication pointsBAS-326F-0 Installing the needle Correct OperationSelecting the needle and thread Threading the upper thread Winding the lower thread Replacing the bobbin case and threading the thread Sewing conditions and thread tensionLower thread tension Using the Operation Panel Explanation of panel110 Using the floppy disk Compatible types of floppy diskSetting the floppy disk How to use the cleaning diskClearing the error Using the program R/W Read/Write switchIf an error message is displayed To Read a pattern to memoryUsing the Test switch Checking the sewing pattern Resuming operation from a stopping poingUsing the emergency stop switch Continuing sewing from a stopping pointAdjusting the sewing Speed control Changing the X-SCALE and Y-SCALE settingsUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Sewing Before starting sewingSewing operation 1230S Lubrication Cleaning and InspectionCleaning the rotary hook Draining the oilCleaning the eye guard Cleaning the control box air inlet portCleaning the air holes of belt cover and frame side cover Checking the needleStandard Adjustments Adjusting the needle bar heightAdjusting the needle bar lift amount Adjusting the needle clearance Adjusting the driver needle guardAdjusting the shuttle race thread guide Adjusting the movable knife Replacing the movable and fixed knives AbcdAdjusting the presser foot Changing the presser foot lift Adjusting presser foot lift to 3 5mmAdjusting presser foot lift to 5 8 mm Standard presser foot lift is 3 mm max mmAdjusting the wiper For vertical wiper standardAdjusting the two-step work clamp lift amount BAS-311F-0 Solenoid typeBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Clearing all memory settings Checking the input voltageDIP Switch Panel DIP switch functionsDipswitch BAS-311F-L onlyDIP switches inside the control box DIP Switch CDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection Options WP stitch device Automatic bobbin changerPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone