Brother BAS-326F-0, BAS-311F-L, BAS-311F-0 instruction manual Head position switch cord connection

Page 78

14. TROUBLESHOOTING

Problem

Cause

 

Check

 

Remedy

Page

 

 

 

 

 

 

Unstable upper thread length

Unstable needle up stop position

Machine does not operated when power is turned on and foot switch is depressed.

Improper tension and height of thread take-up spring

Improper adjustment of sub tension

Needle up stop position fluctuates.

Fixed knife is blunt.

Electrical trouble

Head position switch does not work.

Thread take-up spring tension and height

sub tension

See “Unstable needle up stop position”.

Fixed knife blade

Refer to the details for [E.22] in the error code table.

Head position switch cord connection.

Switching plate position.

Head position switch is broken.

 

Adjust the tension and

25

 

height of the thread take-

 

 

up spring.

 

 

 

 

 

Adjust the sub tension.

 

 

 

 

 

 

 

 

 

 

Sharpen or replace the fixed knife.

63

Check if the cord is 11 13 disconnected.

 

Adjust the position of the

7

 

switching plate.

 

 

 

 

 

Replace the head position switch.

BAS-311F-0, 311F-L, 326F-0

71

Image 78
Contents BAS-326F-0 Safety Instructions Safety indications and their meaningsInstallation Environmental requirementsCleaning SewingMaintenace and inspection Direction of operation Frame side cover Contents Changing Special Functions Name of Major Parts Specifications BAS-311F-L *3 a BAS-326F-0 *4 aInstallation Table processing diagram PositioningInstalling the control box Installing the rubber cushions Installing the oil panInstalling the cushions Installing the switching plateInstalling the machine head Tilting the sewing machine head 1170S Connecting the ground wire Connecting the cords Installing the operation panelBAS-311F-0 Solenoid type only ORG Installing the belt cover Installing the foot switchInstalling the spool stand Installing the eye guard Installing the programmer option Installing the feed base cover supports BAS-311F-L, 326F-0 Installing the X feed base cover BAS-311F-L, 326F-0Connecting the tubes pneumatic type only When installing to the underside of the work table When installing to a beamLubrication Lubrication pointsBAS-326F-0 Installing the needle Correct OperationSelecting the needle and thread Threading the upper thread Winding the lower thread Replacing the bobbin case and threading the thread Sewing conditions and thread tensionLower thread tension Using the Operation Panel Explanation of panel110 Using the floppy disk Compatible types of floppy diskSetting the floppy disk How to use the cleaning diskClearing the error Using the program R/W Read/Write switchIf an error message is displayed To Read a pattern to memoryUsing the Test switch Checking the sewing pattern Resuming operation from a stopping poingUsing the emergency stop switch Continuing sewing from a stopping pointAdjusting the sewing Speed control Changing the X-SCALE and Y-SCALE settingsUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Sewing Before starting sewingSewing operation 1230S Lubrication Cleaning and InspectionCleaning the rotary hook Draining the oilCleaning the eye guard Cleaning the control box air inlet portCleaning the air holes of belt cover and frame side cover Checking the needleStandard Adjustments Adjusting the needle bar heightAdjusting the needle bar lift amount Adjusting the needle clearance Adjusting the driver needle guardAdjusting the shuttle race thread guide Adjusting the movable knife Replacing the movable and fixed knives AbcdAdjusting the presser foot Changing the presser foot lift Adjusting presser foot lift to 3 5mmAdjusting presser foot lift to 5 8 mm Standard presser foot lift is 3 mm max mmAdjusting the wiper For vertical wiper standardAdjusting the two-step work clamp lift amount BAS-311F-0 Solenoid typeBAS-326F-0 Adjusting the needle up stop position Checking the input sensor and DIP switch input Clearing all memory settings Checking the input voltageDIP Switch Panel DIP switch functionsDipswitch BAS-311F-L onlyDIP switches inside the control box DIP Switch CDipswitch Changing Special Functions and Using the Memory Switches If memo-0E is ON, the work clamp opens and closes twice Switch No When on Memo-10 Main circuit board instead of the voltage Switch No Possible Units Error Codes Can not backup data. Control PCB Turn off power and check connector P20 Gauge Parts List According to Subclasses Bobbin case assy S59221-001 LC Troubleshooting Incorrect needle and rotary hook timing Adjust the needle bar lift Amount Adjust the position Head position switch cord connection Options WP stitch device Automatic bobbin changerPlay prevention work clamp 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone