KitchenAid W10284348A GAS Conversions, LP Gas Conversion, To Convert Gas Pressure Regulator

Page 20

GAS CONVERSIONS

IMPORTANT: Gas conversions from Natural gas to LP gas must be done by a qualified installer.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

LP Gas Conversion

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

1.Turn the manual shutoff valve to the closed position.

2.Unplug range or disconnect power.

B

A

C

A. To range

B. Shutoff valve (closed position)

C. Gas supply line

To Convert Gas Pressure Regulator

1.Remove the access cap by using a wrench, turning the access cap counterclockwise.

2.Remove spring retainer from the cap by pushing against the flat side of the spring retainer. Look at the spring retainer to locate the “NAT” or “LP” position. Turn over the spring retainer so the “LP” is showing on the bottom. Snap the spring retainer back into the cap. Reinstall the cap onto the regulator.

A

B

E

D

C

A. Access cap

 

D. LP position

B. Gasket

 

E. NAT position

C. Gas pressure regulator

3.Test the gas pressure regulator and gas supply line.

The regulator must be checked at a minimum 1" (2.5 cm) water column above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:

LP Gas:

Minimum pressure 11" (27.9 cm) WCP Maximum pressure 14" (35.5 cm) WCP.

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate.

Line pressure testing above ½ psi gauge (14" WCP)

The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

Line pressure testing at ½ psi gauge (14" WCP) or lower

The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

To Convert Surface Burners

1.If installed, remove the burner grates.

2.Remove burner cap.

3.Remove the burner head.

NOTE: A ⁷⁄₈" socket must be used to remove the burner head of the large dual burners.

20

Image 20
Contents Commercial Style Dual Fuel Convection Range W10284348ATable of Contents Range Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsMobile Home Additional Installation Requirements Product Dimensions 30 76.2 cm modelsLocation Requirements High Altitude Conversion48 121.9 cm models Cabinet Dimensions36 91.4 cm models Electrical Requirements U.S.A. Only Water Filtration System Location RequirementsWater Supply Requirements If connecting to a 4-wire system If connecting to a 3-wire systemWire receptacle 14-50R Wire receptacle 10-50RGas Supply Line Gas Supply RequirementsType of Gas Installation Instructions Gas Supply Pressure TestingUnpack Range Gas Pressure RegulatorInstall Optional Backguard Install Anti-Tip BracketUL listed strain relief Electrical Connection U.S.A. Only30 76.2 cm and 36 91.4 cm Models Ground-link screw Ground link bent away from range Wire connection Power supply cordBlock screw Power supply cord Install Water Filtration System on some models Pipe thread Adapter Flexible connector Make Gas ConnectionComplete Connection Closed valve Open valveLevel Range Install Grill Grease TraysVerify Anti-Tip Bracket Location Electronic Ignition System Install GriddleInstall Burner Heads and Caps Initial Lighting and Gas Flame Adjustments To Adjust Flame HeightCheck Operation of Cooktop Burners If burners do not light properlyReinstall Kickplate Complete InstallationIf you need Assistance or Service Check Operation of OvensGas Supply Pressure Testing GAS ConversionsLP Gas Conversion To Convert Gas Pressure RegulatorBurner orifice spud Grill orifice hood Complete InstallationTo Convert Grill Burner on some models Burner head Gas opening Burner base Natural Gas ConversionBurner cap Burner head Size stamp Strip Circuits Burner Cooktop Wiring DiagramsCooktop Schematics AC Drive Motor Relay Coil Relay Contact 48 121.9 cm Oven Schematic for Kdrs Models Left OvenBKL2 L1 48 121.9 cm Oven Schematic for Kdru Models Left OvenSécurité DE LA Cuisinière Votre sécurité et celle des autres est très importanteExigences D’INSTALLATION Outillage et piècesPièces fournies Outils nécessairesConversion pour utilisation en haute altitude Exigences demplacementPièces nécessaires Modèles de 48 121,9 cm Dimensions du produit Modèles de 30 76,2 cmModèles de 36 91,4 cm Exigences demplacement du système de Filtration de leau Dimensions du placardConfiguration dinstallation typique ½ 3,8 cm J 7,6 cm K 12,7 cmSpécifications de l’installation électrique Spécifications de l’alimentation en eauSpécifications de lalimentation en gaz Alimentation en eau par osmose inverseType de gaz Canalisation de gazDétendeur Débit thermique des brûleurs AltitudeInstructions D’INSTALLATION Installation du dosseret facultatifInstallation de la bride antibasculement Déballage de la cuisinièreInstallation du système de filtration de leau Installation du modèle de filtre à eau W10049700Raccordement à l’alimentation en eau du domicile Raccordement à lentrée du filtre à eau jauneSi lon doit dégager le tuyau Raccordement à la sortie du filtre à eau bleuVérification de lemplacement de la bride Antibasculement Raccordement au gazRéglage de laplomb de la cuisinière Achever le raccordementInstallation des plateaux à graisse du gril Installation de la plaque à frire Installation des têtes et des chapeaux de brûleurSystème dallumage électronique Allumage initial et réglages des flammes de gazSi les brûleurs ne sallument pas correctement Hauteur de flammeRéglage de la taille des flammes Brûleur à double flammeRéinstallation du garde-pieds Achever linstallationSi vous avez besoin d’assistance ou de service Contrôle du fonctionnement du/des foursConversions Pour Changement DE GAZ Conversion pour lalimentation au propaneConversion du détendeur Chapeau de louverture daccès Position LP Joint détanchéitéGicleur de brûleur Injecteur femelle du gril Conversion des brûleurs de surfaceConversion du brûleur du gril sur certains modèles Achever linstallation Conversion pour lalimentation au gaz naturelOuverture de la virole de réglage Vis Chapeau de louverture daccèsOuverture de gaz Base du brûleur Marquage pour identification De la tailleChapeau de brûleur Achever linstallation Schémas des circuits du four Schéma de câblage Schémas de la table de cuissonLégende Tableau de commande Clavier Schéma du four 48 121,9 cm pour les modèles KdrsLégende Schéma du four 48 121,9 cm pour les modèles Kdru Porte du four ferméeAll rights reserved