Brother BAS-311F-L, BAS-326F-0, BAS-311F-0 instruction manual Switch No When on Memo-10

Page 67

11.CHANGING SPECIAL FUNCTION AND USING THE MEMORY SWITCHES Memory switches (10 - 1F)

Switch No.

 

When ON

 

 

 

 

 

 

 

 

 

 

 

memo-10

Milling device can be used (available as an option)

 

 

 

 

 

 

 

 

 

memo-11

Bobbin thread counter and production counter are adjusted when thread is trimmed.

 

 

 

 

 

Work clamp is lowered by pressing work clamp first stage switch twice, without using work clamp

memo-12

second stage switch. When DIP switch A-2 is ON, work clamp lowers in the order right

left;

 

when OFF, work clamp lowers in the order left

right. Order is opposite when rising.

 

 

 

When work clamp is lowered, the starting switch causes locking; if the switch is released before

memo-13

locking, the work clamp rises

 

 

 

 

 

When DIP switch A - 2 is ON, work clamp lowers in the order right

left; when OFF, work clamp

 

 

lowers in the order left

right. Order is opposite when rising

 

 

 

memo-14

Needle up error detected.

 

 

 

 

 

 

 

 

memo-15

ON when machine is equipped with signal tower indicator. (This indicator is available by special

order.)

 

 

 

 

 

 

 

 

 

 

 

 

 

memo-16

ON when machine is equipped with thread nipper. (Thread nipper is available by special order.)

 

 

 

 

memo-17

ON when machine is equipped with reset switch. (Reset switch is available by special order.)

 

 

 

 

 

 

Starting switch causes work clamp to drop in order right

left

forward control is in the same

memo-18

order as starting, and for backward control the work clamp rises in the order left

right using

work clamp first stage switch (when DIP switch A-2 is ON). When OFF, the left and right orders are

 

 

reversed.

 

 

 

 

 

 

memo-19

Produces two work clamp signal outputs (right and left work clamp) so that a two-position air valve

can be used. (Two-position air valve is available by special order.)

 

 

 

 

 

 

 

 

When using a triple pedal (DIP switch B-7 is also ON), the right is used exclusively to detect the

memo-1A

home position. If DIP switch A-7 is OFF, the left pedal causes left and right work clamps to be raised

and lowered simultaneously. If ON, the left pedal causes the left work clamp to be raised and

 

 

lowered, and the right work clamp lowers when starting pedal to sew.

 

 

 

memo-1b

KE430B single foot pedal can be used. DIP switch A-7 is ON.

 

 

 

 

 

 

 

 

 

memo-1c

Bobbin thread counter is decremented at the start of sewing.

 

 

 

 

 

 

memo-1d

When using an air pressure drop detection switch. (This detection switch is available by special

order.)

 

 

 

 

 

 

 

 

 

 

 

 

 

memo-1E

Changes the split number automatically by using an external switch. (Use option connector P3 on

the operation panel.)

 

 

 

 

 

 

 

 

 

 

 

 

 

memo-1F

Program number is changed automatically by using outside switch. (Use optional connector P3 on

the operation panel.)

 

 

 

 

 

 

 

 

 

 

 

 

 

60

BAS-311F-0, 311F-L, 326F-0

Image 67
Contents BAS-326F-0 Safety indications and their meanings Safety InstructionsEnvironmental requirements InstallationSewing CleaningMaintenace and inspection Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts BAS-311F-L *3 a BAS-326F-0 *4 a SpecificationsInstallation Positioning Table processing diagramInstalling the control box Installing the oil pan Installing the rubber cushionsInstalling the switching plate Installing the cushionsInstalling the machine head Tilting the sewing machine head 1170S Connecting the cords Installing the operation panel Connecting the ground wireBAS-311F-0 Solenoid type only ORG Installing the foot switch Installing the belt coverInstalling the spool stand Installing the eye guard Installing the programmer option Installing the X feed base cover BAS-311F-L, 326F-0 Installing the feed base cover supports BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to a beam When installing to the underside of the work tableLubrication points LubricationBAS-326F-0 Correct Operation Installing the needleSelecting the needle and thread Threading the upper thread Winding the lower thread Sewing conditions and thread tension Replacing the bobbin case and threading the threadLower thread tension Explanation of panel Using the Operation Panel110 Compatible types of floppy disk Using the floppy diskHow to use the cleaning disk Setting the floppy diskTo Read a pattern to memory Using the program R/W Read/Write switchIf an error message is displayed Clearing the errorResuming operation from a stopping poing Using the Test switch Checking the sewing patternContinuing sewing from a stopping point Using the emergency stop switchChanging the X-SCALE and Y-SCALE settings Adjusting the sewing Speed controlUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Before starting sewing SewingSewing operation 1230S Draining the oil Cleaning and InspectionCleaning the rotary hook LubricationChecking the needle Cleaning the control box air inlet portCleaning the air holes of belt cover and frame side cover Cleaning the eye guardAdjusting the needle bar height Standard AdjustmentsAdjusting the needle bar lift amount Adjusting the driver needle guard Adjusting the needle clearanceAdjusting the shuttle race thread guide Adjusting the movable knife Abcd Replacing the movable and fixed knivesAdjusting the presser foot Standard presser foot lift is 3 mm max mm Adjusting presser foot lift to 3 5mmAdjusting presser foot lift to 5 8 mm Changing the presser foot liftFor vertical wiper standard Adjusting the wiperBAS-311F-0 Solenoid type Adjusting the two-step work clamp lift amountBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Checking the input voltage Clearing all memory settingsPanel DIP switch functions DIP SwitchBAS-311F-L only DipswitchDIP Switch C DIP switches inside the control boxDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection WP stitch device Automatic bobbin changer OptionsPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone