12. ERROR CODES
Code | Cause |
|
|
| Remedy |
|
|
|
|
|
|
| |||||||
E.40 | Floppy disk is not inserted or operation panel cable | Insert a floppy disk. If floppy disk is already inserted, | |||||||
| is not securely connected. | turn off the power and check the connections of cords | |||||||
|
| inside the operation panel. |
|
|
|
| |||
E.41 | Invalid program No., or no data. | Change program No.. |
|
|
|
|
| ||
E.43 | Different floppy disk! | Use original floppy disk. |
|
|
|
| |||
|
|
|
| ||||||
E.4F | Error occurred during floppy disk data reading. | Replace the floppy disk and repeat the operation. | |||||||
|
|
|
|
|
|
| |||
E.50 | Floppy disk is | Release |
|
|
|
| |||
E.51 | Insufficient available memory on floppy disk. | Use another floppy disk. |
|
|
|
| |||
E.52 | Can not format this floppy disk. | Change floppy disk. |
|
|
|
|
| ||
E.5F | Error occurred during data writing on floppy disk. | Replace the floppy disk and repeat the operation. | |||||||
|
|
| |||||||
E.60 | Can not backup data. (Panel PCB) | Turn off power and then clear all of the memory setting. | |||||||
E.61 | Can not backup data. (Control PCB) | Turn off power and then clear all of the memory setting. | |||||||
E.62 | Operation panel error. | Turn off power and then on again. |
|
|
| ||||
E.63 | Combination of control PROM and operation panel | Turn off power and check it |
|
|
|
| |||
| PROM is invalid. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
E.70 | Same optional output number already exists. | Change optional output number. |
|
|
|
| |||
|
| If not use optional output, turn off power and then clear | |||||||
|
| all of the memory setting. |
|
|
|
| |||
E.71 | Bobbin changer error! | See the manual for bobbin changer. |
|
|
| ||||
- |
| If not using the bobbin changer, set memory switch 23 | |||||||
E.74 |
| to OFF. |
|
|
|
|
|
|
|
E.75 | Milling motor has stopped due to overload. | See the manual for Milling motor. |
|
|
| ||||
|
| If not use milling motor, set OFF memory switch 10. | |||||||
|
|
|
|
|
|
|
|
|
|
E.80 | Upper thread has broken. (Rotary type sensor) | Thread | upper | thread | again. | You | can | start | sewing |
|
| again. |
|
|
|
|
|
|
|
E.81 | Upper thread has broken. (Optical fiber type sensor) | Thread | upper | thread | again. | You | can | start | sewing |
|
| again. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
E.90 | Power supply voltage is extremely low. | Turn off power and check voltage. |
|
|
| ||||
E.91 | Power supply voltage is extremely high. | Turn off power and check voltage. |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
64