KitchenAid W10284348A Make Gas Connection, Complete Connection, Closed valve Open valve

Page 15

3.Pull tube to ensure it is secured.

Water supply tubing to range

Sink

Water supply connection

Yellow

WATER

IN

 

Water supply tubing

Blue

Shutoff

to cold water supply

WATER

valve

 

OUT

 

 

 

 

Filter

4.Route flexible codes approved water supply line through undersink cabinet and oven cabinet cutout.

5.Connect the flexible codes approved water supply line to the range copper tubing, using a ¼" to ¼" water supply union.

B

 

F

 

C

D

 

 

 

A

 

E

A. To home water supply B. Rear of cabinet cutout

C. Flexible codes approved water supply line from home water supply

D. ¼" to ¼" water supply union (supplied in water filter kit) E. Oven copper tubing

F. Range front

6.Turn on water supply.

7.Check all connections for leaks.

NOTE: No flushing or conditioning of the water filter is required prior to use.

Make Gas Connection

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

1.Assemble flexible connector from gas supply pipe to pressure regulator located in the middle rear of the range.

2.Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters (see B and G in the following illustration).

3.Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters.

4.Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to attach the flexible connector to the adapters. Check that connector is not kinked.

A B C

D

E

 

H G

F

A. Gas pressure regulator

E. Manual gas shutoff valve

B. Use pipe-joint compound.

F. ½" or ¾" gas pipe

 

C. Adapter (must have ½" male

G. Use pipe-joint compound.

pipe thread)

H. Adapter

 

D. Flexible connector

 

 

Complete Connection

1.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.

A

B

A. Closed valve

B. Open valve

15

Image 15
Contents W10284348A Commercial Style Dual Fuel Convection RangeTable of Contents Your safety and the safety of others are very important Range SafetyTools and Parts Installation RequirementsHigh Altitude Conversion Mobile Home Additional Installation RequirementsProduct Dimensions 30 76.2 cm models Location RequirementsCabinet Dimensions 36 91.4 cm models48 121.9 cm models Water Filtration System Location Requirements Water Supply RequirementsElectrical Requirements U.S.A. Only Wire receptacle 10-50R If connecting to a 4-wire systemIf connecting to a 3-wire system Wire receptacle 14-50RGas Supply Requirements Type of GasGas Supply Line Gas Pressure Regulator Installation InstructionsGas Supply Pressure Testing Unpack RangeInstall Anti-Tip Bracket Install Optional BackguardElectrical Connection U.S.A. Only 30 76.2 cm and 36 91.4 cm ModelsUL listed strain relief Wire connection Power supply cord Block screw Power supply cordGround-link screw Ground link bent away from range Install Water Filtration System on some models Closed valve Open valve Pipe thread Adapter Flexible connectorMake Gas Connection Complete ConnectionInstall Grill Grease Trays Verify Anti-Tip Bracket LocationLevel Range Install Griddle Install Burner Heads and CapsElectronic Ignition System If burners do not light properly Initial Lighting and Gas Flame AdjustmentsTo Adjust Flame Height Check Operation of Cooktop BurnersCheck Operation of Ovens Reinstall KickplateComplete Installation If you need Assistance or ServiceTo Convert Gas Pressure Regulator Gas Supply Pressure TestingGAS Conversions LP Gas ConversionComplete Installation To Convert Grill Burner on some modelsBurner orifice spud Grill orifice hood Natural Gas Conversion Burner cap Burner headBurner head Gas opening Burner base Size stamp Strip Circuits Wiring Diagrams Cooktop SchematicsBurner Cooktop AC Drive Motor Relay Coil Relay Contact Left OvenBK 48 121.9 cm Oven Schematic for Kdrs ModelsL2 L1 Left Oven 48 121.9 cm Oven Schematic for Kdru ModelsVotre sécurité et celle des autres est très importante Sécurité DE LA CuisinièreOutils nécessaires Exigences D’INSTALLATIONOutillage et pièces Pièces fourniesExigences demplacement Pièces nécessairesConversion pour utilisation en haute altitude Dimensions du produit Modèles de 30 76,2 cm Modèles de 36 91,4 cmModèles de 48 121,9 cm ½ 3,8 cm J 7,6 cm K 12,7 cm Exigences demplacement du système de Filtration de leauDimensions du placard Configuration dinstallation typiqueAlimentation en eau par osmose inverse Spécifications de l’installation électriqueSpécifications de l’alimentation en eau Spécifications de lalimentation en gazDébit thermique des brûleurs Altitude Type de gazCanalisation de gaz DétendeurDéballage de la cuisinière Instructions D’INSTALLATIONInstallation du dosseret facultatif Installation de la bride antibasculementInstallation du modèle de filtre à eau W10049700 Installation du système de filtration de leauRaccordement à la sortie du filtre à eau bleu Raccordement à l’alimentation en eau du domicileRaccordement à lentrée du filtre à eau jaune Si lon doit dégager le tuyauAchever le raccordement Vérification de lemplacement de la bride AntibasculementRaccordement au gaz Réglage de laplomb de la cuisinièreInstallation des plateaux à graisse du gril Allumage initial et réglages des flammes de gaz Installation de la plaque à frireInstallation des têtes et des chapeaux de brûleur Système dallumage électroniqueBrûleur à double flamme Si les brûleurs ne sallument pas correctementHauteur de flamme Réglage de la taille des flammesContrôle du fonctionnement du/des fours Réinstallation du garde-piedsAchever linstallation Si vous avez besoin d’assistance ou de serviceChapeau de louverture daccès Position LP Joint détanchéité Conversions Pour Changement DE GAZConversion pour lalimentation au propane Conversion du détendeurConversion des brûleurs de surface Conversion du brûleur du gril sur certains modèlesGicleur de brûleur Injecteur femelle du gril Chapeau de louverture daccès Achever linstallationConversion pour lalimentation au gaz naturel Ouverture de la virole de réglage VisMarquage pour identification De la taille Chapeau de brûleurOuverture de gaz Base du brûleur Achever linstallation Schémas des circuits du four Schémas de la table de cuisson Schéma de câblageLégende Schéma du four 48 121,9 cm pour les modèles Kdrs Tableau de commande ClavierLégende Porte du four fermée Schéma du four 48 121,9 cm pour les modèles KdruAll rights reserved