9. STANDARD ADJUSTMENTS
9-10. Adjusting the two-step work clamp lift amount
The maximum work clamp lift amount is 25 1 mm (for solenoid type) or 30 1 mm (for pneumatic type) from the top of the needle plate.
The lift amount for each model is adjusted as shown in the table at the time of shipment.
type | Solenoid type | Pneumatic type |
| ||
|
| |
|
|
|
Lift amount | 20 mm | |
|
|
|
9-10-1. BAS-311F-0 Solenoid type
(3)
(2)
(1)
20 mm
1264S
1.Turn the power switch OFF.
2.Loosen the bolts (2) of work clamp arm lever F (1) .
3.Plase a scale against the work clamp (3), and then move work clamp arm lever F (1) up or down to adjust so that the amount of lift above the top of the needle plate is 20 mm.
4.After adjusting the lift amount (20 mm), tighten the bolts of work clamp arm lever F (1) .
9-10-2. BAS-311F-0, 311F-L Pneumatic type
(3) | (3) |
(2) | (2) |
| |
(4) | (4) |
(1)
20 mm
scale
1265S | 1266S | 1267S |
|
1.Turn on the air, and then press the work clamp lifter switch (1) to raise the work clamp (2) .
2.Loosen the bolts (4) of work clamp arm lever F (3) .
3.Place a scale against the work clamp (2), and then move work clamp arm lever F (3) up and down to adjust so that the lift amount is 20 mm.
4.After adjusting the lift amount (20 mm), tighten the bolts (4) of work clamp arm lever F (3).
49