9. STANDARD ADJUSTMENTS

9-11. Adjusting the needle up stop position

(3)

 

 

(4)

 

 

 

 

(1)

(2)

 

(5)

(6)

(7)

 

1272S

The needle up stop position is adjusted so that the index mark (2) on the machine pulley (1) is inside the mark (4) on the belt cover (3).

If adjustment is necessary, loosen the screw (5) at the "U" mark of the machine pulley (1) and adjust the position of the machine pulley (1). The machine pulley (1) stops later if it is turned clockwise, and it stops earlier if it is turned counterclockwise.

Note

The screw (6) is used by the needle down detection function and should not be loosened.

The screw (7) is a screw for detecting the machine stop position, and should not be loosened.

If the index mark (2) is not inside the mark (4) when be displayed (when memory switch No.14 is on). Turn the machine pulley to move the index mark

(2)to the correct position and then start the sewing machine.

BAS-311F-0, 311F-L, 326F-0

51

Image 58
Contents BAS-326F-0 Safety Instructions Safety indications and their meaningsInstallation Environmental requirementsSewing CleaningMaintenace and inspection Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts Specifications BAS-311F-L *3 a BAS-326F-0 *4 aInstallation Table processing diagram PositioningInstalling the control box Installing the rubber cushions Installing the oil panInstalling the cushions Installing the switching plateInstalling the machine head Tilting the sewing machine head 1170S Connecting the ground wire Connecting the cords Installing the operation panelBAS-311F-0 Solenoid type only ORG Installing the foot switch Installing the belt coverInstalling the spool stand Installing the eye guard Installing the programmer option Installing the feed base cover supports BAS-311F-L, 326F-0 Installing the X feed base cover BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to the underside of the work table When installing to a beamLubrication points LubricationBAS-326F-0 Correct Operation Installing the needleSelecting the needle and thread Threading the upper thread Winding the lower thread Replacing the bobbin case and threading the thread Sewing conditions and thread tensionLower thread tension Using the Operation Panel Explanation of panel110 Using the floppy disk Compatible types of floppy diskSetting the floppy disk How to use the cleaning diskClearing the error Using the program R/W Read/Write switchIf an error message is displayed To Read a pattern to memoryUsing the Test switch Checking the sewing pattern Resuming operation from a stopping poingUsing the emergency stop switch Continuing sewing from a stopping pointAdjusting the sewing Speed control Changing the X-SCALE and Y-SCALE settingsUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Before starting sewing SewingSewing operation 1230S Lubrication Cleaning and InspectionCleaning the rotary hook Draining the oilCleaning the eye guard Cleaning the control box air inlet portCleaning the air holes of belt cover and frame side cover Checking the needleAdjusting the needle bar height Standard AdjustmentsAdjusting the needle bar lift amount Adjusting the driver needle guard Adjusting the needle clearanceAdjusting the shuttle race thread guide Adjusting the movable knife Replacing the movable and fixed knives AbcdAdjusting the presser foot Changing the presser foot lift Adjusting presser foot lift to 3 5mmAdjusting presser foot lift to 5 8 mm Standard presser foot lift is 3 mm max mmAdjusting the wiper For vertical wiper standardAdjusting the two-step work clamp lift amount BAS-311F-0 Solenoid typeBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Clearing all memory settings Checking the input voltageDIP Switch Panel DIP switch functionsDipswitch BAS-311F-L onlyDIP switches inside the control box DIP Switch CDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection Options WP stitch device Automatic bobbin changerPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone