KitchenAid W10284348A Water Filtration System Location Requirements, Water Supply Requirements

Page 7

Water Filtration System Location

Requirements

(on some models)

For best results, do not install the water filtration system outside, or in extreme hot or cold temperatures. Temperature of water supply to the water filtration system must be between 40°F/4°C and 100°F/38°C. Do not install on hot water supply line.

Locate the water filtration system near the cold water supply pipe under the kitchen sink to filter cold water.

Make sure that the water filter assembly is installed in the upright position.

It will be necessary to drill a ½" (1.3 cm) minimum diameter hole in the upper right or left rear corner of the side wall of the cabinet under the sink to route the water supply tubing through to the range.

Depending on your installation configuration, more routing holes may be required.

Coil enough flexible codes approved water supply tubing behind the range to allow for the connection to the range to be made behind the range prior to setting the range in place.

Typical Installation Configuration

NOTE: For unique installations contact a licensed plumber.

In Massachusetts a licensed plumber is required and the Commonwealth of Massachusetts Plumbing Code 248-CMR shall be adhered to.

Cold water

supply

Hot Cold

Filter

 

assembly

 

location

Water Supply Requirements

A cold water supply with water pressure between 30 and 120 psi (207 and 827 kPa) is required to operate the steam feature. In Massachusetts, plumbing code 248 CMR 3.00 and 10.00 must be followed and a licensed plumber shall be used. If you have questions about your water pressure call a licensed, qualified plumber.

Reverse Osmosis Water Supply

IMPORTANT: The pressure of the water supply coming out of a reverse osmosis system going to the water inlet valve of the range needs to be between 30 and 120 psi (207 and 827 kPa).

If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 psi (276 kPa).

If the water pressure to the reverse osmosis system is less than

40 psi (276 kPa):

Check to see whether the sediment filter in the reverse osmosis system is blocked. Replace the filter if necessary.

Allow the storage tank on the reverse osmosis system to refill after heavy usage.

If you have questions about your water pressure, call a licensed, qualified plumber.

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Do not use an extension cord.

Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from: National Fire Protection Association

One Batterymarch Park Quincy, MA 02269.

WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Electrical Connection

To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located on the right vertical surface of the oven door frame. Refer to the figures in the “Product Dimensions” section of the “Location Requirements” section.

Use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.

Range Rating*

 

Specified Rating of Power

 

 

Supply Cord Kit and

 

 

Circuit Protection

 

 

 

 

120/240 Volts

120/208 Volts

Amps

Range Size

 

 

 

 

8.8 - 16.5 kW

7.8 - 12.5 kW

40 or 50**

30” (76.2 cm),

 

 

 

36” (91.4 cm)

16.6 - 22.5 kW

12.6 - 18.5 kW

50

48” (121.9 cm)

 

 

 

 

*The NEC calculated load is less than the total connected load listed on the model/serial rating plate.

**If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening.

A circuit breaker is recommended.

Wire sizes and connections must conform with the rating of the range.

The Tech Sheet is located in the console in a clear plastic bag.

7

Image 7
Contents W10284348A Commercial Style Dual Fuel Convection RangeTable of Contents Your safety and the safety of others are very important Range SafetyTools and Parts Installation RequirementsHigh Altitude Conversion Mobile Home Additional Installation RequirementsProduct Dimensions 30 76.2 cm models Location Requirements36 91.4 cm models Cabinet Dimensions48 121.9 cm models Water Supply Requirements Water Filtration System Location RequirementsElectrical Requirements U.S.A. Only Wire receptacle 10-50R If connecting to a 4-wire systemIf connecting to a 3-wire system Wire receptacle 14-50RType of Gas Gas Supply RequirementsGas Supply Line Gas Pressure Regulator Installation InstructionsGas Supply Pressure Testing Unpack RangeInstall Anti-Tip Bracket Install Optional Backguard30 76.2 cm and 36 91.4 cm Models Electrical Connection U.S.A. OnlyUL listed strain relief Block screw Power supply cord Wire connection Power supply cordGround-link screw Ground link bent away from range Install Water Filtration System on some models Closed valve Open valve Pipe thread Adapter Flexible connectorMake Gas Connection Complete ConnectionVerify Anti-Tip Bracket Location Install Grill Grease TraysLevel Range Install Burner Heads and Caps Install GriddleElectronic Ignition System If burners do not light properly Initial Lighting and Gas Flame AdjustmentsTo Adjust Flame Height Check Operation of Cooktop BurnersCheck Operation of Ovens Reinstall KickplateComplete Installation If you need Assistance or ServiceTo Convert Gas Pressure Regulator Gas Supply Pressure TestingGAS Conversions LP Gas ConversionTo Convert Grill Burner on some models Complete InstallationBurner orifice spud Grill orifice hood Burner cap Burner head Natural Gas ConversionBurner head Gas opening Burner base Size stamp Strip Circuits Cooktop Schematics Wiring DiagramsBurner Cooktop AC Drive Motor Relay Coil Relay Contact Left OvenBK 48 121.9 cm Oven Schematic for Kdrs ModelsL2 L1 Left Oven 48 121.9 cm Oven Schematic for Kdru ModelsVotre sécurité et celle des autres est très importante Sécurité DE LA CuisinièreOutils nécessaires Exigences D’INSTALLATIONOutillage et pièces Pièces fourniesPièces nécessaires Exigences demplacementConversion pour utilisation en haute altitude Modèles de 36 91,4 cm Dimensions du produit Modèles de 30 76,2 cmModèles de 48 121,9 cm ½ 3,8 cm J 7,6 cm K 12,7 cm Exigences demplacement du système de Filtration de leauDimensions du placard Configuration dinstallation typiqueAlimentation en eau par osmose inverse Spécifications de l’installation électriqueSpécifications de l’alimentation en eau Spécifications de lalimentation en gazDébit thermique des brûleurs Altitude Type de gazCanalisation de gaz DétendeurDéballage de la cuisinière Instructions D’INSTALLATIONInstallation du dosseret facultatif Installation de la bride antibasculementInstallation du modèle de filtre à eau W10049700 Installation du système de filtration de leauRaccordement à la sortie du filtre à eau bleu Raccordement à l’alimentation en eau du domicileRaccordement à lentrée du filtre à eau jaune Si lon doit dégager le tuyauAchever le raccordement Vérification de lemplacement de la bride AntibasculementRaccordement au gaz Réglage de laplomb de la cuisinièreInstallation des plateaux à graisse du gril Allumage initial et réglages des flammes de gaz Installation de la plaque à frireInstallation des têtes et des chapeaux de brûleur Système dallumage électroniqueBrûleur à double flamme Si les brûleurs ne sallument pas correctementHauteur de flamme Réglage de la taille des flammesContrôle du fonctionnement du/des fours Réinstallation du garde-piedsAchever linstallation Si vous avez besoin d’assistance ou de serviceChapeau de louverture daccès Position LP Joint détanchéité Conversions Pour Changement DE GAZConversion pour lalimentation au propane Conversion du détendeurConversion du brûleur du gril sur certains modèles Conversion des brûleurs de surfaceGicleur de brûleur Injecteur femelle du gril Chapeau de louverture daccès Achever linstallationConversion pour lalimentation au gaz naturel Ouverture de la virole de réglage VisChapeau de brûleur Marquage pour identification De la tailleOuverture de gaz Base du brûleur Achever linstallation Schémas des circuits du four Schémas de la table de cuisson Schéma de câblageLégende Schéma du four 48 121,9 cm pour les modèles Kdrs Tableau de commande ClavierLégende Porte du four fermée Schéma du four 48 121,9 cm pour les modèles KdruAll rights reserved