| 12. ERROR CODES |
|
|
| |
|
|
| |
|
|
| |
Code | Cause | Remedy | |
|
|
|
|
E.A0 | Start switch was pressed when there was no | Read sewing data again. |
|
| sewing available data. |
|
|
E.A1 | Can not detect home position. | Turn off power and, check | |
| connection of home position sensor is incorrect. |
|
|
|
|
|
|
E.c0 | Motor PROM is not correctly inserted. | Turn off power and check it. |
|
E.c1 | Cooling fan (left one when viewed from front) in | Turn off power and check it. | Check fan connector. |
| control box does not operate. |
|
|
E.c2 | Turn off power and clean air inlet port. | ||
E.c3 | Overcurrent was detected in X pulse motor. | Turn off power and check it. |
|
E.c4 | Overcurrent was detected in Y pulse motor. | Turn off power and check it. |
|
E.c5 | Cooling fan (right one when viewed from front) in | Turn off power and check it. | Check fan connector. |
| control box does not operate. |
|
|
|
|
| |
E.d0 | Air pressure has dropped. | If not use detector, set OFF memory switch 1d. | |
|
|
|
|
E.E0 | Control PROM is not correctly inserted. | Turn off power and check it. |
|
E.E1 | Main PCB detected communication error. | Turn off power and then on again. | |
E.E2 | Panel PCB detected communication error. | Turn off power and then on again. | |
E.E3 | Incorrect connection of cable between operation | Turn off power and check it. |
|
| panel and control box. |
|
|
|
|
|
|
E.F0 | Solenoid is | Turn off power and check it. |
|
| circuit board) or power supply relay is not operating |
|
|
| (malfunction of power supply circuit board). |
|
|
E.F1 | Incorrect connection of cable between power supply | Turn off power and check connector P20. | |
| PCB and main PCB. |
|
|
E.F2 | Over current at power supply PCB. | Turn off power and check it. |
|
|
|
|
|
REFERENCE segment LED alphabet
Panel display
Text display |
| A |
| B |
| C |
| D |
| E |
| F |
| 6 |
| H |
| L |
| O |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
65